opensolaris man page for metasync

Query: metasync

OS: opensolaris

Section: 1m

Format: Original Unix Latex Style Formatted with HTML and a Horizontal Scroll Bar

metasync(1M)						  System Administration Commands					      metasync(1M)

NAME
metasync - handle metadevice resync during reboot
SYNOPSIS
/usr/sbin/metasync -h /usr/sbin/metasync [-s setname] [buffer_size] metadevice /usr/sbin/metasync [-s setname] -r [buffer_size] /usr/sbin/metasync -p metadevice /usr/sbin/metasync -c metadevice
DESCRIPTION
The metasync command starts a resync operation on the specified metadevice. All components that need to be resynced are resynced. If the system crashes during a RAID5 initialization, or during a RAID5 resync, either an initialization or resync restarts when the system reboots. Applications are free to access a metadevice at the same time that it is being resynced by metasync. Also, metasync performs the copy oper- ations from inside the kernel, which makes the utility more efficient. Use the -r option in boot scripts to resync all possible submirrors.
OPTIONS
The following options are supported: -c metadevice Cancels the resync that is in progress on the specified metadevice. The resync will be stopped at its current point and can be resumed by running the "metasync metadevice" command. This option only applies to RAID1 volumes. -h Displays usage message. -p metadevice Regenerates parity information for RAID5 metadevices. -s setname Specifies the name of the diskset on which metasync will work. Using the -s option will cause the command to perform its administrative function within the specified diskset. Without this option, the command will perform its function on local metadevices. -r Specifies that the metasync command handle special resync requirements during a system reboot. metasync -r should only be invoked from the svc:/system/mdmonitor service. The metasync command only resyncs those metadevices that need to be resynced. metasync schedules all the mirror resyncs according to their pass numbers. To override the default buffer_size value used by the svc:/system/mdmonitor service, you can edit /etc/system to specify: set md_mirror:md_resync_bufsz = 2048 so that resyncs occur as quickly as possible.
OPERANDS
buffer_size Specifies the size (number of 512-byte disk blocks) of the internal copy buffer for the mirror resync. The size defaults to 1024 512-byte disk blocks. It can be no more than 2048 blocks. For best performance (quickest completion of the resync), 2048 blocks is the recommended size.
EXIT STATUS
The following exit values are returned: 0 Successful completion. >0 An error occurred.
ATTRIBUTES
See attributes(5) for descriptions of the following attributes: +-----------------------------+-----------------------------+ | ATTRIBUTE TYPE | ATTRIBUTE VALUE | +-----------------------------+-----------------------------+ |Availability |SUNWmdu | +-----------------------------+-----------------------------+
SEE ALSO
mdmonitord(1M), metaclear(1M), metadb(1M), metadetach(1M), metahs(1M), metainit(1M), metaoffline(1M), metaonline(1M), metaparam(1M), metarecover(1M), metarename(1M), metareplace(1M), metaroot(1M), metaset(1M), metassist(1M), metastat(1M), metattach(1M), md.tab(4), md.cf(4), mddb.cf(4), md.tab(4), attributes(5), md(7D)
NOTES
The metasync service is managed by the service management facility, smf(5), under the service identifier: svc:/system/mdmonitor Administrative actions on this service, such as enabling, disabling, or requesting restart, can be performed using svcadm(1M). The ser- vice's status can be queried using the svcs(1) command. SunOS 5.11 27 Mar 2006 metasync(1M)
Related Man Pages
metaoffline(1m) - opensolaris
metasync(1m) - sunos
metaoffline(1m) - sunos
metaparam(1m) - sunos
metaparam(1m) - linux
Similar Topics in the Unix Linux Community
How to modify the contents of file using script
Negate alerting for particular metadevice.
metadevice submirrors 0 and 1 not consistent
Need help to boot a server and mount all partitions
Can I reboot during a metadevice resync?