From SMS

Boot the client to SMS then select menu item 5. Select Boot Options then select 4. SAN zoning. This will result in the adapters being shown. Select each adapter in turn which will lead to the panel which shows that the adapter is open. The adapter should now be logged into the respective VIO server in the lsmap screen.
 

10 More Discussions You Might Find Interesting

1. AIX

Problem mapping LUN disk from VIOS to the LPAR

Hello guys, It would be so nice of you if someone can provide me with these informations. 1) My SAN group assigned 51G of LUN space to the VIO server.I ran cfgdev to discover the newly added LUN. Unfortunately most of the disks that are in VIO server is 51G. How would I know which is the newly... (3 Replies)
Discussion started by: solaix14
3 Replies

2. AIX

VIOS to lpar Mapping

Hello, I have created mapping of 2 virtual adapters for Lpars using following command: mkvdev -vdev ipanalyzerlv1 -vadapter vhost11 mkvdev -vdev ipanalyzerlv -vadapter vhost13 The above two commands were succesfull but when I want to map the third virtual device to the same Lpar than... (3 Replies)
Discussion started by: Vit0_Corleone
3 Replies

3. AIX

Anyone using NPIV?

Is anyone here using NPIV with AIX? If you are, what type of switch are you connected to? Also, please share some impressions of NPIV over traditional port-to-port LUN assignments. We are looking to move to NPIV and need some convincing argume... I mean information. (2 Replies)
Discussion started by: kah00na
2 Replies

4. AIX

Migrating hdisks from vscsi to NPIV with powerpath

Hi All, I'm preparing to migrate some servers from vscsi to pass-thru NPIV. I am planning to have the SAN team move the exact LUNs from vio1/vio2 to those two VWWN through NPIV. My question is on the partition itself.. right now, let's say I have hdisk0/1/2/3/4 that are part of datavg. They... (2 Replies)
Discussion started by: lapfrank
2 Replies

5. AIX

Vscsi and npiv on same adapter

Hi, I want to change from vscsi to npiv. Is it possible to use both on the same adapter, so we can change the systems one by one, or must we place a second FC adapter in the VIO servers? Thanks, Ronald (2 Replies)
Discussion started by: ronaldm60
2 Replies

6. AIX

Few VIOS questions

Hi, I would like to ask you if you could help me to answer these questions. Please. How to check in vios, size all pv's and to what they are mapped to? How to chech on vios/hmc which PowerVM edition is used? Thank you. (7 Replies)
Discussion started by: phobus
7 Replies

7. AIX

NPIV mapping problem

Hello all I hope someone can help me with this. I have a single LPAR which is supplied a rootvg and datavg disk set from a dual VIO server configuration. I see dual path disks for all the datavg disks but only see one path for the rootvg disks. The client LPAR has the following: fcs0 ... (3 Replies)
Discussion started by: johnf
3 Replies

8. Shell Programming and Scripting

Creating unique mapping from multiple mapping

Hello, I do not know if this is the right title to use. I have a large dictionary database which has the following structure: where a b c d e are in English and p q r s t are in a target language., the two separated by the delimiter =. What I am looking for is a perl script which will take... (5 Replies)
Discussion started by: gimley
5 Replies

9. AIX

NPIV custom WWN

Hi All :) i would like to know if i can customize the WWN of the new VFC (NPIV). Or, if i must move the LPAR on another server with another FCS, i have to change the zoning?? Thanks in advance. Mario ---------- Post updated 09-21-12 at 02:51 AM ---------- Previous update was 09-20-12 at... (1 Reply)
Discussion started by: Zio Bill
1 Replies

10. AIX

VIOS IP address - separate vlan for vios servers ?

Hello, Lets say for simplicity that I do not use any vlan config inside my server - one lpar group use hea physical port1, another group hea physical port2. Physical port1 configured as vlan1 on external switch, physical port2 as vlan2. What is the common practice - should I isolate my vios... (0 Replies)
Discussion started by: vilius
0 Replies
bt-adapter(1)							    bluez-tools 						     bt-adapter(1)

NAME
bt-adapter - a bluetooth adapter manager SYNOPSIS
bt-adapter [OPTION...] Help Options: -h, --help Application Options: -l, --list -a, --adapter=<name|mac> -i, --info -d, --discover --set <property> <value> DESCRIPTION
This utility is used to manage Bluetooth adapters. You can list all available adapters, show information about adapter, change adapter properties or discover remote devices. OPTIONS
-h, --help Show help -l, --list List all available adapters -a, --adapter <name|mac> Specify adapter to use by his Name or MAC address (if this option does not defined - default adapter used) -i, --info Show information about adapter (returns all properties) -d, --discover Discover remote devices (with remote device name resolving) --set <property> <value> Change adapter properties (see ADAPTER PROPERTIES section for list of available properties) ADAPTER PROPERTIES
string Address [ro] The Bluetooth adapter address (MAC). string Name [rw] The Bluetooth adapter friendly name. uint32 Class [ro] The Bluetooth class of device. boolean Powered [rw] Switch an adapter on or off. This will also set the appropiate connectable state. boolean Discoverable [rw] Switch an adapter to discoverable or non-discoverable to either make it visible or hide it. If the DiscoverableTimeout is set to a non-zero value then the system will set this value back to false after the timer expired. In case the adapter is switched off, setting this value will fail. boolean Pairable [rw] Switch an adapter to pairable or non-pairable. Note that this property only affects incoming pairing requests. uint32 PaireableTimeout [rw] The pairable timeout in seconds. A value of zero means that the timeout is disabled and it will stay in pareable mode forever. uint32 DiscoverableTimeout [rw] The discoverable timeout in seconds. A value of zero means that the timeout is disabled and it will stay in discoverable/limited mode forever. The default value for the discoverable timeout should be 180 seconds (3 minutes). boolean Discovering [ro] Indicates that a device discovery procedure is active. list UUIDs [ro] List of 128-bit UUIDs that represents the available local services. AUTHOR
Alexander Orlenko <zxteam@gmail.com>. SEE ALSO
bt-agent(1) bt-audio(1) bt-device(1) bt-input(1) bt-monitor(1) bt-network(1) bt-serial(1) 2010-08-16 bt-adapter(1)
All times are GMT -4. The time now is 08:22 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy