Sponsored Content
Operating Systems AIX AIX LPAR FC connection to SAN Post 303031503 by bakunin on Friday 1st of March 2019 11:28:21 AM
Old 03-01-2019
Quote:
Originally Posted by Phat
In the HMC profile, I can see there are 3 physical FC assigned to the server as attached.

I also see 6 FC ports which is equivalent from 3x2=6
Exactly. Look at the "location codes" which i have marked bold:

Code:
[root@zzz] / > lsdev -Cc adapter | grep fcs
fcs0 Available 00-00 8Gb PCI Express Dual Port FC Adapter (df1000f114108a03)
fcs1 Available 00-01 8Gb PCI Express Dual Port FC Adapter (df1000f114108a03)
fcs2 Available 01-00 8Gb PCI Express Dual Port FC Adapter (df1000f114108a03)
fcs3 Available 01-01 8Gb PCI Express Dual Port FC Adapter (df1000f114108a03)
fcs4 Available 05-00 8Gb PCI Express Dual Port FC Adapter (df1000f114108a03)
fcs5 Available 05-01 8Gb PCI Express Dual Port FC Adapter (df1000f114108a03)

fcs0 and fcs1 are port 0 and 1 from the same adapter, etc. for the others. In the HMC display you posted you see the "real" (physical) location codes where the adapters are located in the system. I.e. one adapter is located in the CEC with serial number 9K83854 in slot P1-C5.

Quote:
Originally Posted by Phat
Can we say the "physical" FC adapter here are actually the real physical FC adapter from Power Machine which are assigned to the lpar not via VIOS (with virtual FC adapter) ?
Yes, absolutely. The reason for the VIOS is this: you have some "anonymous" resources like memory and CPUs which you can easily transfer between LPARs. You cannot do this with adapters, obviously, because they are connected to something and they are configured on the "outside" too. Neither you can do that with disks because they contain data which makes them the opposite of "anonymous". Therefore there is the VIOS, which takes all the physical ressources, creates virtual constructs representing these and then gives these constructs to the LPAR. This way you can move an LPAR from on managed system to the other because VIOSes ahve special means to transfer the physical layer between one another and for the LPAR the virtual construct it uses never changes - just the way it is representing some physical ressource.

I hope this helps.

bakunin
 

10 More Discussions You Might Find Interesting

1. AIX

p6 570 network for AIX LPAR

know how to do it. (3 Replies)
Discussion started by: rainbow_bean
3 Replies

2. AIX

VIO SAN STORAGE LPAR ( Dynamically increasing size )

Hi, Is there a way to dynamically increase the size of virtual disk on the LPAR. The virtual disk is coming from my VIO Server. From my SAN I have allocated a disk to VIO Server and from VIO Server to my LPAR....If I increase the space of the logical SAN DISK (DS 4700 using IBM TotalStorage... (0 Replies)
Discussion started by: filosophizer
0 Replies

3. AIX

How to Find if AIX machine is LPar or not

Hi, I want to know if there is any command which will tell me if an AIX machine is a LPar or not. I am using "lparstat -i" but it does not work on all AIX machines. Is there any generic command by whose output I will come to know if it is an LPar or not? Please help. Thanks, Vineet (3 Replies)
Discussion started by: vineetd
3 Replies

4. AIX

p595 LPAR no longer sees SAN boot disk

Hello, we have a wierd and urgent problem, with a few of our p595 LPARs running AIX 5.3. The LPARs ran AIX 5.3 TL 7 and booted off EMC SAN disks, using EMC Powerpath. Every boot we run "pprootdev on" and "pprootdev fix". We can issue "bosboot -a" and we can reboot the machines. Now, on two... (2 Replies)
Discussion started by: rwesterik
2 Replies

5. Solaris

SAN connection - configuring fibre attached hard drive

Hi All, I recently got a connection to the SAN through a fibre channel on my solaris box: #luxadm -e port /devices/pci@1d,700000/SUNW,qlc@1/fp@0,0:devctl CONNECTED #ls -l /dev/cfg lrwxrwxrwx 1 root root 48 Feb 23 12:31 c4 -> ../../devices/pci@1d,700000/SUNW,qlc@1/fp@0,0:fc I then... (2 Replies)
Discussion started by: dede
2 Replies

6. AIX

AIX admin - lpar question

Hi Guru, my question is that can I create LPAR in AIX 5.3, 6.0, 6.1 by using smit lpar, rather than using HMC or AIX Commands? Thank you very much. Mir Alihttp://xwww.unix.com/images/icons/icon5.gif (3 Replies)
Discussion started by: Tahniet
3 Replies

7. AIX

How to check the LPAR in a AIX box ?

I have login into a server, and when i launch this command uname -L. I can see there is a LPAR. But is there anymore commands i can use to get more information on the LPAR ? like it is VIO ? wat the IP address ? etc, etc. please help. Thank you. (7 Replies)
Discussion started by: wingcross
7 Replies

8. AIX

AIX 5.2.0 on own hardware -> i550 LPAR

We are running into a problem that we thought had solved but no go... We have multiple machine types but 1 AIX and 2 i550 (AS/400) with 4 lpar each. Existing AIX is an old (2004 vintage) machine with 5.2 on it for historical use only. Existing Power6 i550 running code that will used... (6 Replies)
Discussion started by: jackb_guppy
6 Replies

9. AIX

Will it affect my AIX LPAR security, when i set up email alerts on AIX server.

Hello, I've set up email alerts on AIX Servers. so that i can get email notifications (via mail relay server) when ever there is abnormal behavior. for example 1) my script monitors CPU/disk/memory etc... when it reaches high water ark, it will send an email alert. 2) disk usage alerts 3)... (5 Replies)
Discussion started by: System Admin 77
5 Replies

10. UNIX for Beginners Questions & Answers

AIX - SAN Mount and Unmount on LPAR

We have 2 LPAR. LPAR #1 have a Application, Database Server process (ctree Server) and SAN+Physical Table. LPAR#2 has only Application. Both Application process are connected to Database via C-tree Server Process (Running on LPAR #1.. We want to keep one Active C-tree Server and one Backup... (1 Reply)
Discussion started by: gabhanes
1 Replies
fence_vixel(8)						      System Manager's Manual						    fence_vixel(8)

NAME
fence_vixel - I/O Fencing agent for Vixel FC switches SYNOPSIS
fence_vixel [OPTION]... DESCRIPTION
fence_vixel is an I/O Fencing agent which can be used with Vixel FC switches. It logs into a Vixel switch via telnet and removes the spec- ified port from the zone. Removing the zone access from the port disables the port from being able to access the storage. fence_vixel accepts options on the command line as well as from stdin. fenced sends parameters through stdin when it execs the agent. fence_vixel can be run by itself with command line options which is useful for testing. After a fence operation has taken place the fenced machine can no longer connect to the Vixel FC switch. When the fenced machine is ready to be brought back into the GFS cluster (after reboot) the port on the Vixel FC switch needs to be enabled. In order to do this, log into the Vixel FC switch. Then go to: config->zones->config <port> <comma-separated-list-of-ports-in-the-zone> Then apply Consult the Vixel manual for details Vendor URL: http://www.emulex.com OPTIONS
-a IPaddress IP address of the switch. -h Print out a help message describing available options, then exit. -n port The port number to remove zoning from on the switch. -p password Password for login. -S path Full path to an executable to generate the password for login. -V Print out a version message, then exit. STDIN PARAMETERS
agent = < param > This option is used by fence_node(8) and is ignored by fence_vixel. ipaddr = < hostname | ip > IP address or hostname of the switch. passwd = < param > Password for login. passwd_script = < param > Full path to an executable to generate the password for login. port = < param > The port number to remove zoning from on the switch. SEE ALSO
fence(8), fence_node(8) fence_vixel(8)
All times are GMT -4. The time now is 07:06 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy