Sponsored Content
Operating Systems AIX AIX LPAR FC connection to SAN Post 303031477 by Phat on Friday 1st of March 2019 05:56:41 AM
Old 03-01-2019
In the HMC profile, I can see there are 3 physical FC assigned to the server as attached.

I also see 6 FC ports which is equivalent from 3x2=6

Code:
[root@zzz] / > lsdev -Cc adapter | grep fcs
fcs0 Available 00-00 8Gb PCI Express Dual Port FC Adapter (df1000f114108a03)
fcs1 Available 00-01 8Gb PCI Express Dual Port FC Adapter (df1000f114108a03)
fcs2 Available 01-00 8Gb PCI Express Dual Port FC Adapter (df1000f114108a03)
fcs3 Available 01-01 8Gb PCI Express Dual Port FC Adapter (df1000f114108a03)
fcs4 Available 05-00 8Gb PCI Express Dual Port FC Adapter (df1000f114108a03)
fcs5 Available 05-01 8Gb PCI Express Dual Port FC Adapter (df1000f114108a03)

Can we say the "physical" FC adapter here are actually the real physical FC adapter from Power Machine which are assigned to the lpar not via VIOS (with virtual FC adapter) ?
AIX LPAR FC connection to SAN-aix_fcpng
 

10 More Discussions You Might Find Interesting

1. AIX

p6 570 network for AIX LPAR

know how to do it. (3 Replies)
Discussion started by: rainbow_bean
3 Replies

2. AIX

VIO SAN STORAGE LPAR ( Dynamically increasing size )

Hi, Is there a way to dynamically increase the size of virtual disk on the LPAR. The virtual disk is coming from my VIO Server. From my SAN I have allocated a disk to VIO Server and from VIO Server to my LPAR....If I increase the space of the logical SAN DISK (DS 4700 using IBM TotalStorage... (0 Replies)
Discussion started by: filosophizer
0 Replies

3. AIX

How to Find if AIX machine is LPar or not

Hi, I want to know if there is any command which will tell me if an AIX machine is a LPar or not. I am using "lparstat -i" but it does not work on all AIX machines. Is there any generic command by whose output I will come to know if it is an LPar or not? Please help. Thanks, Vineet (3 Replies)
Discussion started by: vineetd
3 Replies

4. AIX

p595 LPAR no longer sees SAN boot disk

Hello, we have a wierd and urgent problem, with a few of our p595 LPARs running AIX 5.3. The LPARs ran AIX 5.3 TL 7 and booted off EMC SAN disks, using EMC Powerpath. Every boot we run "pprootdev on" and "pprootdev fix". We can issue "bosboot -a" and we can reboot the machines. Now, on two... (2 Replies)
Discussion started by: rwesterik
2 Replies

5. Solaris

SAN connection - configuring fibre attached hard drive

Hi All, I recently got a connection to the SAN through a fibre channel on my solaris box: #luxadm -e port /devices/pci@1d,700000/SUNW,qlc@1/fp@0,0:devctl CONNECTED #ls -l /dev/cfg lrwxrwxrwx 1 root root 48 Feb 23 12:31 c4 -> ../../devices/pci@1d,700000/SUNW,qlc@1/fp@0,0:fc I then... (2 Replies)
Discussion started by: dede
2 Replies

6. AIX

AIX admin - lpar question

Hi Guru, my question is that can I create LPAR in AIX 5.3, 6.0, 6.1 by using smit lpar, rather than using HMC or AIX Commands? Thank you very much. Mir Alihttp://xwww.unix.com/images/icons/icon5.gif (3 Replies)
Discussion started by: Tahniet
3 Replies

7. AIX

How to check the LPAR in a AIX box ?

I have login into a server, and when i launch this command uname -L. I can see there is a LPAR. But is there anymore commands i can use to get more information on the LPAR ? like it is VIO ? wat the IP address ? etc, etc. please help. Thank you. (7 Replies)
Discussion started by: wingcross
7 Replies

8. AIX

AIX 5.2.0 on own hardware -> i550 LPAR

We are running into a problem that we thought had solved but no go... We have multiple machine types but 1 AIX and 2 i550 (AS/400) with 4 lpar each. Existing AIX is an old (2004 vintage) machine with 5.2 on it for historical use only. Existing Power6 i550 running code that will used... (6 Replies)
Discussion started by: jackb_guppy
6 Replies

9. AIX

Will it affect my AIX LPAR security, when i set up email alerts on AIX server.

Hello, I've set up email alerts on AIX Servers. so that i can get email notifications (via mail relay server) when ever there is abnormal behavior. for example 1) my script monitors CPU/disk/memory etc... when it reaches high water ark, it will send an email alert. 2) disk usage alerts 3)... (5 Replies)
Discussion started by: System Admin 77
5 Replies

10. UNIX for Beginners Questions & Answers

AIX - SAN Mount and Unmount on LPAR

We have 2 LPAR. LPAR #1 have a Application, Database Server process (ctree Server) and SAN+Physical Table. LPAR#2 has only Application. Both Application process are connected to Database via C-tree Server Process (Running on LPAR #1.. We want to keep one Active C-tree Server and one Backup... (1 Reply)
Discussion started by: gabhanes
1 Replies
st_san_safe(5)							     OBSOLETED							    st_san_safe(5)

NAME
st_san_safe - determine whether access to tape device special files without the no-rewind-on-close option is allowed (OBSOLETED) VALUES
Failsafe Default Allowed values Recommended values or DESCRIPTION
Note: this tunable is obsoleted and has been renamed to beginning with release HP-UX 11i v3. This tunable notifies the tape driver whether it should allow access to device special files without the no-rewind-on-close option. When this tunable is on the tape driver will fail any open on a tape device special file without the no-rewind-on-close option (that is, or with a status of The tunable allows the safe sharing of tape devices in SAN tape backup solution configurations. The disabling of device special files without no-rewind-on-close in a SAN tape backup solution configuration prevents the accidental sending of a rewind command on close from HP-UX systems via standard tape commands like which would corrupt a backup in process. Who Is Expected to Change This Tunable? Anyone. Restrictions on Changing Changes to this tunable take effect immediately. When Should the Tunable Be Turned On? This tunable should be turned on if the system is going to be used in a SAN tape backup solution configuration. What Are the Side Effects of Turning the Tunable On? The tape driver will fail any open to a tape device special file that does not have the no-rewind-on-close option with a status of This behavior prevents the usage of any tape device special file without the no-rewind-on-close option. When Should the Tunable Be Turned Off? This tunable should be turned off if the system is not part of a SAN tape backup solution configuration or the system utilizes will not function unless it has access to device special files without the no-rewind-on-close option. What Are the Side Effects of Turning the Tunable Off? A rewind may be issued from this system accidentally on close possibly corrupting a backup being issued from another system on the SAN. What Other Tunables Should Be Changed at the Same Time? None. WARNINGS
All HP-UX kernel tunable parameters are release specific. This parameter may be removed or have its meaning changed in future releases of HP-UX. Installation of optional kernel software, from HP or other vendors, may cause changes to tunable parameter values. After installation, some tunable parameters may no longer be at the default or recommended values. For information about the effects of installation on tun- able values, consult the documentation for the kernel software being installed. For information about optional kernel software that was factory installed on your system, see at AUTHOR
was developed by Hewlett-Packard. SEE ALSO
norewind_close_disabled(5), scsi_tape(7), scsimgr_estape(7). Tunable Kernel Parameters st_san_safe(5)
All times are GMT -4. The time now is 10:22 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy