Sponsored Content
Operating Systems AIX add SSA pdisk to array to become hdisk Post 302483868 by purdym on Tuesday 28th of December 2010 05:36:59 PM
Old 12-28-2010
So the disk has shown up as a pdisk but NOT an hdisk?

You need to go into smit and the change the disk from an 'array disk' to a 'system disk'. I forget the exact menus now. Start with: smitty ssaraid, I think.
 

10 More Discussions You Might Find Interesting

1. AIX

RS6000 SSA Raid question

Hi Can I add disks on the fly to extend the capacity of an existing RAID 5 volume? It's created on a 4P Advanced SSA Raid Adapter. I need to extend a volume group, so I figured it would be easiest to extend the "physical disk" which is a RAID5 volume. Thanks. (1 Reply)
Discussion started by: osee
1 Replies

2. AIX

ssa performances

Helo: We updated form AIX 4.3.3 to AIX 5.1-7 and after this we spent more than double time in read from external disks. Aparently the ssa cards microcode is at last level and all the ptf and apars are instaled. Out backups expent more than double time, but curiously in read only, if we write in... (0 Replies)
Discussion started by: Javier Gutierre
0 Replies

3. AIX

updating ssa

I am in the process of updating ssa adapters, drives and enclosures and wanted to know if there are any caveats that anyone would like to share. The documentation is not very clear on the ordering of the updates. Any tips would be appreciated. (1 Reply)
Discussion started by: chosie
1 Replies

4. AIX

Problem with a SSA drive

I've a problem with an IBM StorageWorks - Seagate SSA drive, model ST373453LC (IBM P/N 24P3733, Type S53D073, 72,8 GB 15K - USCSI 4 - 320 SSA). I bought this disk used but working; it came from an unknown IBM SSA storage array. I've removed the SCA - SSA adapter (IBM 18P3051 - 001 - R0) and i tried... (0 Replies)
Discussion started by: Linolinux
0 Replies

5. AIX

Location code for pdisk

Hi , I was migrating an AIX 5.2 system to AIX 5.3. I have hdisk8 and hdisk2 mirrored under rootvg. Below is the lscfg -vp output for the disks. hdisk8 U0.1-P1-I1/Q1-W40AABDDCC800D SSA Logical Disk Drive hdisk2 U0.1-P1-I1/Q1-W90D6151DEE00D SSA Logical Disk Drive I... (1 Reply)
Discussion started by: Muktesh
1 Replies

6. AIX

migrate from ssa to san

Hi, Do you have procedures to migrate ssa disks to san disk? I don't have testing environment and I want my file system be migrated one at a time. I want it to be fast, I have only 15-20 hours to do it on every sunday 1PM till monday 7am. My largest file system is about 150G. The AIX is... (0 Replies)
Discussion started by: itik
0 Replies

7. AIX

mirroring ssa to san

Hi guys, I'd like to share my migration/mirroring of ssa to san. No downtime for users, probably I/O performance. here's the step: 1 After the lun had been carved on the SAN and the connections had been done on AIX fiber card 2 “lspv” and look for the new SAN hdisk? on the bottom, say... (1 Reply)
Discussion started by: itik
1 Replies

8. AIX

Procedure for removing SSA array

Hi All, What's the proper procedure for removing SSA arrays? Is the procedure like these? - rmdev ssa disk - physical turn off the ssa - cfgmgr There's no more filesystem or logical volume on it. It's just pdisk and hdisk. Thanks in advance, itik (3 Replies)
Discussion started by: itik
3 Replies

9. AIX

VPATHS and HDisk/not able to add to NR-VG

When I list the PV's using lspv i see both vpath and hdisk names being listed. I got the info that each vpath is configured for 4 hdisks. Problem is I am not able to add either the hard disks in vpath to the existing non-rootvg. ? need to know the basics of vpath .. (4 Replies)
Discussion started by: nivaspIND
4 Replies

10. AIX

Replaced pdisk not showing up in SAS Disk Array Configuration

OSLevel: 5300-10-02-0943 System Model: IBM,8203-E4A Power 6 == Hi! I replaced a failed pdisk in the raid enclosure as follows, - rmdev -l 'pdisk18' '-d' - Replaced it. - cfgmgr (detected) - I can see the new drive, with the correct serial # lscfg -v -l pdisk18 pdisk18... (2 Replies)
Discussion started by: estrar
2 Replies
sys_attrs_tc(5) 						File Formats Manual						   sys_attrs_tc(5)

NAME
sys_attrs_tc - tc subsystem attributes DESCRIPTION
This reference page lists and describes attributes for the TURBOchannel Bus (tc) kernel subsystem. Refer to the sys_attrs(5) reference page for an introduction to the topic of kernel subsystem attributes. For this subsytem, users should modify only the following attribute and do so only for the purpose described. Any other visible attributes cannot or should not be modified. Enables (nonzero value) or disables (0) console messages that appear at boot time and runtime for use by device driver developers to collect information about a driver configuration problem. A developer can set this attribute by using the sysconfig or sysconfigdb utility. See sysconfig(8), sysconfigdb(8), and cfgmgr(8) for more information on options for modifying attributes and reconfiguring a kernel subsystem. Default value: 0 (disabled) SEE ALSO
Commands: cfgmgr(8), sysconfig(8), sysconfigdb(8) Files: stanza(4), cfgmgr.auth(4), sysconfigtab(4) Others: sys_attrs(5) Writing TURBOchannel Device Drivers sys_attrs_tc(5)
All times are GMT -4. The time now is 08:25 AM.