Special Forums Hardware SAS or SSD for Ubuntu 14.04 and data analysis Post 302966538 by bakunin on Saturday 13th of February 2016 06:28:44 AM
Old 02-13-2016
Not directly related but i had a longer workshop yesterday about our new storage system (EMC VMax 200k). EMC claims that they had intended the 300GB 15k-SAS drives for high-performance, but phase them out now because (quoting from memory) with the development of Flash-SSDs its just not worth it any more. They also claim that, because they use SLC-based hardware, they have even lower rates of disk-replacement, even in heavy-duty transactional storage systems, than with rotational disks, to which a much lower energy consumption of the SSDs compared to the 15k-SAS disks contributes. There is simply less heat involved and that shows when you pack some ~2500 disks into a rack.

You haven't said where you are going to place the workstation, but in case it is going to be somewhere near your desk: 15k-disks are awefully LOUD in addition to be premier heating devices while SSDs are completely silent.

I hope this helps.

bakunin
These 2 Users Gave Thanks to bakunin For This Post:
 

6 More Discussions You Might Find Interesting

1. UNIX and Linux Applications

help needed- data analysis-table-chart-2d plot software

Hi all, I posted the same message under 'Kaleidagraph like software for Ubuntu' thread. I guess there may not be many people familiar with Kaleidagraph. So I post my message under another subject name. I need a tool for Ubuntu 8.10, -which is quick and easy to learn and use (as I am... (1 Reply)
Discussion started by: apprentice
1 Replies

2. BSD

Using SSD in FreeBSD

Now that SSD drives are becoming mainstream, I had a few questions on installing a SSD drive in a FreeBSD environment. Can FreeBSD be made SSD aware, that is, somehow let FreeBSD know that reads and writes should be limited or deferred to extend the disk's life? Is there a setting for wear... (0 Replies)
Discussion started by: figaro
0 Replies

3. Red Hat

What is the best tools for performance data gathering and analysis?

Dear Guru, IHAC who complaint that his CentOS is getting performance issue. I have to help him out of there. Could you please tell me which tools is better to gathering the whole system performance data? -- CPU/Memory/IO(disk & Network)/swap I would like the tools could be... (6 Replies)
Discussion started by: devyfong
6 Replies

4. Shell Programming and Scripting

Help with analysis data based on particular column content

Input file: Total_counts 1306726155 100% Number_of_count_true 855020282 Number_of_count_true_1 160014283 Number_of_count_true_2 44002825 Number_of_count_true_3 18098424 Number_of_count_true_4 24693745 Number_of_count_false 115421870 Number_of_count_true 51048447 Total_number_of_false ... (2 Replies)
Discussion started by: perl_beginner
2 Replies

5. UNIX for Dummies Questions & Answers

Data analysis, Regular Expression - Unix

Hey every one! I have a dataset like this : 1 100 1 0 5 100 1 8 7 50 1 0 7 100 2 0 10 20 1 8 10 30 1 8 10 100 3 8 15 50 5 0 20 90 1 0 20 99 9 0 I wanna check if the 4th column is 0 or 8 If it's zero write the 1st column itself, if it's 8 write sum of 1st and second something... (2 Replies)
Discussion started by: @man
2 Replies

6. UNIX for Dummies Questions & Answers

What should I format my SSD with?

Hello All, I recently received a new SSD that I am going to use for the purpose of Booting Virtual Machines. I use VMWare Player to boot Windows Guest Operating Systems onto my Linux Laptop. I currently have a SSD drive that I use for this exact same purpose that is formatted as ext3 and I'm... (3 Replies)
Discussion started by: mrm5102
3 Replies
vgchgid(1M)															       vgchgid(1M)

NAME
vgchgid - modify the Volume Group ID (VGID) on a given set of physical devices SYNOPSIS
PhysicalVolumePath [PhysicalVolumePath] ... DESCRIPTION
The command is designed to change the LVM Volume Group ID (VGID) on a supplied set of disks. will work with any type of storage, but it is primarily targeted at disk arrays that are able to create "snapshots" or "clones" of mirrored LUNs. accepts a set of raw physical devices and ensures that they all belong to the same volume group, before altering the VGID (see section). The same VGID is set on all the disks and it should be noted that in cases of multi-PV volume groups, all the physical volumes should be supplied in a single invocation of the command. Options recognizes the following options and arguments: PhysicalVolumePath The raw devices path name of a physical volume. Background Some storage subsystems have a feature which allows a user to split off a set of mirror copies of physical storage (termed or just as LVM splits off logical volumes with the command. As the result of the "split," the split-off devices will have the same VGID as the original disks. is needed to modify the VGID on the BCV devices. Once the VGID has been altered, the BCV disks can be imported into a new volume group by using WARNINGS
Once the VGID has been changed, the original VGID is lost until a disk device is re-mirrored with the original devices. If is used on a subset of disk devices (for example, two out of four disk devices), the two groups of disk devices would not be able to be imported into the same volume group since they have different VGIDs on them. The solution is to re-mirror all four of the disk devices and re-run on all four BCV devices at the same time, and then use to import them into the same new volume group. If a disk is newly added to an existing volume group and no subsequent LVM operations has been performed to alter the structures (in other words, operations which perform an automated vgcfgbackup(1M)); then it is possible a subsequent will fail. It will report that the disk does not belong to the volume group. This may be overcome by performing a structure changing operation on the volume group (for example, using It is the system administrator's responsibility to make sure that the devices provided in the command line are all Business Copy volumes of the existing standard physical volumes and are in the ready state and writable. Mixing the standard and BC volumes in the same volume group can cause data corruption. RETURN VALUE
returns the following values: 0 VGID was modified with no error 1 VGID was not modified EXAMPLES
An example showing how might be used: 1. The system administrator uses the following commands to create the Business Continuity (BCV or BC) copy: 1) For EMC Symmetrix disks, the commands are and 2) For XP disk array, the commands are and Three BCV disks are created. 2. Change the VGID on the BCV disks. 3. Make a new volume group using the BCV disks. This step can be skipped as the group file will be created automatically. If the file is manually created it will have different major and minor numbers (see lvm(7)). 4. Import the BCV disks into the new volume group. 5. Activate the new volume group. 6. Backup the new volume group's LVM data structure. 7. Mount the associated logical volumes. SEE ALSO
vgimport(1M), vgscan(1M), vgcfgbackup(1M). vgchgid(1M)
All times are GMT -4. The time now is 01:21 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy