Sponsored Content
Operating Systems AIX AIX Hardware Migration w/ HACMP...Advice Needed Post 302971626 by uzair_rock on Friday 22nd of April 2016 03:58:13 PM
Old 04-22-2016
AIX Hardware Migration w/ HACMP...Advice Needed

Hello Everyone,

Hope you all are doing great!

As you can see by the title on top, we are in the process of migrating alot of our servers from Power5 (physical) to Power8 (Virtual). Now it's turn for servers with HACMP Cluster on it. Let me lay out the environment like:

OLD ENVIRONMENT:

The Primary and secondary nodes resides on a Power5 host. Both are physical servers. The rootvg is on internal disks and the data vg's are on SAN Attached storage. Both primary and secondary nodes are on AIX 7.1 TL3 SP4. For HACMP we have a Active-Passive configuration.

NEW ENVIRONMENT:

Everything is virtualized. We have a Dual VIO setup on the Power8s. The boot disk are coming through a Storage cluster on VIO (vSCSI) and Data disks from SAN (NPIV).
As part of the new environment we are also moving on to the new network i.e. different IP subnet. (old=172.XXX) (new=10.XXX)

The way we have been migrating our previous (non-HA/test/dev) servers is that we clone the mksysb on to the vscsi disk on the new lpar before the day of the cutover and configure the new network on the server. On the day of cutover we bring down apps/DB on the old server (p5) then umount FS, varyoff and export VGs and remove the SAN disks. The storage team unmaps the LUNs and maps them back on the NEW WWPNs on the Power8 (NPIV).

On the new server we configure and import the disks and VGs and mount all FS inclulding NFS. Make DNS changes with the new IP and bring down all apps and DBs.

Now once we bring HACMP into the picture things become a little more complicated, can some of the experts here give me sound advice on how can we make the process as smooth as possible as we are moving on to the new server hardware as well as new network.


Thanks in Advance!
 

10 More Discussions You Might Find Interesting

1. Linux

programming advice needed....

i'm a grad student taking a UNIX course and a networks course (i have a background in C++ and JAVA). i'm trying to combine the two classes. My questions stems from a networks programming homework assignment below: "Using the operating system and language of your choice, develop a program to... (5 Replies)
Discussion started by: trostycp
5 Replies

2. Solaris

Storage hardware - advice needed

I realise this is an odd request - but I need advice please.. I have two server - in different geographical locations.. The have 2 local 72gb disks which are mirrored. I need to get storage added to increase both to 300gb in total each and this needs to be mirrored in case of failure. The... (2 Replies)
Discussion started by: frustrated1
2 Replies

3. AIX

IY17981 fix required for aix 4.3.3 to aix 5L migration but not found

Hi, redbook documentation is telling that IY17981 fix is required for aix 4.3.3 to aix 5L migration. But there is no mention about that fix in any ML installation packages. - My system is ML11 : oslevel –r 4330-11 - But xlC.rte is on wrong version : lslpp -L xlC.rte xlC.rte ... (3 Replies)
Discussion started by: astjen
3 Replies

4. Linux

Scripting advice needed

Evening all, Im trying to get a script that will: Select the most 3 recent files in a specific directory Run a command on them (like chmod) Ask of you would like to continue Copy the files to another directory If a linux guru could help me out, it would be very much appreciated. Thanks... (2 Replies)
Discussion started by: Wiggins
2 Replies

5. Hardware

Hardware issue advice

Hi all, I've got an issue with my PC and was wondering what you thought might be the issue. The problem manifests it'self in two ways (at least I'm assuming it's related). 1. I turn the power on at the wall and press the on button, but nothing happens. I have to wait for several seconds to... (3 Replies)
Discussion started by: DougyC
3 Replies

6. Hardware

Hardware compatibility advice wanted.

If anyone here is successfully running Linux Mint and PC-BSD on two dedicated hard disk drives, (no emulator or partitioning stuff), using Phenom II or Athlon II CPU, I'd like to ask your help to pick hardware! (5 Replies)
Discussion started by: Varsel
5 Replies

7. Solaris

Hardware to software RAID migration

We have hardware RAID configured on our T6320 server and two LDOMs are running on this server. One of our disk got failed and replaced. After replacemnt the newly installed disk not detected by RAID controlled so Oracle suggested to upgrade the REM firmware. As this is the standalone production... (0 Replies)
Discussion started by: rock123
0 Replies

8. HP-UX

VPar hardware migration - ERRATA document

Hi guys, I'm moving some vPars from BL860c I2 and BL870c I2 using the DRD clone and relocation. In some case, as instance to upgrade to BL870c I2, the ERRATA document reports some additional driver to be added to the image made by the DRD and then recompile the kernel before the move to the... (0 Replies)
Discussion started by: cecco16
0 Replies

9. AIX

AIX - FC Switch migration, SAN Migration question!

I'm New to AIX / VIOS We're doing a FC switch cutover on an ibm device, connected via SAN. How do I tell if one path to my remote disk is lost? (aix lvm) How do I tell when my link is down on my HBA port? Appreciate your help, very much! (4 Replies)
Discussion started by: BG_JrAdmin
4 Replies

10. Shell Programming and Scripting

Need advice for project UNIX to Linux migration

I am working on UNIX AIX to Linux migration. Does anybody know the good site for doing this? Thanks for contribution (4 Replies)
Discussion started by: digioleg54
4 Replies
vgchgid(1M)															       vgchgid(1M)

NAME
vgchgid - modify the Volume Group ID (VGID) on a given set of physical devices SYNOPSIS
PhysicalVolumePath [PhysicalVolumePath] ... DESCRIPTION
The command is designed to change the LVM Volume Group ID (VGID) on a supplied set of disks. will work with any type of storage, but it is primarily targeted at disk arrays that are able to create "snapshots" or "clones" of mirrored LUNs. accepts a set of raw physical devices and ensures that they all belong to the same volume group, before altering the VGID (see section). The same VGID is set on all the disks and it should be noted that in cases of multi-PV volume groups, all the physical volumes should be supplied in a single invocation of the command. Options recognizes the following options and arguments: PhysicalVolumePath The raw devices path name of a physical volume. Background Some storage subsystems have a feature which allows a user to split off a set of mirror copies of physical storage (termed or just as LVM splits off logical volumes with the command. As the result of the "split," the split-off devices will have the same VGID as the original disks. is needed to modify the VGID on the BCV devices. Once the VGID has been altered, the BCV disks can be imported into a new volume group by using WARNINGS
Once the VGID has been changed, the original VGID is lost until a disk device is re-mirrored with the original devices. If is used on a subset of disk devices (for example, two out of four disk devices), the two groups of disk devices would not be able to be imported into the same volume group since they have different VGIDs on them. The solution is to re-mirror all four of the disk devices and re-run on all four BCV devices at the same time, and then use to import them into the same new volume group. If a disk is newly added to an existing volume group and no subsequent LVM operations has been performed to alter the structures (in other words, operations which perform an automated vgcfgbackup(1M)); then it is possible a subsequent will fail. It will report that the disk does not belong to the volume group. This may be overcome by performing a structure changing operation on the volume group (for example, using It is the system administrator's responsibility to make sure that the devices provided in the command line are all Business Copy volumes of the existing standard physical volumes and are in the ready state and writable. Mixing the standard and BC volumes in the same volume group can cause data corruption. RETURN VALUE
returns the following values: 0 VGID was modified with no error 1 VGID was not modified EXAMPLES
An example showing how might be used: 1. The system administrator uses the following commands to create the Business Continuity (BCV or BC) copy: 1) For EMC Symmetrix disks, the commands are and 2) For XP disk array, the commands are and Three BCV disks are created. 2. Change the VGID on the BCV disks. 3. Make a new volume group using the BCV disks. This step can be skipped as the group file will be created automatically. If the file is manually created it will have different major and minor numbers (see lvm(7)). 4. Import the BCV disks into the new volume group. 5. Activate the new volume group. 6. Backup the new volume group's LVM data structure. 7. Mount the associated logical volumes. SEE ALSO
vgimport(1M), vgscan(1M), vgcfgbackup(1M). vgchgid(1M)
All times are GMT -4. The time now is 01:52 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy