Sponsored Content
Full Discussion: AIX varyonvg PVMISSING
Operating Systems AIX AIX varyonvg PVMISSING Post 302397452 by KSFlyer on Monday 22nd of February 2010 07:44:23 AM
Old 02-22-2010
AIX varyonvg PVMISSING

Hi all.

I'm new to AIX, so... We are running a BCV process between two AIX 5 machines attached to EMC Clariion SAN. During the varyonvg portion of the BCV process, we experienced a failure due to the physical volume is marked missing (PVMISSING). What diagnostics can I run to see the missing PV and how might I be able to fix this so the varyonvg command will run successfully?

Any and all help is greatly appreciated!
Code:
PV Status:  hdiskpower45    00cb1c7c3aa3990f        PVACTIVE
            hdiskpower16    00cb1c7c3a9c029f        PVACTIVE
            hdiskpower15    00cb1c7c3aa41ecd        PVMISSING
            hdiskpower14    00cb1c7c3a9cedd5        PVACTIVE
0516-056 varyonvg: The volume group is not varied on because a
        physical volume is marked missing. Run diagnostics.


Last edited by Scott; 02-22-2010 at 04:01 PM.. Reason: Code tags, please... easier to read.
 

9 More Discussions You Might Find Interesting

1. UNIX for Advanced & Expert Users

Unable to varyonvg

Hello all, Strange problem on p5 520 server. I've created two volume groups, filesystems, etc.. Everything working fine, without any problem. After some tests with a DS4300 unit I wanted to remove the volume groups, change the DS4300 configuration, and re-create a new volumegroup. However, I'm... (0 Replies)
Discussion started by: EricBE
0 Replies

2. AIX

How to apply aix 5.3 TL8 properly on ML5 aix system ?

Is it necessary to put system into single user mode for applying aix 5.3 TL8 on a aix 5.3.5.0 system ? Is the TL8 installation not totally safe ? thank you. (6 Replies)
Discussion started by: astjen
6 Replies

3. AIX

FastT600 - Cannot varyonvg on one server, but can varyonvg other server.

Good evening, Thanks a lot for your help, we appreciate it a bunch. Heres basically a summary of what we have (sorry Im adding some extra history as well): We have 2 Ibm Servers (Hag and Aki) that are running AIX Version 5. Each connect to a SAN device via 2 separate fiber paths. Hag seems to... (9 Replies)
Discussion started by: aix-olympics
9 Replies

4. AIX

Unable to execute varyonvg during importvg

Hello, On Aix 5.3, during importvg, the varyonvg fails: importvg -y vgtest hdisk20 0516-013 varyonvg: The volume group cannot be varied on because there are no good copies of the descriptor area. When i use manually the command varyonvg -u -b -t vgtest to force, the vg can... (3 Replies)
Discussion started by: dantares
3 Replies

5. AIX

Nim on AIX 7.1 used to migrate AIX 5.3 to AIX 6.1...is possible?

Using nimadm: nimadm -j nimadmvg -c sap024 -s spot_6100 -l lpp_6100 -d "hdisk1" -Y Initializing the NIM master. Initializing NIM client sap024. 0505-205 nimadm: The level of bos.alt_disk_install.rte installed in SPOT spot_6100 (6.1.3.4) does not match the NIM master's level (7.1.1.2).... (2 Replies)
Discussion started by: sciacca75
2 Replies

6. AIX

Unable to varyonvg after copy vg from XIV

Hi all, I am not sure whether anyone of you using XIV to copy vg from one host to another. After I managed to copy all the respective vg over to destination vg, and map all vg to destination and when come to varyonvg, I got the following error 0516-510 varyonvg: Physical volume not found for... (2 Replies)
Discussion started by: ckwan
2 Replies

7. AIX

Will it affect my AIX LPAR security, when i set up email alerts on AIX server.

Hello, I've set up email alerts on AIX Servers. so that i can get email notifications (via mail relay server) when ever there is abnormal behavior. for example 1) my script monitors CPU/disk/memory etc... when it reaches high water ark, it will send an email alert. 2) disk usage alerts 3)... (5 Replies)
Discussion started by: System Admin 77
5 Replies

8. AIX

Failed Disk,unable to varyonvg

Iam new to AIX I am unable varyonvg on the vios,some of the disk are reported as harware failure. I am going to replace the disk,Please tell me how to remove the disk without any corruption in the VG lspv -l hdiskx also didn't work (0 Replies)
Discussion started by: roayaix
0 Replies

9. AIX

Samba 3.6 on AIX 7.1 - Windows 10 Access to AIX file shares using Active Directory authentication

I am running AIX 7.1 and currently we have samba 3.6.25 installed on the server. As it stands some AIX folders are shared that can be accessed by certain Windows users. The problem is that since Windows 10 the guest feature no longer works so users have to manually type in their Windows login/pwd... (14 Replies)
Discussion started by: linuxsnake
14 Replies
vgchgid(1M)															       vgchgid(1M)

NAME
vgchgid - modify the Volume Group ID (VGID) on a given set of physical devices SYNOPSIS
PhysicalVolumePath [PhysicalVolumePath] ... DESCRIPTION
The command is designed to change the LVM Volume Group ID (VGID) on a supplied set of disks. will work with any type of storage, but it is primarily targeted at disk arrays that are able to create "snapshots" or "clones" of mirrored LUNs. accepts a set of raw physical devices and ensures that they all belong to the same volume group, before altering the VGID (see section). The same VGID is set on all the disks and it should be noted that in cases of multi-PV volume groups, all the physical volumes should be supplied in a single invocation of the command. Options recognizes the following options and arguments: PhysicalVolumePath The raw devices path name of a physical volume. Background Some storage subsystems have a feature which allows a user to split off a set of mirror copies of physical storage (termed or just as LVM splits off logical volumes with the command. As the result of the "split," the split-off devices will have the same VGID as the original disks. is needed to modify the VGID on the BCV devices. Once the VGID has been altered, the BCV disks can be imported into a new volume group by using WARNINGS
Once the VGID has been changed, the original VGID is lost until a disk device is re-mirrored with the original devices. If is used on a subset of disk devices (for example, two out of four disk devices), the two groups of disk devices would not be able to be imported into the same volume group since they have different VGIDs on them. The solution is to re-mirror all four of the disk devices and re-run on all four BCV devices at the same time, and then use to import them into the same new volume group. If a disk is newly added to an existing volume group and no subsequent LVM operations has been performed to alter the structures (in other words, operations which perform an automated vgcfgbackup(1M)); then it is possible a subsequent will fail. It will report that the disk does not belong to the volume group. This may be overcome by performing a structure changing operation on the volume group (for example, using It is the system administrator's responsibility to make sure that the devices provided in the command line are all Business Copy volumes of the existing standard physical volumes and are in the ready state and writable. Mixing the standard and BC volumes in the same volume group can cause data corruption. RETURN VALUE
returns the following values: 0 VGID was modified with no error 1 VGID was not modified EXAMPLES
An example showing how might be used: 1. The system administrator uses the following commands to create the Business Continuity (BCV or BC) copy: 1) For EMC Symmetrix disks, the commands are and 2) For XP disk array, the commands are and Three BCV disks are created. 2. Change the VGID on the BCV disks. 3. Make a new volume group using the BCV disks. This step can be skipped as the group file will be created automatically. If the file is manually created it will have different major and minor numbers (see lvm(7)). 4. Import the BCV disks into the new volume group. 5. Activate the new volume group. 6. Backup the new volume group's LVM data structure. 7. Mount the associated logical volumes. SEE ALSO
vgimport(1M), vgscan(1M), vgcfgbackup(1M). vgchgid(1M)
All times are GMT -4. The time now is 04:54 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy