Sponsored Content
Full Discussion: Power machine 720 SAS disk
Operating Systems AIX Power machine 720 SAS disk Post 303042758 by Phat on Monday 6th of January 2020 04:40:03 AM
Old 01-06-2020
Power machine 720 SAS disk

Hello,

I would like to check how many SAS disks and its size per disk for the whole power system. As per my understanding, if we assign the SAS controller to LPAR, then we can see the disk in lpar smitty command.

How can we check from the Power machine(physical ones) as well? I think the power system should know how many disks it has and its size.

I have check in ASMI page, and in the console SMS, I can see some disks, but not see the size (screenshot attached).

Power machine 720 SAS disk-sas_diskpng
 

10 More Discussions You Might Find Interesting

1. UNIX for Advanced & Expert Users

mount disk on other machine

I have two Unix machines on the network and now one of them are running out of disk but i have alot on the other so i like to mount the disk (or a folder) from the one that has disk and mount it on the other that does not. How do i do that? Is it possible i read the "man mount" but didn't really... (5 Replies)
Discussion started by: sajjan2
5 Replies

2. UNIX for Dummies Questions & Answers

command to know disk controllers in a machine

Hi!! I am these days working on a project, where I need to know about the disk controllers available in a machine (e.g., 3ware,IBM,etc). Please, let me know the command by which I can get the information. thnx, priyanka (3 Replies)
Discussion started by: reply2priyanka
3 Replies

3. AIX

Maximum Limit of HMC to handle Physical Power Virtualization Physical Machine

Hello All, Can anybody please tell me what is the maximum limit of Physical IBM Power Machine which can be handled by single HMC at a single point of time? Thanks, Jenish (1 Reply)
Discussion started by: jenish_shah
1 Replies

4. AIX

POWER HA 5.5 & Service IP / disk heart beat

Hello, I have a quick question regarding POWER HA ( HACMP ) 5.5 ; I have four ethernet adapters en0 en1 en2 en3 en0 is configured as BOOT_IP with IP address all other ethernet adapters are empty en1 / en2 / en3 so when I configure the service IP and start HACMP , the service IP... (2 Replies)
Discussion started by: filosophizer
2 Replies

5. UNIX for Dummies Questions & Answers

find physical disk type : SAS / SATA

Hi, Is there an easy way to find the disk-type from the command line or with another api ? sdparm works for SAS but not for SATA, hdparm works for SATA but not SAS. Thanks (1 Reply)
Discussion started by: coderd
1 Replies

6. AIX

Power HA 7 repository disk unmirrored?

hi guys, I don't like the new concept of the power ha 7 cluster with the repository disk and the internal solidb, I really would like to mirror this disk, but the "IBM PowerHA SystemMirror 7.1 for AIX" redbook says, normal lvm operations should not be performed on this disk. even mirroring the... (0 Replies)
Discussion started by: funksen
0 Replies

7. UNIX for Dummies Questions & Answers

How to get current power consumption of a machine

Hi Is there any native commands or somewhere in the /proc files to get the machine's power consumption? I googled for a while and cannot really find this information Thanks for your help. (6 Replies)
Discussion started by: flagman5
6 Replies

8. Red Hat

Udev Rule TAG for identifying a local sas disk, non-scsi, non-fiber, non-iscsi

I need to add a VMware virtual disk to the 99-oracle-asmdevices.rules file but the OS is not assigning a WWID to the disk. It has been fdisk'd and a single partition created. What TAG inside the file needs to be added? the Program scsi-id does not work for some reason. latest patches... (0 Replies)
Discussion started by: mrmurdock
0 Replies

9. AIX

Power Machine password

Hi, I have installed the HMC on the VMWare VM. I try to add the power machine (managed system) and asking for a password? So this is the IBM predefined password of Power Machine? In the VMWare perspective, we can login to ESX host to do some management tasks. But how about the Power machine?... (6 Replies)
Discussion started by: Phat
6 Replies

10. AIX

Replaced pdisk not showing up in SAS Disk Array Configuration

OSLevel: 5300-10-02-0943 System Model: IBM,8203-E4A Power 6 == Hi! I replaced a failed pdisk in the raid enclosure as follows, - rmdev -l 'pdisk18' '-d' - Replaced it. - cfgmgr (detected) - I can see the new drive, with the correct serial # lscfg -v -l pdisk18 pdisk18... (2 Replies)
Discussion started by: estrar
2 Replies
vgchgid(1M)															       vgchgid(1M)

NAME
vgchgid - modify the Volume Group ID (VGID) on a given set of physical devices SYNOPSIS
PhysicalVolumePath [PhysicalVolumePath] ... DESCRIPTION
The command is designed to change the LVM Volume Group ID (VGID) on a supplied set of disks. will work with any type of storage, but it is primarily targeted at disk arrays that are able to create "snapshots" or "clones" of mirrored LUNs. accepts a set of raw physical devices and ensures that they all belong to the same volume group, before altering the VGID (see section). The same VGID is set on all the disks and it should be noted that in cases of multi-PV volume groups, all the physical volumes should be supplied in a single invocation of the command. Options recognizes the following options and arguments: PhysicalVolumePath The raw devices path name of a physical volume. Background Some storage subsystems have a feature which allows a user to split off a set of mirror copies of physical storage (termed or just as LVM splits off logical volumes with the command. As the result of the "split," the split-off devices will have the same VGID as the original disks. is needed to modify the VGID on the BCV devices. Once the VGID has been altered, the BCV disks can be imported into a new volume group by using WARNINGS
Once the VGID has been changed, the original VGID is lost until a disk device is re-mirrored with the original devices. If is used on a subset of disk devices (for example, two out of four disk devices), the two groups of disk devices would not be able to be imported into the same volume group since they have different VGIDs on them. The solution is to re-mirror all four of the disk devices and re-run on all four BCV devices at the same time, and then use to import them into the same new volume group. If a disk is newly added to an existing volume group and no subsequent LVM operations has been performed to alter the structures (in other words, operations which perform an automated vgcfgbackup(1M)); then it is possible a subsequent will fail. It will report that the disk does not belong to the volume group. This may be overcome by performing a structure changing operation on the volume group (for example, using It is the system administrator's responsibility to make sure that the devices provided in the command line are all Business Copy volumes of the existing standard physical volumes and are in the ready state and writable. Mixing the standard and BC volumes in the same volume group can cause data corruption. RETURN VALUE
returns the following values: 0 VGID was modified with no error 1 VGID was not modified EXAMPLES
An example showing how might be used: 1. The system administrator uses the following commands to create the Business Continuity (BCV or BC) copy: 1) For EMC Symmetrix disks, the commands are and 2) For XP disk array, the commands are and Three BCV disks are created. 2. Change the VGID on the BCV disks. 3. Make a new volume group using the BCV disks. This step can be skipped as the group file will be created automatically. If the file is manually created it will have different major and minor numbers (see lvm(7)). 4. Import the BCV disks into the new volume group. 5. Activate the new volume group. 6. Backup the new volume group's LVM data structure. 7. Mount the associated logical volumes. SEE ALSO
vgimport(1M), vgscan(1M), vgcfgbackup(1M). vgchgid(1M)
All times are GMT -4. The time now is 01:50 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.