Sponsored Content
Full Discussion: Anyone using NPIV?
Operating Systems AIX Anyone using NPIV? Post 302492078 by AixCraft on Saturday 29th of January 2011 03:18:18 PM
Old 01-29-2011
Yes

Hi, Im using NPIV on three places,
But I dont remember the switch we are using there, I'll check it for you.
In general the latest switch (since from 2010 maybe eralier) support using NPIV technology.
 

8 More Discussions You Might Find Interesting

1. AIX

Migrating hdisks from vscsi to NPIV with powerpath

Hi All, I'm preparing to migrate some servers from vscsi to pass-thru NPIV. I am planning to have the SAN team move the exact LUNs from vio1/vio2 to those two VWWN through NPIV. My question is on the partition itself.. right now, let's say I have hdisk0/1/2/3/4 that are part of datavg. They... (2 Replies)
Discussion started by: lapfrank
2 Replies

2. AIX

NPIV with 8Gb PCI Express Dual Port FC Adapter

All I am at a loss with a VIO server running ios 2.2.0.10-FP-24 SP-01. The VIO server is fitted with two 8Gb PCI Express Dual Port FC Adapters. However when I run the lsnports command only two of the adapter ports show as capable: $ lsnports name physloc ... (4 Replies)
Discussion started by: johnf
4 Replies

3. AIX

AIX Sanboot from EMC Symmetrix with NPIV

Hi All.. On to a new implementation with AIX 7.1 san boot from EMC disks (Using NPIV). Anyone played with this recently? Wondering if we need PowerPath on the AIX clients or has native MPIO matured to replace it. Thoughts? Thanks Mr B (6 Replies)
Discussion started by: balaji_prk
6 Replies

4. AIX

Vscsi and npiv on same adapter

Hi, I want to change from vscsi to npiv. Is it possible to use both on the same adapter, so we can change the systems one by one, or must we place a second FC adapter in the VIO servers? Thanks, Ronald (2 Replies)
Discussion started by: ronaldm60
2 Replies

5. AIX

NPIV mapping problem

Hello all I hope someone can help me with this. I have a single LPAR which is supplied a rootvg and datavg disk set from a dual VIO server configuration. I see dual path disks for all the datavg disks but only see one path for the rootvg disks. The client LPAR has the following: fcs0 ... (3 Replies)
Discussion started by: johnf
3 Replies

6. AIX

NPIV custom WWN

Hi All :) i would like to know if i can customize the WWN of the new VFC (NPIV). Or, if i must move the LPAR on another server with another FCS, i have to change the zoning?? Thanks in advance. Mario ---------- Post updated 09-21-12 at 02:51 AM ---------- Previous update was 09-20-12 at... (1 Reply)
Discussion started by: Zio Bill
1 Replies

7. AIX

VIOS FC Mapping/NPIV questions

Please forgive me here as I don't fully understand what I am talking about here so if I use the wrong terminology please overlook me. We have multiple AIX LPARs on the managed system with two VIO Servers. A Co-Worker and I are trying to set up a new LPAR client (The guy that knows this is out)... (14 Replies)
Discussion started by: juredd1
14 Replies

8. AIX

AIX san boot from EMC2 & NPIV

Hi all , we're implementing a new NPIV infrastructure with AIX san boot on EMC2 VMAX 5876 , for economic reason , they don't wont to install Powerpath multipath sw , but only ODM drivers from EMC2 , this behavior is supported and can work?! in the past we implemented NPIV on DS8000 family... (2 Replies)
Discussion started by: BabylonRocker76
2 Replies
devswmgr(8)						      System Manager's Manual						       devswmgr(8)

NAME
devswmgr - utility to manage the device switch database SYNOPSIS
/sbin/devswmgr [-option [parameter]] OPTIONS
Displays the following information about the device switch database: Whether a device switch database was read from the primary file or from a backup file The number of entries that are in the device switch table Displays the major numbers that have been reserved by all drivers, a named driver, or an instance of a named driver. A driver that requires more than one entry in the device switch table uses a unique instance number to reference each of its device switch table entries. Displays help for the devswmgr command. Releases all the major numbers for a device driver if just the driver name is specified. Releases one major number for a device driver if the NAME and the INSTANCENUM of the driver are speci- fied. DESCRIPTION
The devswmgr command helps you manage the device switch table by displaying information about the devices drivers in the table. You can also use the command to release device switch table entries. Typically, you release the entries for a driver after you have unloaded the driver and do not plan to reload it later. Releasing the entries frees them for use by other device drivers. EXAMPLES
The following example shows that a device switch table was loaded from the primary device and that there are 70 entries in it: % /sbin/devswmgr -display Device switch information device switch database read from primary file device switch table has 70 entries The following example shows the major numbers in the device switch table that have been reserved for the driver named cam_disk: % /sbin/devswmgr -getnum driver=cam_disk Device switch reservation list (*=entry in use) driver name instance major ------------------------------- -------- ----- cam_disk 1 8* FILES
The file that manages the device switch databases The primary device switch database file The backup device switch database file SEE ALSO
Commands: scsimgr(8) devswmgr(8)
All times are GMT -4. The time now is 06:17 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy