Hello Experts,
I am using E250 on that solais 10 5/08 installed. I am unable to see disks. I connected 2 disks in that storage of 18gb each. When I run format command it is showing that 2 disks one is operating system and another one is 6MB. I checked probe-scsi and probe-scsi-all at ok prompt.
Its showing 8 units in that one unit is symbios remaining all are blank. Do i need RAID Manager 6.22.1 or do i need any firm ware upgradation? or do i need any kernel patches?
My firm ware version is 3.26.0 .
Thanks in advance
9 More Discussions You Might Find Interesting
1. UNIX for Dummies Questions & Answers
Hi,
I am a Dba and very new to filesystems and stuff.
I think that we have Veritas filesystems on my Sun SOlaris 5.8 box, how do I confirm this: all my filesystems are mounted like this:
/dev/vx/dsk...
Now we are also using disk arrays (storedge a1000) how do I access them from the system.... (1 Reply)
Discussion started by: knarayan
1 Replies
2. UNIX for Advanced & Expert Users
Hi,
I'm facing problem in connecting a Raid A1000 to E250 and E450. ( Both machines with Solaris 2.6 OS and patched, with different
scsi-initiator-ids - 7 & 3 ).
BTW, I'm not using this setup to access raid data from both machines simultaneously. There is Veritas Cluster Server monitoring... (1 Reply)
Discussion started by: shibz
1 Replies
3. UNIX for Dummies Questions & Answers
After searching and finding the link to the A1000 pdf ( http://192.18.99.138/805-7147/805-7147.pdf ) my questions are:
1) I have a battery failure on a A1000. I know that caching is disabled and it reports to see log. After reading the manual I have learned that the battery is a data-cache... (2 Replies)
Discussion started by: finster
2 Replies
4. UNIX for Advanced & Expert Users
Hello everyone. I'm trying to setup two A1000s connected to a single host w/ a dual port adapter. The host is a V480.
Do I need to have thesame firmware version on both controllers for the A1000s? If so, where can I download the latest and greatest firmware? I tried to google for it and... (8 Replies)
Discussion started by: xnightcrawl
8 Replies
5. Solaris
Sorry if this seems trivial. i have been given a task at work to configure a sun processing server "enterprise 4500" so it can work with the a storage server "storedge A5200" and "storedge D1000"
the truth is i have never worked on a sun server before. i need a guideline (step by step) as to... (5 Replies)
Discussion started by: lawalidowu
5 Replies
6. Filesystems, Disks and Memory
Hello,
i have a a1000 connected to an e6500. There's a raid 10 (12 disks) on the a1000.
If i do a
dd if=/dev/zero of=/mnt/1 bs=1024k count=1000
and then look at iostat it tells me there's a kw/s of 25000.
But if i do a
dd of=/dev/zero if=/mnt/1 bs=1024k count=1000
then i see only a... (1 Reply)
Discussion started by: mbrenner
1 Replies
7. Solaris
I'm currently planning to improve my skills on sun disk array and deciding whether to go with sun disk array A5200 or A1000. I have found a few good systems with decent price but still can't seem to find out which one to choose. For the host system, I have 1 ultra 5 and 1 e220r system. I will most... (5 Replies)
Discussion started by: agfa_109
5 Replies
8. Solaris
hi friends how we can create luns in A1OOO storage ..plzhelp its very urgent
when ever i am connect to A1000 raid controller through laptop with console cable with the help of hyperterminal..i isued serial port parameters which i mentioned below..
Set serial port parameters to:
�... (1 Reply)
Discussion started by: tv.praveenkumar
1 Replies
9. Solaris
I would want to ask on what software do i need to configure disk array for StorEdge A1000. (Sun Enterprise 450 - currently installed with SUN Solaris 9.)
Is it using RAID Manager 6.22? And is it compatible with SUN Solaris 9 or 10?
Thanks in advance for reading or replying my post. (2 Replies)
Discussion started by: beginningDBA
2 Replies
SCSI(4) Kernel Interfaces Manual SCSI(4)
Name
SCSI - Small Computer System Interconnect
Description
The ULTRIX system interfaces to disk and tape devices through the Small Computer System Interconnect (SCSI). Initial ULTRIX SCSI support
is limited to the Digital-supplied mass storage devices. The following devices are fully supported on the ULTRIX system:
o Winchester disks: RZ22, RZ23, RZ23L, RZ24, RZ55, RZ56, RZ57, RX23, RX26, RX33
o Magnetic tapes: TZ30, TZK50, TLZ04, TSZ05, TKZ08, TZK10
o Optical disks: RRD40, RRD42
Under the ULTRIX operating system, a SCSI device is referred to by its logical name. Logical names take the following form:
nn#
The nn argument is the two-character name; the number sign (#) represents the unit number. The two character names for SCSI devices are:
rz - RZ22, RZ23, RZ23L, RZ24, RZ55, RZ56, RZ57, RX23, RX26, RX33, RRD40, RRD42 disks
tz - TZ30, TZK50, TLZ04, TSZ05, TKZ08, and TZK10 tapes
The unit number is a combination of the SCSI bus number, either 0, 1, ... and the device's target ID number. The unit number is eight
times the bus number plus the target ID. For example, an RZ23 disk at target ID 3 on bus 0 would be referred to as rz3; a TZK50 tape at
target ID 5 on the second SCSI bus would be referred to as 13.
The SCSI bus has eight possible target device IDs. By default, one is allocated to the system. This allows for a maximum of seven target
devices connected to a SCSI bus.
Restrictions
The ULTRIX SCSI device driver does not operate with optical disks, other than the Digital-supplied devices.
The SCSI driver attempts to support on a best effort basis, non-Digital-supplied winchester disks and magnetic tapes.
The following notes apply to the driver's handling of non-Digital-supplied disks:
o These disks are assigned a device type of RZxx, instead of RZ22, RZ23, RZ23L, RZ55, RZ56, RZ57, RX23, RX26, or RX33. The RZxx disks
follow the same logical device naming scheme as the Digital-supplied disks.
o During the autoconfigure phase of the system startup, the driver prints the contents of the SCSI vendor ID, product ID, and the
revision level fields of the inquiry data return by the SCSI device.
o RZxx disks are assigned a default partition table. The default table can be modified by editing the sz_rzxx_sizes[8] entry in the
file The utility can also be used to modify the partition table on a RZxx disk.
o The only logical unit number (LUN) supported for each target ID is 0.
See Also
rz(4), tz(4), chpt(8)
SCSI(4)