nothing happened... seems like tar was not working,\
reinstalled tar and it failed
Code:
Command: failed stdout: yes stderr: no
Before command completion, additional instructions may appear below.
[MORE...3]
tar-1.22
Validating RPM package selections ...
Please wait...
+-----------------------------------------------------------------------------+
RPM Error Summary:
+-----------------------------------------------------------------------------+
The following errors occurred during installation:
package tar-1.22-1 is for a different operating system
and on another machine
Code:
root@test8:/>gunzip < /configapp/bkp_14JUN16_oraapp.tgz | /opt/freeware/bin/tar xvf -
/opt/freeware/bin/tar: This does not look like a tar archive
/opt/freeware/bin/tar: Skipping to next header
/opt/freeware/bin/tar: Archive contains obsolescent base-64 headers
Last edited by filosophizer; 06-15-2016 at 02:11 PM..
SunOS machinename 5.8 Generic_108528-13 sun4u sparc SUNW,Ultra-Enterprise-10000
I am gzipping a file over 2GB and get this error message:
Filename :Value too large for defined data type
Is this because the file is over 2GB? (1 Reply)
Hi all,
Can anyone tell me a little about the datatype FILE, which represents stream. What does its structure look like, and in which header file is it defined and so on...
Ex :
FILE *fp ;
fp = fopen("filename", "w") ; (6 Replies)
Hello,
I get this message : "Value too large to be stored in data type" when I try to open a 3Gb file.
Can someone helps me to resolve the problem.
Thank you very much (5 Replies)
hi fndz.
Can you please help me with the code if I call a stored procedure from my shell script and stored procedure returns a cursor,
cursor output should be saved to a file (3 Replies)
Hi all,
I have this problem in one of the SCO UNIXWare 7.1.4. We have an application which is working on hundreds of machines. When we try to install the same application on a new machine, the executable/binary gives the following error and exits...
"xxx startup failure: Value too large for... (1 Reply)
Hi All,
I have a requirement to move a large amount of data *approx 160 GB* from a windows formatted SAN to AIX.
The data is made up of several hundred thousand small files.
Does anyone have a recommendation for the best tool or best procedure for this?
Regards,
Neil (2 Replies)
Hi,
I am trying to fetch sysname and nodename using struct utsname. I have two HP-UX servers on with 10 characters and other with 13 characters host name. For the first one I am getting truncated 8 characters as output but for the second one i am getting "Value too large to be stored in data type"... (1 Reply)
Hi All,
On HP Unix, 11.23 can following be checked ,
Processes which were consuming more
1)CPU
2)Memory
3)page faults
For particular Time Frame say Yesterday 7 Am to 7.30 Am
and , Yesterday Evening 19.00 Pm to 19.30 Pm
Please specify how.
whether we need to enable, some... (6 Replies)
Greetings Experts,
As part of automating the sql generation, I have the source table name, target table name, join condition stored in a file join_conditions.txt which is a delimited file (I can edit the file if for any reason). The reason I needed to store is I have built SELECT list without... (5 Replies)