Sponsored Content
Operating Systems Solaris SVM metastat -- needs maintenance Post 97440 by Perderabo on Monday 30th of January 2006 01:11:23 PM
Old 01-30-2006
It's hard to know what to suggest because I don't understand how the box arrived in the current state. That syslog.conf thing scares me. I guess that I would first verify that I have good backups. Then I would look at the two disks with prtvtoc to ensure that they are partitioned identicly. Then I would look at the special files for the disks to make sure that no one replaced them text files or something. If the disks are partitioned correctly, no hardware error are known, and the special files really point to the device, then it has to be ok to attempt a resync. Or least, I think so. So I would cross my fingers and try:
metareplace -e d50 c1t0d0s5

No moneyback guarantees. Objects in mirror may be closer than they seem. Packed by weight, not by volume. Your results may vary. etc...
 

10 More Discussions You Might Find Interesting

1. Solaris

Help on metastat

hi all, can someone pls pass on your suggestion? Firs thing I am testing a script which checks for the pattern 'Needs Maintenance' from metastat output and prints some messages in the screen. So i need to simulate an error in mirrored disk for metastat to give this message 'Needs Maintenance'.... (3 Replies)
Discussion started by: srirammad007
3 Replies

2. Solaris

SVM - metastat - Last Erred

My company is running a solaris 2.7 machine. The machine is getting slow recently. I have no expert in solaris. Please help. I checked the log in /var/adm/message: I also checked with the command iostat -nE. It returns: Metastat returns the followings: What should i do now?... (10 Replies)
Discussion started by: nickychung
10 Replies

3. Filesystems, Disks and Memory

What should I do with this metastat result? metareplace everything?

I have to rescue the volumes in a soloris 7 machine. The metastat returns the following result: d6 is dying with iostat -nE returns Harderror 3, Transports error 9 Can some offer me some help? Thank you very much. (6 Replies)
Discussion started by: nickychung
6 Replies

4. Solaris

Softpartition State: Errored in Command MetaStat

Hi people, I have on problem when execute the command METASTAT... d60: Soft Partition Device: d10 State: Errored Size: 12582912 blocks (6.0 GB) Someone help me? Thank you very much (4 Replies)
Discussion started by: denisgomes
4 Replies

5. Solaris

Metastat shows "maintenance" and "last-erred"

Hi All, Sorry to post a problem for my first post but I'm in a bit of a pickle at the minute! I have an Ultra45 connected to a Storedge 3100 series, 2 internal, 2 external disks with a db application running on the external disks. Now everything is working fine and we've had no downtime or... (4 Replies)
Discussion started by: TheSteed
4 Replies

6. Solaris

SVM Solaris 8 Problem. Metastat output looping

Hi friends, I'm newbie to SVM. Just wanna try installed it on one of our server (to do mirroring for disk0 and disk1) but i think im lost until now. :( the steps i've taken is as below:- 1.prtvtoc /dev/rdsk/c1t0d0s2 | fmthard -s - /dev/rdsk/c1t1d0s2 2.metadb -a -c 3 -f c1t0d0s7... (3 Replies)
Discussion started by: kronenose
3 Replies

7. Solaris

restore metastat configuration after solaris upgrade

Greetings How can i restore metastat db after a solaris upgrade (9 to 10)? will it work if i save and restore /etc/vfstab and /etc/lvm/md.cf file? root@netad# metastat d35: Mirror Submirror 0: d38 State: Okay Submirror 1: d39 State: Okay Pass:... (2 Replies)
Discussion started by: kashif_islam
2 Replies

8. Shell Programming and Scripting

Grep contents from metastat command

Hi, after issuing metastat command I am getting output as follows Actually these soft partitions are more than 100. I want output as Device Name & Size. for eg d4004 2.0 GB (4 Replies)
Discussion started by: tuxian
4 Replies

9. Solaris

metastat |grep Needs

Dear, Required an script such that : If metastat |grep Needs , results in some output then this command to be executed for the same : opcmsg object=metastat a=OS msg_grp=OpC severity=critical msg_text="Need maintenance for the system $line" With regards, Mjoshi (3 Replies)
Discussion started by: mjoshi87
3 Replies

10. Solaris

Metastat shows state needs maintenance

Hi, We have a Solaris 10 machine with update 11 and was configured with IBM storage. It was assigned 2 LUNs (each 70GB) which were striped to make it 140GB. we have taken full backup of entire machine and Our storage team replaced IBM storage with Nimble storage (they did storage-level... (6 Replies)
Discussion started by: prvnrk
6 Replies
vgchgid(1M)															       vgchgid(1M)

NAME
vgchgid - modify the Volume Group ID (VGID) on a given set of physical devices SYNOPSIS
PhysicalVolumePath [PhysicalVolumePath] ... DESCRIPTION
The command is designed to change the LVM Volume Group ID (VGID) on a supplied set of disks. will work with any type of storage, but it is primarily targeted at disk arrays that are able to create "snapshots" or "clones" of mirrored LUNs. accepts a set of raw physical devices and ensures that they all belong to the same volume group, before altering the VGID (see section). The same VGID is set on all the disks and it should be noted that in cases of multi-PV volume groups, all the physical volumes should be supplied in a single invocation of the command. Options recognizes the following options and arguments: PhysicalVolumePath The raw devices path name of a physical volume. Background Some storage subsystems have a feature which allows a user to split off a set of mirror copies of physical storage (termed or just as LVM splits off logical volumes with the command. As the result of the "split," the split-off devices will have the same VGID as the original disks. is needed to modify the VGID on the BCV devices. Once the VGID has been altered, the BCV disks can be imported into a new volume group by using WARNINGS
Once the VGID has been changed, the original VGID is lost until a disk device is re-mirrored with the original devices. If is used on a subset of disk devices (for example, two out of four disk devices), the two groups of disk devices would not be able to be imported into the same volume group since they have different VGIDs on them. The solution is to re-mirror all four of the disk devices and re-run on all four BCV devices at the same time, and then use to import them into the same new volume group. If a disk is newly added to an existing volume group and no subsequent LVM operations has been performed to alter the structures (in other words, operations which perform an automated vgcfgbackup(1M)); then it is possible a subsequent will fail. It will report that the disk does not belong to the volume group. This may be overcome by performing a structure changing operation on the volume group (for example, using It is the system administrator's responsibility to make sure that the devices provided in the command line are all Business Copy volumes of the existing standard physical volumes and are in the ready state and writable. Mixing the standard and BC volumes in the same volume group can cause data corruption. RETURN VALUE
returns the following values: 0 VGID was modified with no error 1 VGID was not modified EXAMPLES
An example showing how might be used: 1. The system administrator uses the following commands to create the Business Continuity (BCV or BC) copy: 1) For EMC Symmetrix disks, the commands are and 2) For XP disk array, the commands are and Three BCV disks are created. 2. Change the VGID on the BCV disks. 3. Make a new volume group using the BCV disks. This step can be skipped as the group file will be created automatically. If the file is manually created it will have different major and minor numbers (see lvm(7)). 4. Import the BCV disks into the new volume group. 5. Activate the new volume group. 6. Backup the new volume group's LVM data structure. 7. Mount the associated logical volumes. SEE ALSO
vgimport(1M), vgscan(1M), vgcfgbackup(1M). vgchgid(1M)
All times are GMT -4. The time now is 03:37 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy