script to Monitor raid staus --Sun Volume manager

We use Sun Volume manager to mirror root disks and other local disks...
Is there any script to monitor raid status across all machines send output thru email?

Help is appreciated.

Thanks.
 

9 More Discussions You Might Find Interesting

1. Filesystems, Disks and Memory

Starting sun raid manager for A1000

Can anyone tell me the syntax for starting Raid manager on a A1000? (2 Replies)
Discussion started by: MBGPS
2 Replies

2. UNIX for Advanced & Expert Users

how to delete RAID of solaris volume manager thru command line

how do I remove raid that has the following Raid configuration # metastat d60: Mirror Submirror 0: d61 State: Okay Submirror 1: d62 State: Okay Pass: 1 Read option: roundrobin (default) Write option: parallel (default) Size: 36501312 blocks (17 GB) ... (1 Reply)
Discussion started by: vr76413
1 Replies

3. Solaris

How to resize mirror volume in veritas volume manager 3.5 on Solaris 9 OE

Hi all, I have a problem with vxvm volume which is mirror with two disks. when i am try to increase file system, it is throwing an ERROR: can not allocate 5083938 blocks, ERROR: can not able to run vxassist on this volume. Please find a sutable solutions. Thanks and Regards B. Nageswar... (0 Replies)
Discussion started by: nageswarb
0 Replies

4. Solaris

How can i grow Raid 5 volume in SVM..?

Hello experts.. How can i grow Raid 5 volume in SVM? Thanks in advance.. (2 Replies)
Discussion started by: younus_syed
2 Replies

5. Solaris

RAID manager or veritas volume manager

Can somebody kindly help me to determine which one i should choose to better manipulate OS volume. RAID manager or veritas volume manager? Any critical differences between those two? Thanks in advance. (5 Replies)
Discussion started by: beginningDBA
5 Replies

6. Solaris

Regarding Sun volume manager

hi all, i have a doubt. I am doing some R & D in sun volume manager. Sun solaris 5.10 is running in my sun blade 150 sparc machine. I have attached ultrascsi storage box(6x36GB hdd's) with my machine. when i create a raid 0 striping or raid 1 mirroring the output of metastat says Dbase = No. Can... (2 Replies)
Discussion started by: kingston
2 Replies

7. Shell Programming and Scripting

Script to monitor sun servers temperature

Dears, need help on developing a script to monitor sun server temperature , I'm using the below command to check the servers one by one /usr/platform/`uname -i`/sbin/prtdiag -v Servers Models are : 2 x Sun SPARC Enterprise M9000 Server 4 x Sun Fire V490 2 x Sun Blade T6300 Server... (1 Reply)
Discussion started by: bejo4ever
1 Replies

8. UNIX for Dummies Questions & Answers

VERITAS Volume Manager - mirror a disk/volume

I have a machine (5.10 Generic_142900-03 sun4u sparc SUNW,Sun-Fire-V210) that we are upgrading the storage and my task is to mirror what is already on the machine to the new disk. I have the disk, it is labeled and ready but I am not sure of the next steps to mirror the existing diskgroup and... (1 Reply)
Discussion started by: rookieuxixsa
1 Replies

9. Solaris

How to change raid layouts in veritas volume manager?

We have three disks under Raid 5. What should i do to make them Raid 0(striping)..... I mean how to change RAID layouts in VXVM ??? Please tell me with commands ..... Thanks in Advance. (0 Replies)
Discussion started by: vamshigvk475
0 Replies
vgchgid(1M)															       vgchgid(1M)

NAME
vgchgid - modify the Volume Group ID (VGID) on a given set of physical devices SYNOPSIS
PhysicalVolumePath [PhysicalVolumePath] ... DESCRIPTION
The command is designed to change the LVM Volume Group ID (VGID) on a supplied set of disks. will work with any type of storage, but it is primarily targeted at disk arrays that are able to create "snapshots" or "clones" of mirrored LUNs. accepts a set of raw physical devices and ensures that they all belong to the same volume group, before altering the VGID (see section). The same VGID is set on all the disks and it should be noted that in cases of multi-PV volume groups, all the physical volumes should be supplied in a single invocation of the command. Options recognizes the following options and arguments: PhysicalVolumePath The raw devices path name of a physical volume. Background Some storage subsystems have a feature which allows a user to split off a set of mirror copies of physical storage (termed or just as LVM splits off logical volumes with the command. As the result of the "split," the split-off devices will have the same VGID as the original disks. is needed to modify the VGID on the BCV devices. Once the VGID has been altered, the BCV disks can be imported into a new volume group by using WARNINGS
Once the VGID has been changed, the original VGID is lost until a disk device is re-mirrored with the original devices. If is used on a subset of disk devices (for example, two out of four disk devices), the two groups of disk devices would not be able to be imported into the same volume group since they have different VGIDs on them. The solution is to re-mirror all four of the disk devices and re-run on all four BCV devices at the same time, and then use to import them into the same new volume group. If a disk is newly added to an existing volume group and no subsequent LVM operations has been performed to alter the structures (in other words, operations which perform an automated vgcfgbackup(1M)); then it is possible a subsequent will fail. It will report that the disk does not belong to the volume group. This may be overcome by performing a structure changing operation on the volume group (for example, using It is the system administrator's responsibility to make sure that the devices provided in the command line are all Business Copy volumes of the existing standard physical volumes and are in the ready state and writable. Mixing the standard and BC volumes in the same volume group can cause data corruption. RETURN VALUE
returns the following values: 0 VGID was modified with no error 1 VGID was not modified EXAMPLES
An example showing how might be used: 1. The system administrator uses the following commands to create the Business Continuity (BCV or BC) copy: 1) For EMC Symmetrix disks, the commands are and 2) For XP disk array, the commands are and Three BCV disks are created. 2. Change the VGID on the BCV disks. 3. Make a new volume group using the BCV disks. This step can be skipped as the group file will be created automatically. If the file is manually created it will have different major and minor numbers (see lvm(7)). 4. Import the BCV disks into the new volume group. 5. Activate the new volume group. 6. Backup the new volume group's LVM data structure. 7. Mount the associated logical volumes. SEE ALSO
vgimport(1M), vgscan(1M), vgcfgbackup(1M). vgchgid(1M)
All times are GMT -4. The time now is 05:02 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy