Sponsored Content
Operating Systems HP-UX Cstm and gsp conflict on power status Post 302953708 by port43 on Monday 31st of August 2015 12:55:04 PM
Old 08-31-2015
The GSP shows, correctly, that slot 1 is "Normal" because the power supply has been replaced. Resetting the GSP with that command did nothing for the status in cstm which shows "component failed" (which it should not be).
 

7 More Discussions You Might Find Interesting

1. HP-UX

How to use CSTM on HP-Ux 11i V2

Hi, Newbie here......I am an new guy on HP-Ux... may i ask all the the guru's and who has eperienced here to enlightened me on how to use the CSTM command. My goal is to view the current HW installed on the Server. Thanks in advance. (1 Reply)
Discussion started by: renobal
1 Replies

2. Red Hat

power supply status in sysreport

Hello guys: I'm a beginner in this exciting world of open spource and linux. I'm working as a support engineer and a customer send back to me a sysreport from his system running redhat 4. the customer has a power supply failed in his server and to see it and justify the replacement I required a... (0 Replies)
Discussion started by: amani
0 Replies

3. HP-UX

Conflict between df -k and du -sk...again

Hi, I know this has been discussed a number of time but i could not get the exact answer. So need help again. Issue: The two command for same file system shows different size. du -sk shows toatl size is 12780685 KB while df -k 45289229 used allocated Kb /oxt/mantran/bin $ du -sk... (8 Replies)
Discussion started by: malaya_17
8 Replies

4. Solaris

Solaris 9 IP conflict

Hi Gurus I am in a strange situation. I have a SUN sparc server . The server was having an IP say X..... (this IP X is now being used by another server)..... I have just installed fresh solaris 9 OS on the same server and given new IP say Y. I also configured probe based IPMP with ce0 and... (2 Replies)
Discussion started by: ningy
2 Replies

5. HP-UX

echo "selall;info;wait;infolog" | /usr/sbin/cstm problem

Hello, On a HP-UX 10.20 server I've executed something similar to this command: # echo 'selall;info;wait;infolog;view;done' | /usr/sbin/cstm But it returns sometype of "argument list too long" error. I suppose there is a way to fix it by using xargs but I can't figure it out. Any... (7 Replies)
Discussion started by: asanchez
7 Replies

6. AIX

Finding Power Supply Status

Hi, As in Management Modules of IBM it is possible to find out wheather out of dual powersupply , if one goes down. is it possible to find out in HMC to find out if one power supply goes down of P Series server? if server is remotely HOw to find out if one power supply of server is down?... (1 Reply)
Discussion started by: manoj.solaris
1 Replies

7. Shell Programming and Scripting

Conflict with the operator in IF

I am using a script like this source=$1 if ; then echo "got it" else echo "lost it" fi But the script is giving th error like script.ksh: ==: unknown test operator Can i know , is the syntax iam using is correct or suggest me a good way. ... (3 Replies)
Discussion started by: nani1984
3 Replies
metareplace(1M) 					  System Administration Commands					   metareplace(1M)

NAME
metareplace - enable or replace components of submirrors or RAID5 metadevices SYNOPSIS
/usr/sbin/metareplace -h /usr/sbin/metareplace [-s setname] -e mirror component /usr/sbin/metareplace [-s setname] mirror component-old component-new /usr/sbin/metareplace [-s setname] -e RAID component /usr/sbin/metareplace [-s setname] [-f] RAID component-old component-new DESCRIPTION
The metareplace command is used to enable or replace components (slices) within a submirror or a RAID5 metadevice. When you replace a component, the metareplace command automatically starts resyncing the new component with the rest of the metadevice. When the resync completes, the replaced component becomes readable and writable. If the failed component has been hot spare replaced, the hot spare is placed in the available state and made available for other hot spare replacements. Note that the new component must be large enough to replace the old component. A component may be in one of several states. The Last Erred and the Maintenance states require action. Always replace components in the Maintenance state first, followed by a resync and validation of data. After components requiring maintenance are fixed, validated, and resynced, components in the Last Erred state should be replaced. To avoid data loss, it is always best to back up all data before replacing Last Erred devices. OPTIONS
Root privileges are required for all of the following options except -h. -e Transitions the state of component to the available state and resyncs the failed component. If the failed component has been hot spare replaced, the hot spare is placed in the available state and made available for other hot spare replace- ments. This command is useful when a component fails due to human error (for example, accidentally turning off a disk), or because the component was physically replaced. In this case, the replacement component must be partitioned to match the disk being replaced before running the metareplace command. -f Forces the replacement of an errored component of a metadevice in which multiple components are in error. The component determined by the metastat display to be in the ``Maintenance'' state must be replaced first. This option may cause data to be fabricated since multiple components are in error. -h Display help message. -s setname Specifies the name of the diskset on which metareplace will work. Using the -s option will cause the command to perform its administrative function within the specified diskset. Without this option, the command will perform its function on local metadevices. mirror The metadevice name of the mirror. component The logical name for the physical slice (partition) on a disk drive, such as /dev/dsk/c0t0d0s2. component-old The physical slice that is being replaced. component-new The physical slice that is replacing component-old. RAID The metadevice name of the RAID5 device. EXAMPLES
Example 1 Recovering from Error Condition in RAID5 Metadevice This example shows how to recover when a single component in a RAID5 metadevice is errored. # metareplace d10 c3t0d0s2 c5t0d0s2 In this example, a RAID5 metadevice d10 has an errored component, c3t0d0s2, replaced by a new component, c5t0d0s2. Example 2 Use of -e After Physical Disk Replacement This example shows the use of the -e option after a physical disk in a submirror (a submirror of mirror mymirror1, in this case) has been replaced. # metareplace -e mymirror1 c1t4d0s2 Note: The replacement disk must be partitioned to match the disk it is replacing before running the metareplace command. EXIT STATUS
The following exit values are returned: 0 Successful completion. >0 An error occurred. ATTRIBUTES
See attributes(5) for descriptions of the following attributes: +-----------------------------+-----------------------------+ | ATTRIBUTE TYPE | ATTRIBUTE VALUE | +-----------------------------+-----------------------------+ |Availability |SUNWmdu | +-----------------------------+-----------------------------+ |Interface Stability |Stable | +-----------------------------+-----------------------------+ SEE ALSO
mdmonitord(1M), metaclear(1M), metadb(1M), metadetach(1M), metahs(1M), metainit(1M), metaoffline(1M), metaonline(1M), metaparam(1M), metarecover(1M), metarename(1M), metaroot(1M), metaset(1M), metassist(1M), metastat(1M), metasync(1M), metattach(1M), md.tab(4), md.cf(4), mddb.cf(4), md.tab(4), attributes(5), md(7D) SunOS 5.11 26 Mar 2006 metareplace(1M)
All times are GMT -4. The time now is 05:49 AM.