Sponsored Content
Operating Systems AIX Vscsi and npiv on same adapter Post 302553934 by ronaldm60 on Friday 9th of September 2011 08:11:36 AM
Old 09-09-2011
Vscsi and npiv on same adapter

Hi,

I want to change from vscsi to npiv. Is it possible to use both on the same adapter, so we can change the systems one by one, or must we place a second FC adapter in the VIO servers?


Thanks,

Ronald
 

10 More Discussions You Might Find Interesting

1. AIX

Anyone using NPIV?

Is anyone here using NPIV with AIX? If you are, what type of switch are you connected to? Also, please share some impressions of NPIV over traditional port-to-port LUN assignments. We are looking to move to NPIV and need some convincing argume... I mean information. (2 Replies)
Discussion started by: kah00na
2 Replies

2. AIX

Migrating hdisks from vscsi to NPIV with powerpath

Hi All, I'm preparing to migrate some servers from vscsi to pass-thru NPIV. I am planning to have the SAN team move the exact LUNs from vio1/vio2 to those two VWWN through NPIV. My question is on the partition itself.. right now, let's say I have hdisk0/1/2/3/4 that are part of datavg. They... (2 Replies)
Discussion started by: lapfrank
2 Replies

3. AIX

NPIV with 8Gb PCI Express Dual Port FC Adapter

All I am at a loss with a VIO server running ios 2.2.0.10-FP-24 SP-01. The VIO server is fitted with two 8Gb PCI Express Dual Port FC Adapters. However when I run the lsnports command only two of the adapter ports show as capable: $ lsnports name physloc ... (4 Replies)
Discussion started by: johnf
4 Replies

4. AIX

hdisk mapping to a vSCSi Adapter

Hello, I have a VIOS System and would like to do mapping some hdisks, hdisk160 until hdisk165 to a vSCSi Adapter. I try to do this in the oem_setup_env like the following: for i in $(lspv | grep hdisk* | awk {'print $1'}; do mkdev -V $i -p vhost20 done There where a mapping with... (4 Replies)
Discussion started by: torsten163
4 Replies

5. AIX

NPIV mapping problem

Hello all I hope someone can help me with this. I have a single LPAR which is supplied a rootvg and datavg disk set from a dual VIO server configuration. I see dual path disks for all the datavg disks but only see one path for the rootvg disks. The client LPAR has the following: fcs0 ... (3 Replies)
Discussion started by: johnf
3 Replies

6. AIX

NPIV custom WWN

Hi All :) i would like to know if i can customize the WWN of the new VFC (NPIV). Or, if i must move the LPAR on another server with another FCS, i have to change the zoning?? Thanks in advance. Mario ---------- Post updated 09-21-12 at 02:51 AM ---------- Previous update was 09-20-12 at... (1 Reply)
Discussion started by: Zio Bill
1 Replies

7. AIX

VIOS FC Mapping/NPIV questions

Please forgive me here as I don't fully understand what I am talking about here so if I use the wrong terminology please overlook me. We have multiple AIX LPARs on the managed system with two VIO Servers. A Co-Worker and I are trying to set up a new LPAR client (The guy that knows this is out)... (14 Replies)
Discussion started by: juredd1
14 Replies

8. AIX

How to put vscsi in available state?

Hello Friends, My question/problem is that I noticed 2 servers in my environment vscsi is showing up as defined (not available) or is defined and not showing the path to both vscsi's when ruining lspath command. I am new to AIX admin, work alone, and work in an small environment. My question is,... (12 Replies)
Discussion started by: Adnans2k
12 Replies

9. AIX

Devices.vscsi.disk ?

Hello, When I assigned CDROM from IVM (VIOS) to LPAR and then running cfgmgr i get the following message on the client lpar #cfgmgr cfgmgr: 0514-621 WARNING: The following device packages are required for device support but are not currently installed. devices.vscsi.disk searching... (0 Replies)
Discussion started by: filosophizer
0 Replies

10. AIX

Misconfiguration detected Adapter interface name en 3 Adapter offset 0

Hi, We had a hardware problem with an IBM System p5 server, with AIX 5.2 We restore from a tape the last backup we had, but the server does not boot up as expected. The server try to mount some directories from a storage, but could not comunicate with them, we check the FC and everything is... (12 Replies)
Discussion started by: trevian3969
12 Replies
bt-adapter(1)							    bluez-tools 						     bt-adapter(1)

NAME
bt-adapter - a bluetooth adapter manager SYNOPSIS
bt-adapter [OPTION...] Help Options: -h, --help Application Options: -l, --list -a, --adapter=<name|mac> -i, --info -d, --discover --set <property> <value> DESCRIPTION
This utility is used to manage Bluetooth adapters. You can list all available adapters, show information about adapter, change adapter properties or discover remote devices. OPTIONS
-h, --help Show help -l, --list List all available adapters -a, --adapter <name|mac> Specify adapter to use by his Name or MAC address (if this option does not defined - default adapter used) -i, --info Show information about adapter (returns all properties) -d, --discover Discover remote devices (with remote device name resolving) --set <property> <value> Change adapter properties (see ADAPTER PROPERTIES section for list of available properties) ADAPTER PROPERTIES
string Address [ro] The Bluetooth adapter address (MAC). string Name [rw] The Bluetooth adapter friendly name. uint32 Class [ro] The Bluetooth class of device. boolean Powered [rw] Switch an adapter on or off. This will also set the appropiate connectable state. boolean Discoverable [rw] Switch an adapter to discoverable or non-discoverable to either make it visible or hide it. If the DiscoverableTimeout is set to a non-zero value then the system will set this value back to false after the timer expired. In case the adapter is switched off, setting this value will fail. boolean Pairable [rw] Switch an adapter to pairable or non-pairable. Note that this property only affects incoming pairing requests. uint32 PaireableTimeout [rw] The pairable timeout in seconds. A value of zero means that the timeout is disabled and it will stay in pareable mode forever. uint32 DiscoverableTimeout [rw] The discoverable timeout in seconds. A value of zero means that the timeout is disabled and it will stay in discoverable/limited mode forever. The default value for the discoverable timeout should be 180 seconds (3 minutes). boolean Discovering [ro] Indicates that a device discovery procedure is active. list UUIDs [ro] List of 128-bit UUIDs that represents the available local services. AUTHOR
Alexander Orlenko <zxteam@gmail.com>. SEE ALSO
bt-agent(1) bt-audio(1) bt-device(1) bt-input(1) bt-monitor(1) bt-network(1) bt-serial(1) 2010-08-16 bt-adapter(1)
All times are GMT -4. The time now is 01:05 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.