Hi,

of course importvg will recognize the data on the hdiskpower devices, the two 'hdisks' on emc are only paths to the same physical disk.

We did this kind of migrations in both directions - from powerpath to vio and the other way round - and haven't seen any issues so far.

Regards
zxmaus
This User Gave Thanks to zxmaus For This Post:
 

10 More Discussions You Might Find Interesting

1. Solaris

change SP value in powerpath

How to change the following values in power path from SP B to SP A ? Owner: default=SP B, current=SP B this is excerpt from powermt display dev=all (3 Replies)
Discussion started by: fugitive
3 Replies

2. AIX

Anyone using NPIV?

Is anyone here using NPIV with AIX? If you are, what type of switch are you connected to? Also, please share some impressions of NPIV over traditional port-to-port LUN assignments. We are looking to move to NPIV and need some convincing argume... I mean information. (2 Replies)
Discussion started by: kah00na
2 Replies

3. AIX

Vscsi and npiv on same adapter

Hi, I want to change from vscsi to npiv. Is it possible to use both on the same adapter, so we can change the systems one by one, or must we place a second FC adapter in the VIO servers? Thanks, Ronald (2 Replies)
Discussion started by: ronaldm60
2 Replies

4. AIX

hdisk mapping to a vSCSi Adapter

Hello, I have a VIOS System and would like to do mapping some hdisks, hdisk160 until hdisk165 to a vSCSi Adapter. I try to do this in the oem_setup_env like the following: for i in $(lspv | grep hdisk* | awk {'print $1'}; do mkdev -V $i -p vhost20 done There where a mapping with... (4 Replies)
Discussion started by: torsten163
4 Replies

5. AIX

NPIV mapping problem

Hello all I hope someone can help me with this. I have a single LPAR which is supplied a rootvg and datavg disk set from a dual VIO server configuration. I see dual path disks for all the datavg disks but only see one path for the rootvg disks. The client LPAR has the following: fcs0 ... (3 Replies)
Discussion started by: johnf
3 Replies

6. AIX

NPIV custom WWN

Hi All :) i would like to know if i can customize the WWN of the new VFC (NPIV). Or, if i must move the LPAR on another server with another FCS, i have to change the zoning?? Thanks in advance. Mario ---------- Post updated 09-21-12 at 02:51 AM ---------- Previous update was 09-20-12 at... (1 Reply)
Discussion started by: Zio Bill
1 Replies

7. AIX

VIOS FC Mapping/NPIV questions

Please forgive me here as I don't fully understand what I am talking about here so if I use the wrong terminology please overlook me. We have multiple AIX LPARs on the managed system with two VIO Servers. A Co-Worker and I are trying to set up a new LPAR client (The guy that knows this is out)... (14 Replies)
Discussion started by: juredd1
14 Replies

8. AIX

Kdb - vscsi disk mapping from AIX 5.3 CLIENT side

If you're familiar with vscsi mappings thru a VIO Server, you are probably aware, on an AIX 6.1 Client LPAR, that: print cvai | kdbcan provide useful information to you.... like VIO Server name & vhost #. But, "cvai" does not appear to be part of the Kernel Debugger in AIX 5.3. My question is... (3 Replies)
Discussion started by: The Doctor
3 Replies

9. AIX

How to put vscsi in available state?

Hello Friends, My question/problem is that I noticed 2 servers in my environment vscsi is showing up as defined (not available) or is defined and not showing the path to both vscsi's when ruining lspath command. I am new to AIX admin, work alone, and work in an small environment. My question is,... (12 Replies)
Discussion started by: Adnans2k
12 Replies

10. AIX

Devices.vscsi.disk ?

Hello, When I assigned CDROM from IVM (VIOS) to LPAR and then running cfgmgr i get the following message on the client lpar #cfgmgr cfgmgr: 0514-621 WARNING: The following device packages are required for device support but are not currently installed. devices.vscsi.disk searching... (0 Replies)
Discussion started by: filosophizer
0 Replies
vgchgid(1M)															       vgchgid(1M)

NAME
vgchgid - modify the Volume Group ID (VGID) on a given set of physical devices SYNOPSIS
PhysicalVolumePath [PhysicalVolumePath] ... DESCRIPTION
The command is designed to change the LVM Volume Group ID (VGID) on a supplied set of disks. will work with any type of storage, but it is primarily targeted at disk arrays that are able to create "snapshots" or "clones" of mirrored LUNs. accepts a set of raw physical devices and ensures that they all belong to the same volume group, before altering the VGID (see section). The same VGID is set on all the disks and it should be noted that in cases of multi-PV volume groups, all the physical volumes should be supplied in a single invocation of the command. Options recognizes the following options and arguments: PhysicalVolumePath The raw devices path name of a physical volume. Background Some storage subsystems have a feature which allows a user to split off a set of mirror copies of physical storage (termed or just as LVM splits off logical volumes with the command. As the result of the "split," the split-off devices will have the same VGID as the original disks. is needed to modify the VGID on the BCV devices. Once the VGID has been altered, the BCV disks can be imported into a new volume group by using WARNINGS
Once the VGID has been changed, the original VGID is lost until a disk device is re-mirrored with the original devices. If is used on a subset of disk devices (for example, two out of four disk devices), the two groups of disk devices would not be able to be imported into the same volume group since they have different VGIDs on them. The solution is to re-mirror all four of the disk devices and re-run on all four BCV devices at the same time, and then use to import them into the same new volume group. If a disk is newly added to an existing volume group and no subsequent LVM operations has been performed to alter the structures (in other words, operations which perform an automated vgcfgbackup(1M)); then it is possible a subsequent will fail. It will report that the disk does not belong to the volume group. This may be overcome by performing a structure changing operation on the volume group (for example, using It is the system administrator's responsibility to make sure that the devices provided in the command line are all Business Copy volumes of the existing standard physical volumes and are in the ready state and writable. Mixing the standard and BC volumes in the same volume group can cause data corruption. RETURN VALUE
returns the following values: 0 VGID was modified with no error 1 VGID was not modified EXAMPLES
An example showing how might be used: 1. The system administrator uses the following commands to create the Business Continuity (BCV or BC) copy: 1) For EMC Symmetrix disks, the commands are and 2) For XP disk array, the commands are and Three BCV disks are created. 2. Change the VGID on the BCV disks. 3. Make a new volume group using the BCV disks. This step can be skipped as the group file will be created automatically. If the file is manually created it will have different major and minor numbers (see lvm(7)). 4. Import the BCV disks into the new volume group. 5. Activate the new volume group. 6. Backup the new volume group's LVM data structure. 7. Mount the associated logical volumes. SEE ALSO
vgimport(1M), vgscan(1M), vgcfgbackup(1M). vgchgid(1M)
All times are GMT -4. The time now is 06:58 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy