06-19-2018
no support since its older. just a company that swaps parts. I did try the power on each domain and same result , did no reset fault, what command does that? I will try and find it.
9 More Discussions You Might Find Interesting
1. AIX
Hello:
NOOB here. I attempted to use smit mkcd. Failed on first attempt, not enough space. 2nd attempt tried to place iso on /usr, not enough space there. Cleanup ran for about 5 minutes after aborting. Now AIX won't boot. LCD display on 7029-6E3 says: 0517 MOUNT /USR. Attempted to boot from CD... (11 Replies)
Discussion started by: bbird
11 Replies
2. Solaris
Hi,
I 've a fully loaded M5000 which i would like to partition in 4 domains but i have a concern that since we have only 4 internal disks how can we partition the box in for domains with 2 disks ( mirrored ) in each domain. Should i go ahead with 1 Lun from SAN and 1 internal disk for each of 4... (3 Replies)
Discussion started by: fugitive
3 Replies
3. Solaris
Hi i 've a M5000 running 2 domains in my Lab with following hardconf
SPARC Enterprise M5000; Memory_Size:128 GB;
+-----------------------------------+------------+
| FRU | Quantity |
+-----------------------------------+------------+
| MBU_B... (3 Replies)
Discussion started by: fugitive
3 Replies
4. Solaris
Please advise. Thank you
bash-3.00# cd /usr/sunvts/bin/
bash-3.00# ls
bios.bin iobushangscript.sh stopsunvts vtsprobe
cmos.bin javabridge.jar sunlink vtsreportgenerate
dispatcher loadVtsServer svmVolDiskList vtstalk
env6test... (6 Replies)
Discussion started by: incredible
6 Replies
5. Hardware
I have an M5K with disk issues I'm trying to troubleshoot, and it's causing me some confusion. I know the host has four on-board HDDs, but the format command's output shows c0t0d0, c0t1d0, c3t0d0, and c3t1d0. cfgadm -al shows c0t3d0 as the DVD-ROM drive, and c1 and c2 as SAN disks. Confused yet?
... (2 Replies)
Discussion started by: desertdenizen
2 Replies
6. IP Networking
I took over an M5000 and have a jumper server with a nic to connect to the console IP of an M5000. access via ssh user@ip.
it was working fine, another person can connect remotely on the subnet, but when I ssh,it just hangs and then times out.
so my question is,
any ideas of what I might... (4 Replies)
Discussion started by: rrodgers
4 Replies
7. Solaris
I have an m5000 that Is down.
I have access to XSCF>
and was able to get to the ok prompt.
However, on
>ok boot
it failed to boot.
erred with :
svc.startd: svc:/system/device/fc-fabric:default: Method "/lib/svc/method/fc-fabric" failed due to signal KILL.
Nov 29... (3 Replies)
Discussion started by: goya
3 Replies
8. AIX
A team member installed the wrong version of License Code on a Power 740 system used in our Development environment.
The system will no longer boot.
Does anyone have IBM documentation or experience to share on recovering a system that currently reports "Unsupported License Code version... (1 Reply)
Discussion started by: kevinedailey
1 Replies
9. UNIX for Beginners Questions & Answers
Can anyone offer any advice on how to modify the script below to work on a new system we have, that has no graphics capability? We admin the system through a serial RAS device. I've tried running the below script through the RAS and through an ssh -X session. It failed with something like "GTK... (3 Replies)
Discussion started by: yelirt5
3 Replies
uac(1) General Commands Manual uac(1)
NAME
uac - Unaligned Access Message Control
SYNOPSIS
uac p | s [value]
uac p | s [keyword]
OPTIONS
The following options are used with the uac command: Sets or displays the current option setting for the parent process Sets or displays
the current option setting for the system
The following keywords are used with the p option: Reset the current option settings to the default for the parent process Do not print the
unaligned access warning message for the parent process Do not fix the unaligned access for the parent process Deliver a SIGBUS signal to
the parent process
The following keywords are used with the s option: Reset the current option settings to the default for the system Do not print the
unaligned access warning message for the system
Usually, the parent process is the shell.
DESCRIPTION
Most complex instruction set computers (CISC) can access unaligned data but only at a significantly reduced speed. Most reduced instruc-
tion set computers (RISC) do not attempt to handle unaligned accesses. Instead, they generate an unaligned access trap and let the operat-
ing system handle the fault.
The default action for the operating system when an unaligned access fault occurs is to fix the unaligned access fault and then display a
warning message informing the user process that an unaligned access fault has occurred. The warning message has the following form:
"Unaligned access pid=nnn <prog_name> va=virtual_addr pc=pc_addr". If you want to change the code to prevent the unaligned access faults
from occurring in the future, the warning message gives you the information you need to locate the code causing a fault. (See the Program-
mer's Guide for details on the causes and effects of misaligned data.)
In addition, the default action for the operating system is to not deliver a SIGBUS signal to the parent process when an unaligned access
fault occurs.
These defaults are satisfactory for most users, but some users require a different behavior and want to specify their own Unaligned Access
Control (UAC).
The uac command enables or disables the display of "Unaligned access" messages. The command sets or displays the UAC_NOPRINT, UAC_NOFIX,
and UAC_SIGBUS options, as defined in setsysinfo(2).
If value is not specified, the current option setting is displayed. You can specify value as either 0 (zero) or 1 (one). If value is 0
(zero), the option is turned on and messages are not displayed. If value is 1 (one), the option is turned off and messages are displayed.
Keywords can be used singly, or in any combination. However, the reset keyword overrides any other keywords it is used with.
RESTRICTIONS
You must be superuser to set the system option.
EXAMPLES
Both of the following commands disable messages for the parent process: # uac p 0
# uac p noprint Both of the following commands enable messages for the system: # uac s 1
# uac s reset The following command disables fixing of an unaligned access fault, disables printing a message for an unaligned
access fault to the parent process, and enables delivery of a SIGBUS signal to the parent process: # uac p nofix noprint sigbus
SEE ALSO
getsysinfo(2), setsysinfo(2)
Programmer's Guide