The Lounge What is on Your Mind? Cut Over to New Data Center and Upgraded OS Done. :) Post 303022892 by Aia on Sunday 9th of September 2018 01:24:18 AM
Old 09-09-2018
I would like to repeat that it is all about CI/CD ( I do not have to highlight it since I made myself clear before). Companies (customers) that do not implement CI/CD for the most part do not appreciate the evolution to the Cloud. Thanks to Cloud computing and the implementation of automation the speed of developing and delivering time for applications is faster. I enjoy engineering systems that almost do not require manual intervention from the moment that we commit code to source control.
I have enjoyed seeing teams confidence raise by the nature of CI, knowing that tests are well crafted, and real to what it will show in production. That a whole piece of infrastructure is created at demand, automatically for CI and once that the fast feedback is reported, it is brought down until the next test, which it could be some few minutes later. This is not a buzzword, it is real results that benefits organizations that wants faster deployments without compromising quality assurance and I have the fortune to work doing that. There is pride in me when I know I have engineered a system that provides reproducible results and that has been committed to source control and that can be brought to life in several minutes.
In fact, with the utilization of containers now I can even provide quicker infrastructure where immutability is possible.
It is not my intention to convince anyone (I am not in that business) but I want to reintegrate my original statement.

Last edited by Aia; 09-09-2018 at 03:20 AM..
This User Gave Thanks to Aia For This Post:
 

5 More Discussions You Might Find Interesting

1. Virtualization and Cloud Computing

Cloud Enabling Computing for the Next Generation Data Center

Hear how the changing needs of massive scale-out computing is driving a transfomation in technology and learn how HP is supporting this new evolution of the web. More... (1 Reply)
Discussion started by: Linux Bot
1 Replies

2. HP-UX

Need to set up a HP cluster system in a data center

What are the server requirements, Software requirements, Network requirements etc, Please help me.. as 'm new 'm unable to get things done @ my end alone. Please refrain from typing subjects completely in upper case letters to get more attention, ty. (5 Replies)
Discussion started by: Sounddappan
5 Replies

3. Shell Programming and Scripting

Failure rate of a node / Data center

Hi, Please, i have a history of the state of each node in my data center. an history about the failure of my cluster (UN: node up, DN: node down). Here is some lines of the history: 08:51:36 UN 127.0.0.1 08:51:36 UN 127.0.0.2 08:51:36 UN 127.0.0.3 08:53:50 DN 127.0.0.1 ... (6 Replies)
Discussion started by: chercheur111
6 Replies

4. What is on Your Mind?

Resolved: Issue in Server Data Center

Dear All, There was a problem in the data center data, which caused the server to be unreachable for about an hour. Server logs show the server did not crash or go down. Hence, I assume there was a networking issue at the data center. Still waiting for final word on what happened. ... (4 Replies)
Discussion started by: Neo
4 Replies

5. What is on Your Mind?

OUTAGE: Data Center Problem Resolved.

There was a problem with our data center today, creating a site outage (server unreachable). That problem has been resolved. Basically, it seems to have been a socially engineered denial-of-service attack against UNIX.com; which I stopped as soon as I found out what the problem was. Total... (2 Replies)
Discussion started by: Neo
2 Replies
shutdown(8)						      System Manager's Manual						       shutdown(8)

NAME
shutdown - bring the system down SYNOPSIS
shutdown [OPTION]... TIME [MESSAGE] DESCRIPTION
shutdown arranges for the system to be brought down in a safe way. All logged-in users are notified that the system is going down and, within the last five minutes of TIME, new logins are prevented. TIME may have different formats, the most common is simply the word 'now' which will bring the system down immediately. Other valid for- mats are +m, where m is the number of minutes to wait until shutting down and hh:mm which specifies the time on the 24hr clock. Once TIME has elapsed, shutdown sends a request to the init(8) daemon to bring the system down into the appropriate runlevel. This is performed by emitting the runlevel(7) event, which includes the new runlevel in the RUNLEVEL environment variable as well as the previous runlevel (obtained from the environment or from /var/run/utmp) in the PREVLEVEL variable. An additional INIT_HALT variable may be set, this will contain the value HALT when bringing the system down for halt and POWEROFF when bringing the system down for power off. OPTIONS
-r Requests that the system be rebooted after it has been brought down. -h Requests that the system be either halted or powered off after it has been brought down, with the choice as to which left up to the system. -H Requests that the system be halted after it has been brought down. -P Requests that the system be powered off after it has been brought down. -c Cancels a running shutdown. TIME is not specified with this option, the first argument is MESSAGE. -k Only send out the warning messages and disable logins, do not actually bring the system down. ENVIRONMENT
RUNLEVEL shutdown will read the current runlevel from this environment variable if set in preference to reading from /var/run/utmp FILES
/var/run/utmp Where the current runlevel will be read from; this file will also be updated with the new runlevel. /var/log/wtmp A new runlevel record will be appended to this file for the new runlevel. NOTES
The Upstart init(8) daemon does not keep track of runlevels itself, instead they are implemented entirely by its userspace tools. See runlevel(7) for more details. AUTHOR
Written by Scott James Remnant <scott@netsplit.com> REPORTING BUGS
Report bugs at <https://launchpad.net/upstart/+bugs> COPYRIGHT
Copyright (C) 2009 Canonical Ltd. This is free software; see the source for copying conditions. There is NO warranty; not even for MERCHANTABILITY or FITNESS FOR A PARTICU- LAR PURPOSE. SEE ALSO
runlevel(7) init(8) telinit(8) reboot(8) Upstart 2009-07-09 shutdown(8)
All times are GMT -4. The time now is 10:58 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy