Sponsored Content
Operating Systems Solaris Fsck: alignment error Solaris 8, SUN Netra AX11505 Post 302861843 by fpmurphy on Wednesday 9th of October 2013 04:58:24 PM
Old 10-09-2013
Maybe the IDE disk has come to EOL. Whhen was the last time you rebooted the system?
 

9 More Discussions You Might Find Interesting

1. Solaris

Memory Alignment Problem on Sun Sparcs

Hi, I try to marshal a unsigned int and a char * into a buffer, and then unmarshal them later to get them out. I need to put the char * in the front and unsigned int at the end of the buffer. However, my system always give me "BUS ERROR". I am using Sun Sparcs Sloris 2.10. My code to marshal the... (1 Reply)
Discussion started by: nj302
1 Replies

2. Solaris

Sun Fire V1280 / E2900 / Netra 1280

Hello, I'm trying to fix this server System Board (CPU/Memory Unit). The error indicates that its missing 3.3VDC. So far all the fuses and caps have been checked. I new at this type of machine, need help for idea on this system. Thank you in advance. Vu (0 Replies)
Discussion started by: vhtran
0 Replies

3. Solaris

sun netra t1

so i've grabbed this sun netra t1 for some small dev work. now obviously i need to install sol10. no problem done it a million times except for the fact that i've never actually done it w/o a term server. so i grab a usb to serial and a serial to rj45 (the one you get in every cisco order.. roll... (24 Replies)
Discussion started by: pupp
24 Replies

4. Solaris

Netra V440 & Netra 1290 keyswitch

Hello, I wrote a script which monitor the keyswitch state repeatedly each 10 minutes. I'm extracting the keyswitch status by using prtdiag. The script works fine for Netra v440 , but I found that prtdiag under Netra 1290 don't give keyswitch status. unlike Netra 440 server , I found that... (2 Replies)
Discussion started by: Alalush
2 Replies

5. Solaris

Sun Netra T1 won't poweron/no POST

Hi guys. I have an old Netra T1 that I'm hoping to recover here so I can twiddle around with Solaris 10. It's been unable to power on despite issuing the "poweron" command or hitting the switch at the back of the server for some time. The LOM command "env" reports ALARM3 ON and everything else... (8 Replies)
Discussion started by: detach8
8 Replies

6. Solaris

SUN Netra 240 Boot error

Hi, When I am trying to boot my SUN Netra 240 Machine its giving some boot error. > {1} ok boot -i > Boot device: /pci@1c,600000/scsi@2/disk@0,0:a File and args: -i > Boot load failed. > The file just loaded does not appear to be executable. > {1} ok I tried to boot it from cdrom... (9 Replies)
Discussion started by: ppandey21
9 Replies

7. Hardware

[solved] Sun Netra X1 - Adding a Second Hard Drive

As the title suggests, I'm trying to install a second drive (really want an OS mirror) on a Sun Netra X1. I've taken the spacer out, and had a go at with the drill-press so now I have a nice HDD tray. Have installed an IDE drive in the tray, plugged in the power and data cables that were... (0 Replies)
Discussion started by: Smiling Dragon
0 Replies

8. Hardware

Sun Oracle Netra T5220 processor help

I recently required some Sun Oracle Netra T5220s. I do not have much knowledge of Sun products. The units do not have video cards or hard drives. How can I tell/go about figuring out what clock speed and how many cores the processor is? They are all outfitted with 32GB of memory. Two are... (11 Replies)
Discussion started by: nerdboy
11 Replies

9. Solaris

SUn Netra X4200 M2 Drivers

Hi Guys, Could someone please share the dvd/cd that came with server Netra x4200 M2 since it is not more available in Oracle site? Or do you know where I can get that? Thanks! (4 Replies)
Discussion started by: CristianS
4 Replies
HD(4)							     Linux Programmer's Manual							     HD(4)

NAME
hd - MFM/IDE hard disk devices DESCRIPTION
The hd* devices are block devices to access MFM/IDE hard disk drives in raw mode. The master drive on the primary IDE controller (major device number 3) is hda; the slave drive is hdb. The master drive of the second controller (major device number 22) is hdc and the slave hdd. General IDE block device names have the form hdX, or hdXP, where X is a letter denoting the physical drive, and P is a number denoting the partition on that physical drive. The first form, hdX, is used to address the whole drive. Partition numbers are assigned in the order the partitions are discovered, and only nonempty, nonextended partitions get a number. However, partition numbers 1-4 are given to the four partitions described in the MBR (the "primary" partitions), regardless of whether they are unused or extended. Thus, the first logi- cal partition will be hdX5. Both DOS-type partitioning and BSD-disklabel partitioning are supported. You can have at most 63 partitions on an IDE disk. For example, /dev/hda refers to all of the first IDE drive in the system; and /dev/hdb3 refers to the third DOS "primary" partition on the second one. They are typically created by: mknod -m 660 /dev/hda b 3 0 mknod -m 660 /dev/hda1 b 3 1 mknod -m 660 /dev/hda2 b 3 2 ... mknod -m 660 /dev/hda8 b 3 8 mknod -m 660 /dev/hdb b 3 64 mknod -m 660 /dev/hdb1 b 3 65 mknod -m 660 /dev/hdb2 b 3 66 ... mknod -m 660 /dev/hdb8 b 3 72 chown root:disk /dev/hd* FILES
/dev/hd* SEE ALSO
chown(1), mknod(1), sd(4), mount(8) COLOPHON
This page is part of release 3.25 of the Linux man-pages project. A description of the project, and information about reporting bugs, can be found at http://www.kernel.org/doc/man-pages/. Linux 1992-12-17 HD(4)
All times are GMT -4. The time now is 04:48 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy