On 4/20/2018, we performed a disk replacement on our IBM 8202 P7 server. After the disk was rebuilt, the SAS Disk Array sissas0 showed a status of degraded. However, the pdisks in the array all show a status of active.
We did see a message in errpt. DISK ARRAY PROTECTION SUSPENDED.
I've attempted to find out what the DISK ARRAY PROTECTION SUSPENDED message means, but no success.
Any ideas?
Thanks
Terry Andrews
system administrator.
10 More Discussions You Might Find Interesting
1. UNIX for Dummies Questions & Answers
I have just started getting into unix and aquired a Sun Ultra 5 however the disk failed and I want to replace it with a spare maxtor 40Gb i have lying around. I need to partition and format the disk from its old windows format. I have looked up info on the format command in solaris 9 and I think i... (2 Replies)
Discussion started by: kalm
2 Replies
2. Solaris
I dont even know what raid level this is, but its raid 5 mirrored from the looks of it.
I have a failed disk (t12) within this mirror. What is the best way to replace this disk? 2 things concern me, isn't there a command to prepare the disk for a hot swap? and what should i do with the... (3 Replies)
Discussion started by: BG_JrAdmin
3 Replies
3. Red Hat
Hi all,
I need some help with a RHEL 4 on a Sun Fire v65x machine.
Some of the disks is damaged or has a hardware issue. This disk is connected to a hardware raid.
The problem is that I don't know what is the brand, model and capacity of the disk.
I've read the raid manual, but says... (3 Replies)
Discussion started by: adelgadom
3 Replies
4. Solaris
Hello,
Can someone advise the proper procedure for replacing a mirrored disk in SVM. I have checked the docs and various websites but the procedure seems to vary. This is what I would do...
1. Remove the db replicas from the bad disk.
2. Detach it from the mirror
3. Clear it with... (4 Replies)
Discussion started by: Actuator
4 Replies
5. HP-UX
hi all!
I found a the state of disk at JA0/D13 was failed this morning.
then i replaced it this afternoon,but i run
#dsp -s
the array status displayed
====================================
STATUS
Subsystem State: 1
The Subsystem is TESTING.
The array is REBUILDING and is 87%... (0 Replies)
Discussion started by: JoyOnLine
0 Replies
6. AIX
Hi,
The system is a Power6 8204 with an external storage 7031. OS is AIX 5.3. I replaced a failed disk hdisk28 and put it back to the volume group. Everything looks just fine. After the replacement, errpt has kept sending "Perm DISK OPERATION ERROR".
Other than the error, everything still... (1 Reply)
Discussion started by: aixlover
1 Replies
7. Solaris
Hello,
I have a Sparc system with encapsulated disks.
Because of disk errors I had to replace rootdisk,
I did it with
vxdiskadm 4)
replacement, vxdctl disable/enable,
vxdiskadm 5)
After it it the system boot failed, dropped back to the ok> prompt, message was:
The file... (0 Replies)
Discussion started by: ggi
0 Replies
8. HP-UX
Hello,
I'm new to this forum and as you will see from my question I'm new to UNIX as well.
One of our costumers has HP rx4640 running on UNIX with two 300GB hot-swappable disks that are mirrored. They reported to us that one of the disks is faulty and they want us to take care of it. Below is... (16 Replies)
Discussion started by: gjk
16 Replies
9. AIX
Hi,
One of my disk is in 'disk missing state'. It is a sharedVG and cluster nodes.
The errpt keeps reporting stale partition error.
lvs are in open/stale state.
In this sceanario is replacing the disk the best practice?
When i do a lsdev the disk is labelled as below.
hdisk3 Available ... (2 Replies)
Discussion started by: ElizabethPJ
2 Replies
10. AIX
Hello,
On 4/20/2018, we performed a disk replacement on our IBM 8202 P7 server. After the disk was rebuilt, the SAS Disk Array sissas0 showed a status of degraded. However, the pdisks in the array all show a status of active.
We did see a message in errpt. DISK ARRAY PROTECTION SUSPENDED.
... (3 Replies)
Discussion started by: terrya
3 Replies
CISS(4) BSD Kernel Interfaces Manual CISS(4)
NAME
ciss -- HP/Compaq Smart ARRAY 5/6 RAID controllers
SYNOPSIS
ciss* at pci? function ?
DESCRIPTION
The ciss driver provides support for the CISS interface implemented by fifth and later generations of the HP/Compaq Smart ARRAY family of
controllers.
The CISS interface is defined in the document entitled CISS Command Interface for SCSI-3 Support Open Specification, Version 1.04, Valence
Number 1, Compaq Computer Corporation, 2000/11/27.
This driver supports several Compaq and HP controllers implementing the CISS interface, including:
o Compaq Smart Array 5300 version 1
o Compaq Smart Array 5300 version 2
o Compaq Smart Array 5i version 1
o Compaq Smart Array 5i version 2
o HP Smart Array 5312
o HP Smart Array 6i
o HP Smart Array 641
o HP Smart Array 642
o HP Smart Array 6400
o HP Smart Array 6400 EM
o HP Smart Array E200
o HP Smart Array E200i
o HP Smart Array P400
o HP Smart Array P400i
o HP Smart Array P600
o HP Smart Array P800
o HP Smart Array V100
o HP Smart Array 1 through 13
These controllers support RAID 0, RAID 1, RAID 5, JBOD, and superpositions of those configurations.
Although the controllers are actual RAID controllers, the ciss driver makes them look just like SCSI controllers. All RAID configuration
must be done through the controllers' BIOSes.
Hardware from previous generations of this product family may be supported by the cac(4) driver.
SEE ALSO
bio(4), cac(4), intro(4), pci(4), scsi(4), sd(4)
HISTORY
The ciss driver first appeared in NetBSD 3.1.
AUTHORS
The ciss driver was written by Michael Shalayeff <mickey@openbsd.org>, and ported to NetBSD by Tonnerre Lombard <tonnerre@netbsd.org>.
BSD
May 28, 2008 BSD