Sponsored Content
UNIX Standards and Benchmarks UNIX & LINUX Benchmarks (Version 3.11) Linux Benchmarks Dell Dual Xeon PowerEdge 4600 Post 41371 by tnorth on Friday 3rd of October 2003 11:49:09 PM
Old 10-04-2003
Dell Dual Xeon PowerEdge 4600

Notes:



System Configuration: [i686] Dell Computer Corporation PowerEdge 4600 (4 X Intel(R) XEON(TM) CPU 2.00GHz
1988.782 MHz) hyperthreaded
System clock frequency: 99.0827 MHz
Memory size (approximate): 2559 Megabytes

========================= CPUs ========================

CPU # CPU MHz CACHE (KB) Bogomips
------- --------- ------------ ----------
0 1988.782 512 KB 3944.04
3970.35
1 1988.782 512 KB
2 1988.782 512 KB
3 1988.782 512 KB 3970.35
3970.35


PCI RAID Dell Computer Corporation PowerEdge Expandable RAID Controller 3/Di (rev 01)
PCI SCSI Adaptec RAID
RAID5 across 5 disks.

Results:
BYTE UNIX Benchmarks (Version 3.11)
System -- Linux box .
unknown
Start Benchmark Run: Wed Sep 10 16:13:25 EDT 2003
13 interactive users.
Dhrystone 2 without register variables 2804051.1 lps (10 secs, 6 samples)
Dhrystone 2 using register variables 2779392.5 lps (10 secs, 6 samples)
Arithmetic Test (type = arithoh) 10609125.6 lps (10 secs, 6 samples)
Arithmetic Test (type = register) 495673.6 lps (10 secs, 6 samples)
Arithmetic Test (type = short) 329765.3 lps (10 secs, 6 samples)
Arithmetic Test (type = int) 493445.2 lps (10 secs, 6 samples)
Arithmetic Test (type = long) 495279.2 lps (10 secs, 6 samples)
Arithmetic Test (type = float) 447996.4 lps (10 secs, 6 samples)
Arithmetic Test (type = double) 448015.6 lps (10 secs, 6 samples)
System Call Overhead Test 198333.6 lps (10 secs, 6 samples)
Pipe Throughput Test 282941.1 lps (10 secs, 6 samples)
Pipe-based Context Switching Test 104133.0 lps (10 secs, 6 samples)
Process Creation Test 3907.1 lps (10 secs, 6 samples)
Execl Throughput Test 1299.8 lps (9 secs, 6 samples)
File Read (10 seconds) 856057.0 KBps (10 secs, 6 samples)
File Write (10 seconds) 184249.0 KBps (10 secs, 6 samples)
File Copy (10 seconds) 37179.0 KBps (10 secs, 6 samples)
File Read (30 seconds) 925.0 KBps (30 secs, 2 samples)
File Write (30 seconds) 427.0 KBps (30 secs, 2 samples)
File Copy (30 seconds) 1.0 KBps (30 secs, 2 samples)
C Compiler Test 839.7 lpm (60 secs, 3 samples)
Shell scripts (1 concurrent) 1809.0 lpm (60 secs, 3 samples)
Shell scripts (2 concurrent) 1354.3 lpm (60 secs, 3 samples)
Shell scripts (4 concurrent) 930.0 lpm (60 secs, 3 samples)
Shell scripts (8 concurrent) 497.0 lpm (60 secs, 3 samples)
Dc: sqrt(2) to 99 decimal places 55201.8 lpm (60 secs, 6 samples)
Recursion Test--Tower of Hanoi 48568.8 lps (10 secs, 6 samples)



INDEX VALUES
TEST BASELINE RESULT INDEX

Arithmetic Test (type = double) 2541.7 448015.6 176.3
Dhrystone 2 without register variables 22366.3 2804051.1 125.4
Execl Throughput Test 16.5 1299.8 78.8
File Copy (30 seconds) 179.0 1.0 0.0
Pipe-based Context Switching Test 1318.5 104133.0 79.0
Shell scripts (8 concurrent) 4.0 497.0 124.2
=========
SUM of 6 items 583.6
AVERAGE 97.3
 

8 More Discussions You Might Find Interesting

1. Linux Benchmarks

Dell Poweredge 2400 / 533

CPU/Speed: Dual PIII 533 Ram: 256Mb PC133 Motherboard: Unknown, Intel Chipset Cache: 256k on board Controller: PARC Raid 2/Si, AIC-7880U Disk: 30Gb RAID 5 Load: 1 user. Clean boot, init 5 but X-Windows not loaded. Kernel: See Benchmarks. pgms: gcc 3.2.3 ... (2 Replies)
Discussion started by: Garp
2 Replies

2. Solaris

Installing Solaris 10 on Dell PowerEdge 2800

hi, i am trying to install solaris 10 (on 4 cd's downloaded from the sun website) on my dell poweredge 2800 server. 2 xeon processors, 2GB of RAM and 2 NICS, 73 GB SCSI (maxtor ultra320, 3.5 series), i can give more details on request... the installation crashes when trying to detect the NICS... (0 Replies)
Discussion started by: xinugeek
0 Replies

3. Filesystems, Disks and Memory

Linux and Dell 1500sc Poweredge Server

Does anybody no how to get around the fact that the Red Hat installation does not see the SCSI hard drives. It lets you manually pick the proper device, but still fails saying no drive detected (or something to that effect). I was going to install windows 2003 Server and use VMware...but again,... (1 Reply)
Discussion started by: Fatflea
1 Replies

4. UNIX for Dummies Questions & Answers

Stange problem Dell PowerEdge 1950/ Boradcom Netextreme NIC

I have 2 Dell Poweredge 1950 servers running . I have been having intermittent performance issues with the NIC cards on one of them. The two servers are identical and are running the same operating system. The server that has the issue is on the DMZ on a a static IP and is hosting a website. ... (0 Replies)
Discussion started by: skotapal
0 Replies

5. SCO

Continueing relyability problems with SCO 6.0 on Dell Poweredge 1800 with PERC DC4.

Hello all, I'am experiencing weird relyability problems with a SCO 6.0 Openserver server that runs on a Dell Poweredge 1800 equipped with a PERC DC4 raid controller and 4 36 GB 15 K rpm hot swappable scsi harddisks. It runs a RAID 10 configuration. It uses the mega hba, Revision 8.03a Release... (1 Reply)
Discussion started by: frederik1
1 Replies

6. Programming

/dev/mem on Dell Poweredge

Hi, I have a C++ program to access /dev/mem and retrieve details like Vendor, Manufacturer details of the motherboard. This works fine on all the machines except for on Dell Poweredge 2850,1950... machines. I receive a 'EFAULT' when I try to access /dev/mem on these servers. I suspect some... (1 Reply)
Discussion started by: ragisreekanth
1 Replies

7. Linux Benchmarks

HP ML 350 dual Xeon 3.2GHz

CPU: dual Xeon 3.2 GHz Ram: 1Gig Motherboard: Bus: 800MHz Cache: 1MB Controller:Smart Array 641 Disk: UltraSCSI 320 Load: Kernel:2.6.9-1.667smp Kernel ELF?: yes pgms: compiled with gcc 3.4.3 BYTE UNIX Benchmarks (Version 3.11) System -- Linux ford 2.6.9-1.667smp #1 SMP... (0 Replies)
Discussion started by: migurus
0 Replies

8. SCO

Dell PowerEdge 2600 tape backup

I was asked to get a Dell PowerEdge 2600 server, out of warranty, running SCO 3.2v5.06 to perform a full backup. I spent hours researching and preparing a strategy only to fail on-site. The only device names in /dev for a tape drive were /dev/xStp0 /dev/xcdt0 /dev/xct0 ... (6 Replies)
Discussion started by: ezlarry
6 Replies
BNX(4)							   BSD Kernel Interfaces Manual 						    BNX(4)

NAME
bnx -- Broadcom NetXtreme II 10/100/1000 Ethernet device SYNOPSIS
bnx* at pci? brgphy* at mii? DESCRIPTION
The bnx driver supports Broadcom's NetXtreme II product family, such as the BCM5706 PCI-X and BCM5708-BCM5709 PCI Express Ethernet con- trollers, which includes the following: o Dell PowerEdge 1950 integrated BCM5708 NIC (10/100/1000baseT) o Dell PowerEdge 2950 integrated BCM5708 NIC (10/100/1000baseT) o Dell PowerEdge M710 integrated BCM5709S NIC (1000baseSX) o HP NC370F PCI-X Multifunction Gigabit server adapter (1000baseSX) o HP NC370T PCI-X Multifunction Gigabit server adapter (10/100/1000baseT) o HP NC373F PCI Express Multifunction Gigabit server adapter (1000baseSX) o HP NC373i PCI Express Multifunction Gigabit embedded server adapter (10/100/1000baseT) o HP NC380T PCI Express Dual Port Multifunction Gigabit server adapter (10/100/1000baseT) o IBM xSeries 3550 integrated BCM5708 NIC (10/100/1000baseT) o IBM xSeries 3650 integrated BCM5708 NIC (10/100/1000baseT) The NetXtreme II product family is composed of various Converged NIC (or CNIC) Ethernet controllers which support a TCP Offload Engine (TOE), Remote DMA (RDMA), and iSCSI acceleration, in addition to standard L2 Ethernet traffic, all on the same controller. The following features are supported in the bnx driver under NetBSD: IPv4 receive IP/TCP/UDP checksum offload Jumbo frames (up to 9022 bytes) VLAN tag insertion Interrupt coalescing 10/100/1000Mbps operation in full-duplex mode 10/100Mbps operation in half-duplex mode The bnx driver supports the following media types: autoselect Enable autoselection of the media type and options. The user can manually override the autoselected mode via ifconfig(8). 10baseT/UTP Set 10Mbps operation. The ifconfig(8) mediaopt option can also be used to select either full-duplex or half-duplex modes. 100baseTX Set 100Mbps (Fast Ethernet) operation. The ifconfig(8) mediaopt option can also be used to select either full-duplex or half-duplex modes. 1000baseTX Set 1000baseTX operation over twisted pair. Only full-duplex mode is supported. 1000baseSX Set 1000Mbps (Gigabit Ethernet) operation. Both full-duplex and half-duplex modes are supported. 2500baseSX Set 2500Mbps operation. Only full-duplex mode is supported. The bnx driver supports the following media options: full-duplex Force full duplex operation. half-duplex Force half duplex operation. For more information on configuring this device, see ifconfig(8). SEE ALSO
arp(4), brgphy(4), ifmedia(4), intro(4), mii(4), netintro(4), pci(4), ifconfig(8) HISTORY
The bnx device driver first appeared in NetBSD 4.0. BSD
December 10, 2010 BSD
All times are GMT -4. The time now is 05:04 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy