09-02-2009
hi friends how we can create luns in A1OOO storage ..plzhelp its very urgent
when ever i am connect to A1000 raid controller through laptop with console cable with the help of hyperterminal..i isued serial port parameters which i mentioned below..
Set serial port parameters to:
� 38,400 baud
� 8 data bits
� 1 stop bit
� No parity
but not connecting..
for A1000 which parameters required for getting raid console..
Last edited by DukeNuke2; 09-02-2009 at 01:01 PM..
9 More Discussions You Might Find Interesting
1. UNIX for Dummies Questions & Answers
Hi,
I am a Dba and very new to filesystems and stuff.
I think that we have Veritas filesystems on my Sun SOlaris 5.8 box, how do I confirm this: all my filesystems are mounted like this:
/dev/vx/dsk...
Now we are also using disk arrays (storedge a1000) how do I access them from the system.... (1 Reply)
Discussion started by: knarayan
1 Replies
2. UNIX for Advanced & Expert Users
Hi,
I'm facing problem in connecting a Raid A1000 to E250 and E450. ( Both machines with Solaris 2.6 OS and patched, with different
scsi-initiator-ids - 7 & 3 ).
BTW, I'm not using this setup to access raid data from both machines simultaneously. There is Veritas Cluster Server monitoring... (1 Reply)
Discussion started by: shibz
1 Replies
3. UNIX for Dummies Questions & Answers
After searching and finding the link to the A1000 pdf ( http://192.18.99.138/805-7147/805-7147.pdf ) my questions are:
1) I have a battery failure on a A1000. I know that caching is disabled and it reports to see log. After reading the manual I have learned that the battery is a data-cache... (2 Replies)
Discussion started by: finster
2 Replies
4. Solaris
I have a SUN Blade 1000 running Solaris 10 and an A1000 array.
I know that this combo is not supported by SUN but will it work?
The raid manager software is installed and it says that the firmware needs to be upgraded -it is at I think level 2.05 something.
I can see all the disks in a... (13 Replies)
Discussion started by: tribbles
13 Replies
5. Solaris
Hello Experts,
I am using E250 on that solais 10 5/08 installed. I am unable to see disks. I connected 2 disks in that storage of 18gb each. When I run format command it is showing that 2 disks one is operating system and another one is 6MB. I checked probe-scsi and probe-scsi-all at ok... (6 Replies)
Discussion started by: younus_syed
6 Replies
6. Solaris
I am new to the unix world. I have SunBlade 100 and A1000 Disk storage array with 12 Hard drives. I used SCSI card and SCSI cables to connect. When I do the format command,I can see disk storage as one disk instead of 12 disks as below. Could anybody can explain why?
What should I do in order... (1 Reply)
Discussion started by: Dulasi
1 Replies
7. Solaris
I'm currently planning to improve my skills on sun disk array and deciding whether to go with sun disk array A5200 or A1000. I have found a few good systems with decent price but still can't seem to find out which one to choose. For the host system, I have 1 ultra 5 and 1 e220r system. I will most... (5 Replies)
Discussion started by: agfa_109
5 Replies
8. Solaris
I would want to ask on what software do i need to configure disk array for StorEdge A1000. (Sun Enterprise 450 - currently installed with SUN Solaris 9.)
Is it using RAID Manager 6.22? And is it compatible with SUN Solaris 9 or 10?
Thanks in advance for reading or replying my post. (2 Replies)
Discussion started by: beginningDBA
2 Replies
9. Ubuntu
Hi
I have a system running uname -a
Linux cmoveldb02 3.2.0-29-generic #46-Ubuntu SMP Fri Jul 27 17:03:23 UTC 2012 x86_64 x86_64 x86_64 GNU/Linux and I was told by the NetApp Admin that he has provided 5 LUNs of 1Tb, 200Gb and remaining 3 of 300Gb, but I am not able to see the new LUNs.
I have... (4 Replies)
Discussion started by: fretagi
4 Replies
LEARN ABOUT HPUX
fcd_disable_mgmt_lun
fcd_disable_mgmt_lun(5) File Formats Manual fcd_disable_mgmt_lun(5)
NAME
fcd_disable_mgmt_lun - select whether or not management luns are discovered in the legacy representation of mass storage devices
VALUES
Failsafe
Default
Allowed values
Enable discovery of management luns for array devices.
Disable discovery of management luns for array devices.
Recommended values
DESCRIPTION
Management luns provide the means to access the control ports of Fibre Channel disk arrays. They are represented in both the legacy and
the agile view of storage devices. The legacy representation of a management lun is typically created under a separate virtual extension
bus node. The entry for a legacy management lun looks like this:
On a system with a large number of storage devices connected, creation of management luns can result in an insufficient number of virtual
extension buses for the legacy representation of data luns. Since the number of extension buses on a system is limited to 256, luns
requiring virtual extension buses above 256 will be unusable through legacy device special files. Disabling the discovery and creation of
management luns will free up virtual extension buses for use by data luns.
The default value for this tunable is
Who Is Expected to Change This Tunable?
System administrators who expect to use a large number of storage devices requiring more than 256 extension buses through legacy device
special files.
Restrictions on Changing
Changes to this tunable take effect immediately. However, existing management luns will not be removed.
When Should the Tunable Be Turned On?
This tunable should be turned on when the system runs out of extension buses for configuring the legacy representation of data luns.
What Are the Side Effects of Turning the Tunable Off?
None.
When Should the Tunable Be Turned Off?
When the functionality provided by the management lun is desired.
What Are the Side Effects of Turning the Tunable On?
Existing management luns in the legacy representation will show up in the state.
What Other Tunables Should Be Changed at the Same Time?
None.
WARNINGS
All HP-UX kernel tunable parameters are release specific. This parameter may be removed or have its meaning changed in future releases of
HP-UX.
Installation of optional kernel software, from HP or other vendors, may cause changes to tunable parameter values. After installation,
some tunable parameters may no longer be at the default or recommended values. For information about the effects of installation on tun-
able values, consult the documentation for the kernel software being installed. For information about optional kernel software that was
factory installed on your system, see at
AUTHOR
was developed by Hewlett-Packard Company.
SEE ALSO
ioinit(1M), ioscan(1M), kctune(1M).