09-15-2002
was it crashed physically ? or just partitioning problems ? i dont get a thing
10 More Discussions You Might Find Interesting
1. UNIX for Dummies Questions & Answers
Hi All,
When I came officce this morning I saw this error messages on the screen
-----
PANIC:srmountfun - Error 6 mounting rootdev hd (1/42)
Cannot dump 32639 pages to dumpdev hd (1/41) : space for only 0 pages
Dump not completed
--------
and machine was reboot mode. Why this problem... (3 Replies)
Discussion started by: alisev
3 Replies
2. SCO
Hi Friends ,
i am getting the following error when iam booting a sco unix system.
------------------
H init
PANIC : srmountfun --Error 22 mounting rootdev hd(1/42)
cannot dump 40863 pages to dempdev hd(1/41) : space for only 0 pages.
Dump not completed.
Safe to power off.... (1 Reply)
Discussion started by: sveera
1 Replies
3. Red Hat
helo,
my system is runing on redhat 9.0.
but now when i run my machine i got the following error.
Kernel Panic:No init found.
try passing init = option to kernel.
i dont have any idea about linux administration.
can u help me to solve this error
Thanks and Regards,... (2 Replies)
Discussion started by: amitpansuria
2 Replies
4. Linux
Hi all,
I am new to redhat/fedora linux.
In fedora linux 6,we created one file system(hda3 - /fs).
in this mount poing we were installed mounta vista os.
while booting we are getting below error messages.
1)
Booting 'mountaVisat(2.6.18_pro 500_pc_target-x86_586 smp)'
root(hd0,1)... (2 Replies)
Discussion started by: arjunreddy3
2 Replies
5. Solaris
HI friends
can any body tell me what is the difference between server panic and fatal error. (1 Reply)
Discussion started by: tv.praveenkumar
1 Replies
6. SCO
hi
I've virtualized physical SCO 5.0.6 on ESX 4 according to:
Blog du DS45: HOWTO SCO P2V in the real life
SCO starts with the network, but during shutdown I'm getting this message:
PANIC: k_trap.
My /etc/default/boot:
# cat /etc/default/boot
#ScoAdminInit BOOTMNT {RO RW NO} RO... (4 Replies)
Discussion started by: ccc
4 Replies
7. Red Hat
Hi Guys,
I'm working with a down RedHat Server. Whenever the server tries to boot, there's an error stating:
Kernel panic: No init found. Try passing init= option to kernel.
In addition to this, the "Caps Lock" and "Scroll Lock" lights start flashing. The server doesn't boot pass this... (1 Reply)
Discussion started by: bbbngowc
1 Replies
8. Solaris
A server that I am working on (SUN FIRE V240 , SOLARIS 10) doesn't boot because of a corrupted files system.
I tried to repair de file system, I also tried to to restore all the files systems with a backup of the server that I have but the message bellow appear
panic/thread=30002fc2060:... (8 Replies)
Discussion started by: feg
8 Replies
9. Solaris
Hi All,
I am getting the below error after login to box.
SunOS Release 5.10 Version Generic_147440-02 64-bit
Copyright (c) 1983, 2011, Oracle and/or its affiliates. All rights reserved.
os-io Cross trap sync timeout: at cpu_sync.xword: 0x1010panic: failed to sto
p cpu8
panic: failed to... (1 Reply)
Discussion started by: chetansingh23
1 Replies
10. Red Hat
HI All,
server stopped here, we are suspecting server crash, need install new OS.
Any suggestions on this. kindly help to us.
Thanks
Rajesh (0 Replies)
Discussion started by: Rajesh_Apple
0 Replies
CISS(4) BSD Kernel Interfaces Manual CISS(4)
NAME
ciss -- HP/Compaq Smart ARRAY 5/6 RAID controllers
SYNOPSIS
ciss* at pci? function ?
DESCRIPTION
The ciss driver provides support for the CISS interface implemented by fifth and later generations of the HP/Compaq Smart ARRAY family of
controllers.
The CISS interface is defined in the document entitled CISS Command Interface for SCSI-3 Support Open Specification, Version 1.04, Valence
Number 1, Compaq Computer Corporation, 2000/11/27.
This driver supports several Compaq and HP controllers implementing the CISS interface, including:
o Compaq Smart Array 5300 version 1
o Compaq Smart Array 5300 version 2
o Compaq Smart Array 5i version 1
o Compaq Smart Array 5i version 2
o HP Smart Array 5312
o HP Smart Array 6i
o HP Smart Array 641
o HP Smart Array 642
o HP Smart Array 6400
o HP Smart Array 6400 EM
o HP Smart Array E200
o HP Smart Array E200i
o HP Smart Array P400
o HP Smart Array P400i
o HP Smart Array P600
o HP Smart Array P800
o HP Smart Array V100
o HP Smart Array 1 through 13
These controllers support RAID 0, RAID 1, RAID 5, JBOD, and superpositions of those configurations.
Although the controllers are actual RAID controllers, the ciss driver makes them look just like SCSI controllers. All RAID configuration
must be done through the controllers' BIOSes.
Hardware from previous generations of this product family may be supported by the cac(4) driver.
SEE ALSO
bio(4), cac(4), intro(4), pci(4), scsi(4), sd(4)
HISTORY
The ciss driver first appeared in NetBSD 3.1.
AUTHORS
The ciss driver was written by Michael Shalayeff <mickey@openbsd.org>, and ported to NetBSD by Tonnerre Lombard <tonnerre@netbsd.org>.
BSD
May 28, 2008 BSD