Sponsored Content
Top Forums UNIX for Advanced & Expert Users remote startup of login & sessions Post 29933 by witt on Monday 14th of October 2002 02:18:27 PM
Old 10-14-2002
If you put your workstation in a Terminal Concentrator, like Anexx, you can start a telnet session to the serial port of the workstation B, and start it...

Witt
witt
 

10 More Discussions You Might Find Interesting

1. AIX

AIX Login sessions

In AIX v5.2 is there a way to restrict the number of telnet sessions for a particular user ? Say, i want restrict the number of simultaneous telnet session for a particular user to be 3. How do i achieve this. Appreicate your help (1 Reply)
Discussion started by: rramanuj
1 Replies

2. Solaris

Solaris 10x86, How to get remote X sessions to work?

I just installed Solaris 10 - 10/08 x86 and want to be able to connect remotely from either my other Sparc Sun box or Xwin32 or Cygwin-X to it. For some reason unlike my Solaris 10 Sparc install the X for remote does not seem to be running or working properly. What do I need to do to make this work... (5 Replies)
Discussion started by: lacakid
5 Replies

3. Shell Programming and Scripting

Open n number of remote sessions

I m need of something useful to reduce my n number of login sessions to save my time. Scenario : I will login 40+ servers daily with ip address. i hv generated ssh key gens in order to avoid passwords. what i need is : when i click a terminal, i need these 40 servers logged in... (1 Reply)
Discussion started by: anand.linux1984
1 Replies

4. Linux

Max Number of remote X sessions

Hello all, I'm looking to implement a Linux server that will host up to 60 simultaneous X sessions, all running firefox to a secured web interface. Does anyone have any experience sizing a system like this? The reason for the setup isn't as important (Since I really don't understand why... (1 Reply)
Discussion started by: ZekesGarage
1 Replies

5. Linux

Unable to login with root for more than 2 sessions

Hi, I am unable to login with root for more than 2 sessions. Plz help any thing need to updated? Suresh (2 Replies)
Discussion started by: suresh3566
2 Replies

6. UNIX for Dummies Questions & Answers

Automatic login at startup

Hi, how can I set my linux server that it logs in the main user at startup? I would like to be able to make a restart remotely and be able to connect to the server again afterwards. The problem is that the server waits for a login and than connects to the network. So at the beginning at... (5 Replies)
Discussion started by: borobudur
5 Replies

7. Solaris

how to login with ssh to remote system with out applying the remote root/usr password

how to login with ssh to remote system with out applying the remote root/user password with rlogin we can ujse .rhosts file but with ssh howits possible plz guide (2 Replies)
Discussion started by: tv.praveenkumar
2 Replies

8. Solaris

Logging remote telnet sessions via script

Hi, My requirement - for security purpose - I want all root logins to my solaris servers are done by a script kept in a separate unix box. This script will telnet into remote solaris server with root user and log every session via log file. Now my purpose is to log every telnet session... (3 Replies)
Discussion started by: rahul_jain250
3 Replies

9. AIX

3004-312 All available login sessions are in use.

Hello, I have a strange situation here. I am running an AIX6.1 machine and i face a problem when i am trying to login via telnet. When i use my username and password to login to the server i get the following message: 3004-312 All available login sessions are in use. The weird thing is that... (3 Replies)
Discussion started by: omonoiatis9
3 Replies

10. UNIX for Beginners Questions & Answers

What will be the effect of environment variable, when mulitple sessions are opened by same login?

Hello, What will be the effect of environment variable, when mulitple sessions are opened by same login? Following code snippet is part of a shell script. Environment : HP-UX B.11.31 U ia64 For Example EXECUTION_DIR=`pwd`/ EXECUTION_DIR_RT=${EXECUTION_DIR}RT/ export... (4 Replies)
Discussion started by: Siva SQL
4 Replies
AX25D.CONF(5)						     Linux Programmer's Manual						     AX25D.CONF(5)

