06-15-2004
If no one has an answer or encoutered the same problem, can someone suggest a back up device with capacity for 20 gig that will work on a Compaq proliant 1600r runing SCO 505.
8 More Discussions You Might Find Interesting
1. IP Networking
Right now, i have an SCO 505 with IP, GATEWAY e MASK configured.
I have one router that is my gateway.
The SCO is able to connect to all of the local computers, including the router.
However, i´m not unable to ping anything that is not local with SCO.
I believe I tried setting the... (1 Reply)
Discussion started by: Danielnr
1 Replies
2. UNIX for Advanced & Expert Users
Hi guys
I had a system running 5.0.6 , we upgraded it to 5.0.7 everything was fine till i try to do a test backup.
The error was cannot open (cannot open /dev/xct0 no such file or directory)what i did was, removed the tape , reboot the system and the try to install it again, but its... (2 Replies)
Discussion started by: josramon
2 Replies
3. UNIX for Dummies Questions & Answers
I have installed vnc on my SCO 505 box. its running fin, but when I start a session and connect to it from my win machine I do get an Xsession but I only get an xterm and thats it. I know my settings are in my //.vnc/xstartup file but what exactly am I supposed to see there.
will some one send... (3 Replies)
Discussion started by: franruiz
3 Replies
4. SCO
Hi
Don't know if anyone will be able to help, but we're currently having problems with our external tape drive on our SCO server. If I try the following command for instance, "tar cvf /dev/rStp0", the tape drive jumps into action for a while, then comes back with the error "tar: cannot open:... (3 Replies)
Discussion started by: mattingg
3 Replies
5. UNIX for Dummies Questions & Answers
hi guys,
I.m trying to remove and add a new tape drive by using the mkdev tape command and when i try to update the Kernel this is what i'm getting,
i386ld: Symbol Sdsk_no_tag in /var/opt/K/SCO/link/1.1.1Eb/etc/conf/pack.d/blad/s
pace.o is multiply defined. First defined in... (0 Replies)
Discussion started by: josramon
0 Replies
6. SCO
Situation - i have an IDE hard drive from server apparently running SCO last used in 2003. No access to computer it was formerly in. I need to access the drive to pull off data files from a billing/scheduling program. I have no SCO machine or access to one atm. Have some limited Linux... (3 Replies)
Discussion started by: lordlars1
3 Replies
7. SCO
Hi,
Does anyone know if a HP VS160 Tape drive will work with SCO Openserver Release 5?
If so what driver would it use? alad, cha?
Thanks
John (3 Replies)
Discussion started by: jfd7000
3 Replies
8. SCO
Our tape drive died and I installed a newer Quantum DAT72 drive in it's place with the same SCSI ID. It still works, but with one major flaw, the system will lock up if I try to upgrade BackupEDGE or view NFS settings in scoadmin.
I get a Transition to ready failure on ha=0* message when the... (4 Replies)
Discussion started by: psytropic
4 Replies
TS(4) Kernel Interfaces Manual TS(4)
NAME
ts - TS-11 magtape interface
SYNOPSIS
/sys/conf/SYSTEM:
NTS ts_drives # TS11
/etc/dtab:
#Name Unit# Addr Vector Br Handler(s) # Comments
ts ? 172520 224 5 tsintr # ts11 driver
major device number(s):
raw: 8
block: 2
minor device encoding:
bits 0003 specify TS drive
bit 0004 specifies no-rewind operation
bit 0010 ignored
DESCRIPTION
The ts-11 combination provides a standard tape drive interface as described in mtio(4). The ts-11 operates only at 1600 bpi, and only one
transport is possible per controller.
FILES
/dev/MAKEDEV script to create special files
/dev/MAKEDEV.local script to localize special files
SEE ALSO
mt(1), tar(1), tp(1), mtio(4), ht(4), tm(4), dtab(5), autoconfig(8)
DIAGNOSTICS
ts%d: no write ring. An attempt was made to write on the tape drive when no write ring was present; this message is written on the termi-
nal of the user who tried to access the tape.
ts%d: not online. An attempt was made to access the tape while it was offline; this message is written on the terminal of the user who
tried to access the tape.
ts%d: hard error bn%d xs0=%b xs1=%b xs2=%b xs3=%b. A hard error occurred on the tape at block bn; status registers 0-3 are printed in
octal and symbolically decoded as bits.
ts%d: addr mod 4 != 0. The address of a TS-11 command packet was not on an even longword boundary.
BUGS
If any non-data error is encountered on non-raw tape, it refuses to do anything more until closed.
The device lives at the same address as a tm-11 tm(4).