10-27-2011
Thanks zxmaus, I guessed that might be the case.
9 More Discussions You Might Find Interesting
1. AIX
Problem description:
On the condition of EtherChannel function of AIX, when the data exchange between the nodes on the network, there sometimes lost datat packets and cause the application failed. Once we deconfig EtherChannel and use the single adapter configuration, the application works... (0 Replies)
Discussion started by: Frank2004
0 Replies
2. AIX
I'm trying to configure Etherchannel on AIX 5.3 and I'm having some problems. I am aggregating both of the onboard NIC's (ent0 and ent1) into a new adapter ent2 for failover reasons obviously. At first I was experiencing a problem where about 50% of all my packets would be dropped. Then after... (4 Replies)
Discussion started by: acascianelli
4 Replies
3. AIX
I have 1 AIX server, 4 dual ported fiber attached ethernet cards and 4 VLANS coming in. Is it possible to present those 8 ports as 1 IP address using etherchannel? Thanks. (5 Replies)
Discussion started by: jwholey
5 Replies
4. Shell Programming and Scripting
Combine points of specific key (a1) based on user defined size (lets say 200 in this example).
so a1 191 and 191+200 and sum of all the values (4th column)
and vice versa...
Thanx a bunch!
a1 191 201 1
a1 201 211 2
a1 211 221 1
a1
.......
....
a2.........
........ (7 Replies)
Discussion started by: quincyjones
7 Replies
5. AIX
I have one p5 server, no lpar, 2 physical network adapter, bundle as one EtherChannel. The two 2 physical network adapter connect to 2 network switches.
How to make this as a redundancy config?
Current is if one physical network adapter down, the seond one will go through the network. but if... (2 Replies)
Discussion started by: rainbow_bean
2 Replies
6. AIX
I have few AIX servers in my data center, which have their EtherChannel configured to have a fat pipe (active/active) and a nagios server to monitor the server uptimes. Nagios server pings every server in the data center and we have pretty much every known unix flavor in this data center. When... (3 Replies)
Discussion started by: thenomad
3 Replies
7. UNIX for Dummies Questions & Answers
I have 2 physical interfaces (bnx0 and bnx1) aggregated into aggr1. I need to assign second IP, and normally I know how to do it to physical interface (i.e. bnx0:1) however same trick (aggr1:1) is not working. Is there any way to do it? (0 Replies)
Discussion started by: bratan
0 Replies
8. Shell Programming and Scripting
Hi all,
I need to run a bunch of commands seperated by ; but then count the total lines of output. Pipes and redirection don't seem to be helping me. Anyone know how I can do this properly:
ls /usr/bin/nslookup ; ls /usr/sbin/lsof ; ls /sbin/ifconfig ; ls /usr/sbin/dmidecode ; ls... (2 Replies)
Discussion started by: dan-e
2 Replies
9. AIX
Hi Guys,
I am trying to test an etherchannel failover and switchback.
I did failover from primary to backup adapter, but now I am not able to switch it back to primary.
phcxxxxx:/ > entstat -d ent4 | grep Active
Active channel: backup adapter ... (1 Reply)
Discussion started by: snchaudhari2
1 Replies
KSE(4) BSD Kernel Interfaces Manual KSE(4)
NAME
kse -- Micrel 8842/8841 PCI Ethernet controller driver
SYNOPSIS
kse* at pci? dev ? function ?
DESCRIPTION
The kse driver supports Ethernet interfaces based on the Micrel 8842/8841 PCI Ethernet chips. The 8842 has 2 Ethernet ports which behave as
a managed switch to bridge each other. It works like a T-shape connector of Ethernet data flow in which an Ethernet controller sits at the
leg of the T. Frames can flow between the two ports while traffic destined for the 8842 reaches the EMAC. The 8841 is a plain 10/100 Ether-
net. The kse driver distinguishes and handles them according to the HW model.
SEE ALSO
arp(4), ifmedia(4), netintro(4), pci(4), ifconfig(8)
AUTHORS
The kse driver was written by Tohru Nishimura.
BUGS
__STRICT_ALIGNMENT case is not written. 8842 media selection keeps ``auto'' and indicates ``up 100baseTX-FX flow'' when either of two ports
is found link-up. There is no functional provision to see and control the media selection of them this moment. Advanced features like flow
volume bound, VLAN tag insertion/removal, QoS DiffServ are not implemented and remain uncontrollable by the kse driver. UDP4CSUM is not very
useful since the HW has an implementation error for the case when a large UDP datagram is fragmented into MTU sized frames.
BSD
July 6, 2006 BSD