NAME
ax25d.conf - ax25d configuration file. DESCRIPTION
Ax25d.conf controls the functioning of ax25d. Its purpose is to specify on which ports to listen on, which applications are available, and to whom they are available to. The configuration file is common to both AX.25, NET/ROM and Rose and their is similarity between the two parts of the file. The general layout for an entry for a given port is as follows: interface control callsign entry 1 . . callsign entry n The interface control line determines which port and callsigns apply to the following callsign entry lines, until the next interface con- trol is read. There are four different variants of the interface control line: 1. [AX.25 Port Name] 2. [Callsign VIA AX.25 Port Name] 3. <NET/ROM Port Name> 4. {Callsign VIA Rose Port Name} Version 1 allows the following callsign entry lines to listen on the AX.25 port specified by the AX.25 port name using the default callsign of that AX.25 port. Version 2 allows the following callsign entry lines to listen on the AX.25 port specified by the AX.25 port name using the callsign speci- fied instead of the default callsign of that AX.25 port. Specifying a * for the AX.25 port name allows the following callsign entries to be valid for all the operating AX.25 ports using the callsign specified. VIA can be abbreviated to just V. If the callsign has an asterisk appended to it then the system will be listening on the port with the callsign, but as a pseudo-digipeater instead of being the normal des- tination callsign. Version 3 allows the following callsign entry lines to listen on the NET/ROM port specified by the NET/ROM port name using the default callsign of that NET/ROM port. Version 4 allows the following callsign entry lines to listen on the Rose port using the specified Rose port name using the callsign speci- fied as the service access point (SAP). A * may be specified for a callsign to allow matching to any incoming Call Requests with any SAP. The callsign entry lines have a similar layout for both AX.25, NET/ROM and Rose, the layout is: peer window t1 t2 t3 idle n2 mode uid exec args... All values must be entered for all entries even when they are not used (ie window for NET/ROM, just enter a * instead), The meanings of each of the fields is given below. All timings apart from the idle value are given in seconds, the idle values is given in minutes. peer This specifies the callsign of the remote end of the connection that should have the following parameters and executable set up for them. The syntax of the peer argument is explained below. window This sets the the value of the window size, if a value of * is entered in this field then the default value for the port is taken from the "parameters" entry (see below) or lacking such an entry, the kernel default value is used. This entry is used by AX.25 but not by NET/ROM or Rose. t1 This sets the the value of the T1 timer, if a value of * is entered in this field then the default value for the port is taken from the "parameters" entry (see below) or lacking such an entry, the kernel default value is used. This entry is used by both AX.25 and NET/ROM but not by Rose. t2 This sets the the value of the T2 timer, if a value of * is entered in this field then the default value for the port is taken from the "parameters" entry (see below) or lacking such an entry, the kernel default value is used. This entry is used by both AX.25 and NET/ROM but not by Rose. t3 This sets the the value of the T3 timer, if a value of * is entered in this field then the default value for the port is taken from the "parameters" entry (see below) or lacking such an entry, the kernel default value is used. This entry is used by AX.25 but not by NET/ROM or Rose. idle This sets the the value of the idle timer, if a value of * is entered in this field then the default value for the port is taken from the "parameters" entry (see below) or lacking such an entry, the kernel default value is used. n2 This sets the the value of the N2 counter, if a value of * is entered in this field then the default value for the port is taken from the "parameters" entry (see below) or lacking such an entry, the kernel default value is used. This entry is used by both AX.25 and NET/ROM but not by Rose. mode This is a set of flags that control the various properties associated with the incoming connection. The flags are single letters, may be in either upper or lower case, and there may not be any spaces between them. If no flags are to be speci- fied either a 0, - or a * must be entered instead. The valid mode flag letters are: D Do not allow connections that have passed via any digipeaters. AX.25 only. L Do not allow this station to connect, they are Locked out. N Check that the NET/ROM neighbour is allowed, currently unused. Q Do not make an entry into the log file for this connection. V Validate the callsign of the incoming connection, currently unused. uid This is the userid that the following command should run under when executing. exec This is the executable that should be executed when an incoming connection matches the criteria of both the interface con- trol and the callsign entry . args... These are the optional arguments that are passed to the executable. All of the arguments are passed literally apart from the following: %d The name of the port that the connection is on. %U The username (callsign) of the remote station in upper case without the SSID. %u The username (callsign) of the remote station in lower case without the SSID. %S The username (callsign) of the remote station in upper case with the SSID. %s The username (callsign) of the remote station in lower case with the SSID. %P The nodename of the remote station in upper case without the SSID. This is only valid under NET/ROM and Rose, under AX.25 a % is substituted instead. %p The nodename of the remote station in lower case without the SSID. This is only valid under NET/ROM and Rose, under AX.25 a % is substituted instead. %R The nodename of the remote station in upper case with the SSID. This is only valid under NET/ROM and Rose, under AX.25 a % is substituted instead. %r The nodename of the remote station in lower case with the SSID. This is only valid under NET/ROM and Rose, under AX.25 a % is substituted instead. %% A %. The peer argument is dependant upon whether AX.25, NET/ROM or Rose is being used. There are five formats of this argument: 1. default 2. parameters 3. callsign 4. callsign@node 5. @node The first version is used by AX.25, NET/ROM and Rose to specify that all callsigns on a given port are to be matched. The default line is usually the last of the callsign entry lines, so that more specific entries may have the chance to be matched first. The second version is not a callsign entry that is used by any incoming connections. It is a means to specify default values for parameters such as Window, T1, T2, T3, Idle and N2. It is used for both AX.25, NET/ROM and Rose. The third version is used by both AX.25, NET/ROM and Rose to specify the callsign of the remote station to match the callsign entry line. If no SSID is specified then the callsign will be matched with any that has the same callsign and any SSID. Specifying an SSID causes the callsign to be matched exactly. In the case of NET/ROM and Rose this entry does not specify which node the originating callsign comes from. The fourth version is used by NET/ROM and Rose to specify the callsign of the remote station and the remote node to match the callsign entry line. If no SSID is specified in the callsign section then the callsign will be matched with any that has the same callsign and any SSID. Specifying an SSID causes the callsign to be matched exactly. The fifth version is used by NET/ROM and Rose to specify only the address of the remote node to match the callsign entry line. This entry will mean that all remote users at the given node will match the entry. Comments may be embedded in the configuration file by placing a # in the first column. ax25d can now honour AX.25 TCP/IP mode-VC connections in a special way. Therefore, a new port specific option "parameters_extAX25" is available, with the following options, which are seperated by space. parameters_extAX25 VC-debug VC-reject-login|VC-wait-login|VC-login-ok VC-disc-on-linkfailure-msg, VC-send-failure-msg, VC-log-connections Recommended settings in ax25d.conf: parameters_extAX25 VC-wait-login VC-disc-on-linkfailure-msg VC-log-connections or parameters_extAX25 VC-reject-login VC-send-failure-msg VC-log-connections FILES
/etc/ax25/ax25d.conf SEE ALSO
ax25(4), netrom(4), rose(4), axports(5), nrports(5), rsports(5), ax25d(8). Linux 17 January 1997 AX25D.CONF(5)