Sponsored Content
Operating Systems HP-UX is anybody using EMC symmetrix? Post 87967 by cooldugong on Saturday 29th of October 2005 09:21:30 PM
Old 10-29-2005
Many thanks

Thanks a lot.. I'll have a look those sites.
 

9 More Discussions You Might Find Interesting

1. UNIX for Advanced & Expert Users

Good sites to learn EMC symmetrix

i need to learn this very quick. i'm not trying delve deep into it. just enough to do basic things. does anyone know of any good sites to visit?? (1 Reply)
Discussion started by: TRUEST
1 Replies

2. Solaris

Emc

Dear gentelmen kindly please update me me how can i know disks on EMC and get size for all disks on EMC? (1 Reply)
Discussion started by: magasem
1 Replies

3. HP-UX

Emc

Dear gentelmen kindly please update me how can i know disks on EMC and get size for all disks on EMC? (0 Replies)
Discussion started by: magasem
0 Replies

4. HP-UX

Adding a new set of hardisk in EMC Symmetrix

Hello everyone! Could anybody help me how to configure a set of disk? From our existing EMC storage, we still have spaces for a new set of disk. I know how to replace a deffective disk but never had experience in setting/replacing a new pair of disk (M1 and M2). My objective here is to increase... (1 Reply)
Discussion started by: Tris
1 Replies

5. Solaris

EMC Failover

Hi guys, I'm running vxdmp and powerpath at the same time. Vxdmp for internal disks and powerpath for external. The problem is that, on the failover tests which a fiber cable should be removed, the system cannot recognize the disks. Any hints on how to configure powerpath in order to... (4 Replies)
Discussion started by: glenioborges
4 Replies

6. Red Hat

Configure EMC Powerpath?

Hi , I have a redhat 5.3 server which has 2 vg.. one is rootvg in local harddisk and another one is applicationvg in SAN.. When I reboot the server , EMC powerpath driver is not starting up automatically. Hence applicationvg is not mounting properly. Therefore I need to unmount it manually and... (4 Replies)
Discussion started by: Makri
4 Replies

7. AIX

Need EMC Symmetrix driver for AIX 5.3

Hi all, I hope I'm putting my first post at this site into the right forum. I need help finding the EMC disk driver for AIX version 5.3. I have some new EMC disk presented to a backup server of mine, and right now the EMC hdisks show up looking like this in an lsdev: hdisk495 Available... (2 Replies)
Discussion started by: C.J.Hund
2 Replies

8. AIX

Help with EMC BCV device

I'm trying to auto-mount EMC Symmetrix BCV device at boot. but having problem making BCV available. I put script called mkbcv to the inittab and engineer suggested to add 120 sec sleep between cfgmgr so I did that also. My mkbcv script seems to be working fine, it says "hdisk4 Available" ... (1 Reply)
Discussion started by: shuhei365
1 Replies

9. AIX

AIX Sanboot from EMC Symmetrix with NPIV

Hi All.. On to a new implementation with AIX 7.1 san boot from EMC disks (Using NPIV). Anyone played with this recently? Wondering if we need PowerPath on the AIX clients or has native MPIO matured to replace it. Thoughts? Thanks Mr B (6 Replies)
Discussion started by: balaji_prk
6 Replies
vgchgid(1M)															       vgchgid(1M)

NAME
vgchgid - modify the Volume Group ID (VGID) on a given set of physical devices SYNOPSIS
PhysicalVolumePath [PhysicalVolumePath] ... DESCRIPTION
The command is designed to change the LVM Volume Group ID (VGID) on a supplied set of disks. will work with any type of storage, but it is primarily targeted at disk arrays that are able to create "snapshots" or "clones" of mirrored LUNs. accepts a set of raw physical devices and ensures that they all belong to the same volume group, before altering the VGID (see section). The same VGID is set on all the disks and it should be noted that in cases of multi-PV volume groups, all the physical volumes should be supplied in a single invocation of the command. Options recognizes the following options and arguments: PhysicalVolumePath The raw devices path name of a physical volume. Background Some storage subsystems have a feature which allows a user to split off a set of mirror copies of physical storage (termed or just as LVM splits off logical volumes with the command. As the result of the "split," the split-off devices will have the same VGID as the original disks. is needed to modify the VGID on the BCV devices. Once the VGID has been altered, the BCV disks can be imported into a new volume group by using WARNINGS
Once the VGID has been changed, the original VGID is lost until a disk device is re-mirrored with the original devices. If is used on a subset of disk devices (for example, two out of four disk devices), the two groups of disk devices would not be able to be imported into the same volume group since they have different VGIDs on them. The solution is to re-mirror all four of the disk devices and re-run on all four BCV devices at the same time, and then use to import them into the same new volume group. If a disk is newly added to an existing volume group and no subsequent LVM operations has been performed to alter the structures (in other words, operations which perform an automated vgcfgbackup(1M)); then it is possible a subsequent will fail. It will report that the disk does not belong to the volume group. This may be overcome by performing a structure changing operation on the volume group (for example, using It is the system administrator's responsibility to make sure that the devices provided in the command line are all Business Copy volumes of the existing standard physical volumes and are in the ready state and writable. Mixing the standard and BC volumes in the same volume group can cause data corruption. RETURN VALUE
returns the following values: 0 VGID was modified with no error 1 VGID was not modified EXAMPLES
An example showing how might be used: 1. The system administrator uses the following commands to create the Business Continuity (BCV or BC) copy: 1) For EMC Symmetrix disks, the commands are and 2) For XP disk array, the commands are and Three BCV disks are created. 2. Change the VGID on the BCV disks. 3. Make a new volume group using the BCV disks. This step can be skipped as the group file will be created automatically. If the file is manually created it will have different major and minor numbers (see lvm(7)). 4. Import the BCV disks into the new volume group. 5. Activate the new volume group. 6. Backup the new volume group's LVM data structure. 7. Mount the associated logical volumes. SEE ALSO
vgimport(1M), vgscan(1M), vgcfgbackup(1M). vgchgid(1M)
All times are GMT -4. The time now is 07:40 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy