Sponsored Content
Special Forums Hardware Filesystems, Disks and Memory Starting sun raid manager for A1000 Post 27710 by RTM on Thursday 5th of September 2002 12:25:46 PM
Old 09-05-2002
For starting the GUI interface - /usr/lib/osa/bin/rm6 but it all has to be configured before starting that....


check out the documentation at Sun Docs - Raid Manager Software and RAID Manager Install / Support Guide
 

8 More Discussions You Might Find Interesting

1. UNIX for Advanced & Expert Users

Raid A1000 with E450 and E250.

Hi, I'm facing problem in connecting a Raid A1000 to E250 and E450. ( Both machines with Solaris 2.6 OS and patched, with different scsi-initiator-ids - 7 & 3 ). BTW, I'm not using this setup to access raid data from both machines simultaneously. There is Veritas Cluster Server monitoring... (1 Reply)
Discussion started by: shibz
1 Replies

2. Filesystems, Disks and Memory

Moving Sun A1000 between E450's

Does anyone know what steps I have to follow to move an A1000 between two E450's. Im running solaris 2.6 (1 Reply)
Discussion started by: MBGPS
1 Replies

3. UNIX for Dummies Questions & Answers

Ultra60 and A1000....raid manager needed just to see it?

Hi guys, I was asked to setup an Ultra60 (Sol 8) with an StorEdge A1000. Does anyone know if a probe-scsi-all is suppose to detect it? Right now it doesn't, so maybe I answered my own question :rolleyes: We have an the same setup running already, but I wasn't around when that was setup. ... (3 Replies)
Discussion started by: Yinzer955i
3 Replies

4. UNIX for Advanced & Expert Users

how to delete RAID of solaris volume manager thru command line

how do I remove raid that has the following Raid configuration # metastat d60: Mirror Submirror 0: d61 State: Okay Submirror 1: d62 State: Okay Pass: 1 Read option: roundrobin (default) Write option: parallel (default) Size: 36501312 blocks (17 GB) ... (1 Reply)
Discussion started by: vr76413
1 Replies

5. UNIX for Advanced & Expert Users

script to Monitor raid staus --Sun Volume manager

We use Sun Volume manager to mirror root disks and other local disks... Is there any script to monitor raid status across all machines send output thru email? Help is appreciated. Thanks. (1 Reply)
Discussion started by: sriny
1 Replies

6. Filesystems, Disks and Memory

Poor read performance on sun storedge a1000

Hello, i have a a1000 connected to an e6500. There's a raid 10 (12 disks) on the a1000. If i do a dd if=/dev/zero of=/mnt/1 bs=1024k count=1000 and then look at iostat it tells me there's a kw/s of 25000. But if i do a dd of=/dev/zero if=/mnt/1 bs=1024k count=1000 then i see only a... (1 Reply)
Discussion started by: mbrenner
1 Replies

7. Solaris

RAID manager or veritas volume manager

Can somebody kindly help me to determine which one i should choose to better manipulate OS volume. RAID manager or veritas volume manager? Any critical differences between those two? Thanks in advance. (5 Replies)
Discussion started by: beginningDBA
5 Replies

8. Solaris

How to change raid layouts in veritas volume manager?

We have three disks under Raid 5. What should i do to make them Raid 0(striping)..... I mean how to change RAID layouts in VXVM ??? Please tell me with commands ..... Thanks in Advance. (0 Replies)
Discussion started by: vamshigvk475
0 Replies
httppower(8)							     powerman							      httppower(8)

NAME
httppower - communicate with HTTP based power distribution units SYNOPSIS
httppower [--url URL] DESCRIPTION
httppower is a helper program for powerman which enables it to communicate with HTTP based power distribution units. It is run interac- tively by the powerman daemon. OPTIONS
-u, --url URL Set the base URL. INTERACTIVE COMMANDS
The following commands are accepted at the httppower> prompt: auth user:pass Authenticate to the base URL with specified user and password, using ``basic'' HTTP authentication which sends the user and password over the network in plain text. seturl URL Set the base URL. Overrides the command line option. get [URL-suffix] Send an HTTP GET to the base URL with the optional URL-suffix appended. post [URL-suffix] key=val[&key=val]... Send an HTTP POST to the base URL with the optional URL-suffix appended, and key-value pairs as argument. FILES
/usr/sbin/httppower /etc/powerman/powerman.conf ORIGIN
PowerMan was originally developed by Andrew Uselton on LLNL's Linux clusters. This software is open source and distributed under the terms of the GNU GPL. SEE ALSO
powerman(1), powermand(8), httppower(8), plmpower(8), vpcd(8), powerman.conf(5), powerman.dev(5), powerman-devices(7). http://sourceforge.net/projects/powerman powerman-2.3.5 2009-02-09 httppower(8)
All times are GMT -4. The time now is 01:24 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy