Sponsored Content
Special Forums Hardware Filesystems, Disks and Memory 2-Ch RAID Problem in SCO Open Server Post 32412 by ncmurf00 on Monday 25th of November 2002 12:03:52 PM
Old 11-25-2002
Depends on the storage array you're running.
I have a MOD30 with 2 controllers, but they control the same drives. Within the operating system, you should probably setup a vg, or something like a mirror. What this does is when a controller goes down, the system will pull from the second controller automatically, thus the same drives, but a different address.

Hope this is helpful
 

10 More Discussions You Might Find Interesting

1. UNIX for Dummies Questions & Answers

sco open server 5.0.6

I'm new to the whole Unix thing and have inherited a network running Macs, Windows 2000 and Unix. The Unix side is very suspect at this point and I want to change out the server. I'd love to use one of the new Apple servers but can't find any info on what "flavors" of Unix it will run. Specificly... (3 Replies)
Discussion started by: matthewd
3 Replies

2. UNIX for Advanced & Expert Users

SCO Open Server 5.05 Installaltuion

I'm in the process of installing SCO Open Server 5.05 on the following platform: Hardware: IBM 300PL 64 MB RAM Yamaha 16/4/16 CDRW (Internal defined on SCSI ID 3 LUN 0) I'm able to boot from the CD and advance to the Installation screen but when it asks for where the media source will... (3 Replies)
Discussion started by: budrito
3 Replies

3. SCO

SCO Open Server.

Dear All, I am considering installing SCO Open Server as an alternative to MS Exchange. Has anybody had any real world experience of using Open Office? Thanks, TC. (1 Reply)
Discussion started by: TCuk
1 Replies

4. Shell Programming and Scripting

IInd Hard Disk Mounting Problem on 1st HDD On SCO UNIX Open Server

Hi Engg. ! :mad: I have a harddisk on which SCO UNIX Open Server was installed. There was some data (in .dbf format) on it. Present condition of HDD is that it is not booting. Now I want to mount this HDD through other HDD on which SCO UNIX Open Server is installed by attaching... (0 Replies)
Discussion started by: Niraj Gopal Sha
0 Replies

5. SCO

Sco Open Server 5.05

How can I to know procesor type. (1 Reply)
Discussion started by: Batya
1 Replies

6. Filesystems, Disks and Memory

Unix Sco Open Server, Windows Computers Problem Access Unix Shared Files Help!!!!!

Hello Moto I hope someone can help We's here at work, have a unix box with sco openserver 5 on it, so it has a nice gui interface.. and also a fair few windows computers.. a system admin guy b4 me, has set up a user called neil, which can, when u try to access the unix box using windows... (2 Replies)
Discussion started by: haggo
2 Replies

7. SCO

How to activate/use networkcards SCO Open Server

Hi, in our business we have a formerly (few years ago) installed computer with an openserver SCO 5.05 there are 3 network cards in it. one on board and two 3Com-cards Looking with ifconfig (or scoadmin) they seemed to be installed correctly. IP-Adress, netmask broadcas looks OK. But no... (3 Replies)
Discussion started by: klex
3 Replies

8. SCO

Purchase of SCO Open Server 6.0

I have to purchase SCO Open Server 6.0, so I want to know from where I can get SCO Open Server 6.0 and what is the min. cost in which I can avail this. Thanks and Regards Himanshu Software Engineer R&D Department (4 Replies)
Discussion started by: ghimanshu
4 Replies

9. SCO

raid 1 configuration in sco open unix

Dear Team , how i can configure raid 1 (mirroring) using ide hdd in sco open unix 5 i have two 80gb identical hdd (same make/model) thanx (0 Replies)
Discussion started by: sudhir69
0 Replies

10. SCO

SCO Open Server

Hi, Completely new to UNIX - so be gentle Cut a long story short, we have a micros 8700 system (eclipse) that needs the Micros 8700 software installed. The system needs UNIX and I have downloaded and successfully installed SCO open Server 6 and can log into root e.t.c. Now I have... (13 Replies)
Discussion started by: kennyruss
13 Replies
format(1M)																format(1M)

NAME
format - format an HP SCSI disk array LUN SYNOPSIS
device_file DESCRIPTION
formats one LUN of the HP SCSI disk array associated with device file, device_file. The format will usually be a soft or zeroing format, in which the controller writes zeroes to the data area and parity area, if any, of the LUN. NOTE: The above should always be true of a sub-LUN, but the controller might decide, based on certain conditions, to do a full format of a regular LUN, which consists of sending a mode select and a media initialization command to the physical drive(s) in question, fol- lowed by zeroing the data and parity area, if any. The conditions which will cause a full format to be done are as follows: 1. The controller received a Mode Select command which requires a drive sector size change. 2. The controller received a Mode Select command which changed a parameter in the Format Device Page(0x03). 3. The LUN contains one or more failed drives. In this case only a certain subset of the drives containing the failed drives will be formatted. 4. Either the FmtData or the CmpLst bit in the Format Unit CDB is set. RETURN VALUE
returns the following values: 0 Successful completion. -1 Command failed. DIAGNOSTICS AND ERRORS
Errors can originate from problems with: o o SCSI (device level) communications o system calls Error messages generated by format: An error in command syntax has occurred. Enter command again with all required arguments, in the order shown. To ensure that does not modify a disk array that is being used by another process, attempts to obtain exclusive access to the disk array. If the disk array is already opened by another process (for example, LVM -- the Logical Volume Manager), a "" error message is returned by the driver. To eliminate the "" condition, determine what process has the device open. In the case of LVM, it is necessary to deactivate the volume group containing the array before formatting array LUNs (see vgchange(1M)). The LUN number, which is derived from the device file name, is out of range. The addressed LUN is not configured, and thus is not known to the array controller. Utilities must be able to open the device file for raw access. The device being addressed is not an HP SCSI disk array. SCSI (device level) communication errors: Sense data associated with the failed operation is printed. Error messages generated by system calls: uses the following system calls: and Documentation for these HP-UX system calls contains information about the specific error conditions associated with each call. does not alter the value of The interpretation of for printing purposes is performed by the system utility EXAMPLES
To format the HP SCSI disk array LUN on a Series 800: WARNING
The command will destroy all user data on the addressed LUN. DEPENDENCIES
The HP C2425 and HP C2427 disk arrays are only supported on Series 700 systems running HP-UX version 9.0X. The HP C2430 disk array is supported on Series 700 and 800 systems running HP-UX versions 9.0X and 10.0X. AUTHOR
was developed by HP. format(1M)
All times are GMT -4. The time now is 10:13 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy