First time writer....take it easy on me.

I had a situation where I lost all paths to EMC disk. There was a failure on the EMC frame. After that was repaired, my server had a difficult time reclaiming all disks and veritas had marked the disks as failed. Veritas was confused. What are some of the files that need to be cleaned up with veritas so that these disks no longer appear as failed?

SERVERNAME:/root# vxdisk list | grep fail
- - datadg02 datadg failed was:c4t30d1s2



I tried a reboot reconfigure but it wasnt helping. It wouldnt reconfigure all the disks.

Running VRTS 4.1 with Solaris 5.8 kernel patch level 117350-29.

If you need more info on the system, let me know.

Thanks.

-S
 
Login or Register to Ask a Question

Previous Thread | Next Thread

10 More Discussions You Might Find Interesting

1. Solaris

Reclaiming space SVM

Hi I have a solaris 10 server, that we no longer will be used, and the system has it storage on the NetApp. Most of the file systems that I have already umounthave the following entry on /etc/vfstab: df -h /ora* Filesystem size used avail capacity Mounted on /dev/md/dsk/d400... (2 Replies)
Discussion started by: fretagi
2 Replies

2. Solaris

Modifying properties to use scsi-3 reservation for disks with two paths in sun cluster

Hi I am having two node cluster. I was trying to change the to use scsi3 reservation for all disks having two paths. Please let me know where I went wrong or there any issue to implement the same. On node1 bash-3.2# cldev status === Cluster DID Devices === Device Instance ... (8 Replies)
Discussion started by: sb200
8 Replies

3. UNIX for Dummies Questions & Answers

Losing Time

Our Unix system is losing a considerable amount of time each day, and our support service company says our motherboard is the cause. They "upgraded" us 5 years ago to basically the same thing as what we had previously, and are looking to "upgrade" us again now for about $5,000... I think... (23 Replies)
Discussion started by: Big Z
23 Replies

4. Forum Support Area for Unregistered Users & Account Problems

Losing the connection

Hi. Recently when I'm logged in to site after some seconds, for instance, I lose the connection and need sign in again. It happens on Firefox and Chrome. Or another example, when I'm logged in to site and click on my nick name (right up corner) I lose the connection to site. User: tiago ... (0 Replies)
Discussion started by: Unregistered
0 Replies

5. Emergency UNIX and Linux Support

losing ESSID

Hey guys, facing a weird issue - hoping someone might be able to help. The wireless network on my laptop is configured with a static IP address. (not using nm) When i take the laptop out of the range (or i power the router down) the essid is becoming "off/any". When i'm back in range the... (6 Replies)
Discussion started by: moshe88
6 Replies

6. Shell Programming and Scripting

Losing zero in while read

I'm using a while read statement to read in lines from a file, if a value (for example) is 1000.10 in a field, the last zero is removed leaving 1000.1 does anyone know a way to keep the field as it is in the original file? (1 Reply)
Discussion started by: gefa
1 Replies

7. Solaris

Problems fetching EMC disks to Solaris OS.

Hi, I have a nasty little problem with my disks on my system My system configuration is as follows Sunv890 with sunos 9 connected tot a IBM6800 SAN using a 2port 2 GB qla2342 adapter. We have bought a EMC SAN. The company who sold us the san, said that it would be no problem connecting the... (10 Replies)
Discussion started by: orac
10 Replies

8. AIX

Configurin EMC SAN disks on AIX

This may sound like an absolute rookie question, and it is. I have been working on Migrating our HP and Solaris servers to the new EMC SAN and know the routines backwards. Now we've suddenly got a new IBM server and I don't even know how to check if it is connected to the switch. Can someone... (1 Reply)
Discussion started by: ronellevan
1 Replies

9. Solaris

Emc

Dear gentelmen kindly please update me me how can i know disks on EMC and get size for all disks on EMC? (1 Reply)
Discussion started by: magasem
1 Replies

10. UNIX for Dummies Questions & Answers

losing time

Hi all, The server seems to be losing time, not a lot, but enough to be noticed. UNIX AIX 4.3.3 Any ideas, Kathy (9 Replies)
Discussion started by: kburrows
9 Replies
Login or Register to Ask a Question
vgchgid(1M)															       vgchgid(1M)

NAME
vgchgid - modify the Volume Group ID (VGID) on a given set of physical devices SYNOPSIS
PhysicalVolumePath [PhysicalVolumePath] ... DESCRIPTION
The command is designed to change the LVM Volume Group ID (VGID) on a supplied set of disks. will work with any type of storage, but it is primarily targeted at disk arrays that are able to create "snapshots" or "clones" of mirrored LUNs. accepts a set of raw physical devices and ensures that they all belong to the same volume group, before altering the VGID (see section). The same VGID is set on all the disks and it should be noted that in cases of multi-PV volume groups, all the physical volumes should be supplied in a single invocation of the command. Options recognizes the following options and arguments: PhysicalVolumePath The raw devices path name of a physical volume. Background Some storage subsystems have a feature which allows a user to split off a set of mirror copies of physical storage (termed or just as LVM splits off logical volumes with the command. As the result of the "split," the split-off devices will have the same VGID as the original disks. is needed to modify the VGID on the BCV devices. Once the VGID has been altered, the BCV disks can be imported into a new volume group by using WARNINGS
Once the VGID has been changed, the original VGID is lost until a disk device is re-mirrored with the original devices. If is used on a subset of disk devices (for example, two out of four disk devices), the two groups of disk devices would not be able to be imported into the same volume group since they have different VGIDs on them. The solution is to re-mirror all four of the disk devices and re-run on all four BCV devices at the same time, and then use to import them into the same new volume group. If a disk is newly added to an existing volume group and no subsequent LVM operations has been performed to alter the structures (in other words, operations which perform an automated vgcfgbackup(1M)); then it is possible a subsequent will fail. It will report that the disk does not belong to the volume group. This may be overcome by performing a structure changing operation on the volume group (for example, using It is the system administrator's responsibility to make sure that the devices provided in the command line are all Business Copy volumes of the existing standard physical volumes and are in the ready state and writable. Mixing the standard and BC volumes in the same volume group can cause data corruption. RETURN VALUE
returns the following values: 0 VGID was modified with no error 1 VGID was not modified EXAMPLES
An example showing how might be used: 1. The system administrator uses the following commands to create the Business Continuity (BCV or BC) copy: 1) For EMC Symmetrix disks, the commands are and 2) For XP disk array, the commands are and Three BCV disks are created. 2. Change the VGID on the BCV disks. 3. Make a new volume group using the BCV disks. This step can be skipped as the group file will be created automatically. If the file is manually created it will have different major and minor numbers (see lvm(7)). 4. Import the BCV disks into the new volume group. 5. Activate the new volume group. 6. Backup the new volume group's LVM data structure. 7. Mount the associated logical volumes. SEE ALSO
vgimport(1M), vgscan(1M), vgcfgbackup(1M). vgchgid(1M)