Sponsored Content
Operating Systems Solaris Sun Fire v440 Hard disk or controller broken? WARNING: /pci@1f,700000/scsi@2/sd@0,0 (sd1) Post 303044060 by oliwei on Thursday 13th of February 2020 05:42:49 AM
Old 02-13-2020
Do I need to issue a command in order to remove one of the disks? Is the raid hotplug capable?
 

10 More Discussions You Might Find Interesting

1. Solaris

Sun Fire V440 and Patch 109147-39

Got an curious issue. I applied 109147-39 to, oh 15 or so various systems all running Jumpstarted Solaris 8. When I hit the first two V440s, they both failed with Return code 139. All non shell commands segfaulted from then on. The patch modified mainly the linker libraries and commands. ... (2 Replies)
Discussion started by: BOFH
2 Replies

2. Solaris

Sun Fire v440 keeps shutting down

Hello, I hope you can help me. I am new to Sun servers and we have a Sun Fire v440 server in which one power supply failed, we are waiting for new one. But now our server is shutting down constantly. Is there any setting with which we can prevent this behaviour? (1 Reply)
Discussion started by: Tibor
1 Replies

3. Solaris

USB Hard Disk Drive Supported by Sun Fire V890

Hi, Can anyone suggest me any USB Hard Disk Drive which I can connect to Sun Fire V890 and take backup at a quick speed. A test with SolidState USB Hard Drive for backup work was taking writing at 2GB per hour for a 75GB backup. Regards, Tushar Kathe (1 Reply)
Discussion started by: tushar_kathe
1 Replies

4. Solaris

Sun Fire v440 hardware problem (can't get ok>)

First of all it's shut down 60 second after power on and write on console : SC Alert: Correct SCC not replaced - shutting managed system down! This is cured by moving out battery from ALOM card. Now server start to loop during the testing. That's on the console: >@(#) Sun Fire V440,Netra... (14 Replies)
Discussion started by: Alisher
14 Replies

5. Solaris

error messages in Sun Fire V440

Hello, I am seeing error messages in V440 (OS = solaris 8). I have copied here : The system does not reboot constantly and it is up for last 67 days. One more interesting thing I found, I see errors start appearing at 4:52AM last until 6am and again start at 16:52am on same day.. I... (5 Replies)
Discussion started by: upengan78
5 Replies

6. AIX

SCSI PCI - X RAID Controller card RAID 5 AIX Disks disappeared

Hello, I have a scsi pci x raid controller card on which I had created a disk array of 3 disks when I type lspv ; I used to see 3 physical disks ( two local disks and one raid 5 disk ) suddenly the raid 5 disk array disappeared ; so the hardware engineer thought the problem was with SCSI... (0 Replies)
Discussion started by: filosophizer
0 Replies

7. Solaris

Firmware password Solaris Sun Fire v440

Hi: I bougth an used Sun Fire v440, and It have a firmware password. When I turn on the server, it ask for firmware password. (I don 't know what is the correct password). I can access to SC, but when I want to access to OBP, Firmware Password appears again. I remove the battery for two hours,... (1 Reply)
Discussion started by: mguazzardo
1 Replies

8. Solaris

Sun Fire v440 Over heat Problem.

Dear Team, I need some expert advice to my problem. We have a Sun Fire v440 in our customer Place. Server is working fine and no hardware deviations are found except one problem that processors generating too much heat. I have verified and found that the room temperature was 26-27 degree.... (5 Replies)
Discussion started by: sudhansu
5 Replies

9. Solaris

Sun-Fire V440 boot disk issue

Hi, I have Sun Fire V440. Boot disks are mirrored. system crashed and it's not coming up. Error message is Insufficient metadevice database replicas located. Use Metadb to delete databases which are broken. Boot disks are mirrored and other disks are ZFS configuration. Please... (2 Replies)
Discussion started by: samnyc
2 Replies

10. Solaris

Removing a disk from SUN Fire V440 running Solaris 8

Hi, I have a SUN Fire V440 server running Solaris 8. One of the 4 disks do not appear when issued the format command. The "ready to remove" LED is not on either. Metastat command warns that this disk "Needs maintenace". Can I just shutdown and power off the machine and then insert an... (5 Replies)
Discussion started by: Echo68
5 Replies
vgmove(1M)																vgmove(1M)

NAME
vgmove - move data from an old set of disks in a volume group to a new set of disks SYNOPSIS
autobackup] diskmapfile vg_name autobackup] diskfile diskmapfile vg_name DESCRIPTION
The command migrates data from the existing set of disks in a volume group to a new set of disks. After the command completes successfully, the new set of disks will belong to the same volume group. The command is intended to migrate data on a volume group from old storage to new storage. The diskmapfile specifies the list of source disks to move data from, and the list of destination disks to move data to. The user may choose to list only a subset of the existing physical volumes in the volume group that need to be migrated to a new set of disks. The format of the diskmapfile file is shown below: source_pv_1 destination_pv_1_1 destination_pv_1_2 .... source_pv_2 destination_pv_2_1 destination_pv_2_2 .... .... source_pv_n destination_pv_n_1 destination_pv_n_2 .... If a destination disk is not already part of the volume group, it will be added using see vgextend(1M). Upon successful completion of the source disk will be automatically removed from the volume group using see vgreduce(1M). After successful migration, the destination disks are added to the LVM configuration files; namely, or The source disks along with their alternate links are removed from the LVM configuration files. A sample diskmapfile is shown below: /dev/disk/disk1 /dev/disk/disk51 /dev/disk/disk52 /dev/disk/disk2 /dev/disk/disk51 /dev/disk/disk3 /dev/disk/disk53 The diskmapfile can be manually created, or it can be automatically generated using the diskfile and diskmapfile options. The argument diskfile contains a list of destination disks, one per line such as the sample file below: /dev/disk/disk51 /dev/disk/disk52 /dev/disk/disk53 When the option is given, reads a list of destination disks from diskfile, generates the source to destination mapping, and saves it to diskmapfile. The volume group must be activated before running the command. If the command is interrupted before it completes, the volume group is in the same state it was at the beginning of the command. The migration can be continued by running the command with the same options and disk mapping file. Options and Arguments The command recognizes the following options and arguments: vg_name The path name of the volume group. Set automatic backup for this invocation of autobackup can have one of the following values: Automatically back up configuration changes made to the volume group. This is the default. After this command executes, the command is executed for the volume group; see vgcfgbackup(1M). Do not back up configuration changes this time. Specify the name of the file containing the source to destination disk mapping. If the option is also given, will generate the disk mapping and save it to this filename. (Note that if the diskmapfile already exists, the file will be overwritten). Otherwise, will perform the data migration using this diskmapfile. Specify the name of the file containing the list of destination disks. This option is used with the option to generate the diskmapfile. When the option is used, no volume group data is moved. Preview the actions to be taken but do not move any volume group data. Shared Volume Group Considerations For volume group version 1.0 and 2.0, cannot be used if the volume group is activated in shared mode. For volume groups version 2.1 (or higher), can be performed when activated in either shared, exclusive, or standalone mode. Note that the daemon must be running on all the nodes sharing a volume group activated in shared mode. See lvmpud(1M). When a node wants to share the volume group, the user must first execute a if physical volumes were moved in or out of the volume group at the time the volume group was not activated on that node. LVM shared mode is currently only available in Serviceguard clusters. EXTERNAL INFLUENCES
Environment Variables determines the language in which messages are displayed. If is not specified or is null, it defaults to "C" (see lang(5)). If any internationalization variable contains an invalid setting, all internationalization variables default to "C" (see environ(5)). EXAMPLES
Move data in volume group from to After the migration, remove from the volume group: Generate a source to destination disk map file for where the destination disks are and SEE ALSO
lvmpud(1M), pvmove(1M), vgcfgbackup(1M), vgcfgrestore(1M), vgextend(1M), vgreduce(1M), intro(7), lvm(7). vgmove(1M)
All times are GMT -4. The time now is 02:49 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy