Check for the following:

Quote:
Determine if the StorEdge A5x00 array packages need to be installed on the nodes to which you are connecting the StorEdge A5x00 array. This product requires the following packages.

# pkginfo | egrep Wlux
system SUNWluxd Sun Enterprise Network Array sf Device Driver
system SUNWluxdx Sun Enterprise Network Array sf Device Driver (64-bit)
system SUNWluxl Sun Enterprise Network Array socal Device Driver
system SUNWluxlx Sun Enterprise Network Array socal Device Driver (64-bit)
system SUNWluxop Sun Enterprise Network Array firmware and utilities
You should be able to find info on this at the following links -
How to Add the First StorEdge A5x00 Array to a Running Cluster (yes, I realize you may not actually have a cluster - most of the info should still help)

Installing a StorEdge A5x00 Array
 

8 More Discussions You Might Find Interesting

1. Linux

Some problem about usb mass storage device

Dear linuxers, I have a usb mess storage device. My OS is rh as3 update2. Each time I use the command mount -t vfat /dev/sda1 /mnt/usb I got the error "the device is not a valid block device". I found from google that I should install the module sd_mod I use the command insmod sd_mod... (2 Replies)
Discussion started by: niukun
2 Replies

2. Shell Programming and Scripting

Problem with storage of PID's to variables

I have the following problem to be solved: I read a .csv file (tempfile), fetch the values into variables F1 to F5. Variables F1, F2, F3 are parameters used for running a program (blablaprogram). Variable F4 I want to use to store the PID-value in and variable F5 is used for storing the return... (3 Replies)
Discussion started by: zwiebertje11
3 Replies

3. Solaris

Sun storage L7 Problem

Dear Expert , We have L7 , when we power on we see on lcd messages "drive Post E" , According sun Doc SunSolve , there problem picker or Driver , I try move slot to slot successfully, On Lcd panel i can not see load drive (look like any inside tape in drive , but when i am select eject menu,... (0 Replies)
Discussion started by: hadibn
0 Replies

4. Solaris

Problem with storage

In the /var/adm/messages, i am getting the following error : Apr 16 23:49:37 inijsce1 EV_AGENT: Time Stamp 04/16/09 23:07:23 Event Number 2580 Severity Error Host inijscx33-adm Storage Array 6ASL102123 SP N/A SoftwareRev 6.19.1 (3.0) Unknown Error 2.19.0.300.5.027 Description Storage Array... (3 Replies)
Discussion started by: sundar3350
3 Replies

5. Solaris

problem with storage error

Hi gurus I don't understand the below messages as what is going on with my storage Plz kindly suggest what could be the problem Script started on Tue 12 May 2009 09:22:13 AM GMT OMP-root-/salil> uptime 9:22am up 19:44, 2 users, load average: 0.10, 0.08, 0.08 OMP-root-/salil> uname -a... (4 Replies)
Discussion started by: girish.batra
4 Replies

6. AIX

IVM Storage Virtual disk problem

Hi, When I try to create a virtual disk in IVM ( integrated Virtual Machine VIO ) I get this message Problems occurred while processing the data. A summary of all problems for this page are listed below. Additional details for each problem may be located next to the field causing the... (0 Replies)
Discussion started by: filosophizer
0 Replies

7. Hardware

320GB HD change and recognize as 2TB Problem

Hi, I would like to ask if someone experince this problem on a Hard disc. I had a 320 GB WD Blue 3.5 Hard disc. When i plug on my PC BIOS detect it for a while and dis-appear. Luckily sometimes i can check it on a bootable CD or attach on other LINUX PC but for a while it will dis-appear. As if... (3 Replies)
Discussion started by: jao_madn
3 Replies

8. IP Networking

DNS problem : ping doesn't recognize hostname

I have vmware on my windows PC ( hostname : acer ). vmware has RHEL 7 ( hostname : rhel7 ) installed recently. RHEL IP configuration IP : 192.168.5.128 Netmask : 255.255.255.0 ssh to rhel7 works from acer using putty resolve.conf cat /etc/resolv.conf nameserver 192.168.5.1 host... (12 Replies)
Discussion started by: hiten.r.chauhan
12 Replies
CISS(4) 						   BSD Kernel Interfaces Manual 						   CISS(4)

NAME
ciss -- HP/Compaq Smart ARRAY 5/6 RAID controllers SYNOPSIS
ciss* at pci? function ? DESCRIPTION
The ciss driver provides support for the CISS interface implemented by fifth and later generations of the HP/Compaq Smart ARRAY family of controllers. The CISS interface is defined in the document entitled CISS Command Interface for SCSI-3 Support Open Specification, Version 1.04, Valence Number 1, Compaq Computer Corporation, 2000/11/27. This driver supports several Compaq and HP controllers implementing the CISS interface, including: o Compaq Smart Array 5300 version 1 o Compaq Smart Array 5300 version 2 o Compaq Smart Array 5i version 1 o Compaq Smart Array 5i version 2 o HP Smart Array 5312 o HP Smart Array 6i o HP Smart Array 641 o HP Smart Array 642 o HP Smart Array 6400 o HP Smart Array 6400 EM o HP Smart Array E200 o HP Smart Array E200i o HP Smart Array P400 o HP Smart Array P400i o HP Smart Array P600 o HP Smart Array P800 o HP Smart Array V100 o HP Smart Array 1 through 13 These controllers support RAID 0, RAID 1, RAID 5, JBOD, and superpositions of those configurations. Although the controllers are actual RAID controllers, the ciss driver makes them look just like SCSI controllers. All RAID configuration must be done through the controllers' BIOSes. Hardware from previous generations of this product family may be supported by the cac(4) driver. SEE ALSO
bio(4), cac(4), intro(4), pci(4), scsi(4), sd(4) HISTORY
The ciss driver first appeared in NetBSD 3.1. AUTHORS
The ciss driver was written by Michael Shalayeff <mickey@openbsd.org>, and ported to NetBSD by Tonnerre Lombard <tonnerre@netbsd.org>. BSD
May 28, 2008 BSD
All times are GMT -4. The time now is 02:40 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy