Sponsored Content
Operating Systems HP-UX Expert Recovery Shell - Fatal Error: Unrecognized disk layout Post 302949961 by Peasant on Saturday 18th of July 2015 03:13:12 AM
Old 07-18-2015
Do you have other disks inside on which you can install hpux v3 ?

If you can install on another disk, you should be able to mount the disk in question after installing the required depot drivers.

At least you will be able to access the data on them and manipulate them in certain ways.

What kind of mirror is it (controller or LVM)

It is a good practice to have ignite backups.Smilie
 

10 More Discussions You Might Find Interesting

1. UNIX for Advanced & Expert Users

Fatal error in disk

I have a doubt with an error message, and i want to be sure if this is a normal situation or not. Situation: I was formating and installing a SCSI 36Gb HD with UNIX SCO 5.05, the problem happens when is making the division and filesystem on disk 1, and the message error is "Exit value 139... (1 Reply)
Discussion started by: jav_v
1 Replies

2. UNIX for Dummies Questions & Answers

Disk layout

Apologize if I hurt anyone's head with my questions, I'm entirely new to Unix and my office here doesn't offer any training just learn as you go. Anyways they asked me to get a disk layout of one of our servers and gave me this as an example the lables are assumptions Disk ... (2 Replies)
Discussion started by: newdigitalblue
2 Replies

3. Solaris

Unable to understand disk layout and where are the free space

Hi I am unable to understand the disk layout of one of my disk attached to v240. This is newly installed system from jumpstart. I am unable to see the free space on backup slice 2 and there are 0 to 8 slices listed when I run format and print the disk info, also there is no reference of... (9 Replies)
Discussion started by: kumarmani
9 Replies

4. UNIX for Advanced & Expert Users

Veritas Volume Manager question (Disk layout with 4 plexes)

I am trying to build a veritas volume similar to an existing volume on another server. The output on source server is: usbtor12# vxprint -hrtg appdg v anvil_sqlVOL - ENABLED ACTIVE 629145600 SELECT - fsgen pl anvil_sqlVOL-01 anvil_sqlVOL ENABLED ACTIVE 629145600... (3 Replies)
Discussion started by: momin313
3 Replies

5. Hardware

Unrecognized disk label of a external HD

I have a external HD that I can't seem to open. When I try to open it with gparted it says unrecognized disk. When I run gparted from the terminal this is what it says. ~ $ sudo gparted ====================== libparted : 2.2 ====================== /dev/sdb: unrecognised disk label When I... (18 Replies)
Discussion started by: cokedude
18 Replies

6. AIX

cannot understand my disk layout

my users has requested more space to a particular volume group, so i do a lsvg honda:/tmp/ab/ecc # lsvg rootvg OP24BCKVG OP24ORAvg OP24SYSVG OP24DATVG the user wants to know what disks are available to be added to any of the vgs listed above, (not including rootvg) so i do a lspv... (2 Replies)
Discussion started by: asyed123
2 Replies

7. Hardware

Unrecognized disk label on my external HD

Hi everyone, I have an external hard drive and I accidentally deleted the partition table. Can I restore my files? If I try to run the f-disk command this is what it says Disk /dev/sda: 320.1 GB, 320072933376 bytes 255 heads, 63 sectors/track, 38913 cylinders, total 625142448 sectors Units =... (1 Reply)
Discussion started by: Sampa
1 Replies

8. SCO

Unsuccessful install due to unrecognized disk issue

Dear Community! i try to instaled the sco 6 in hp proliant ML350g8 but unsucces, the trouble when i do instaled it undetected hardisk please help me :(:o (7 Replies)
Discussion started by: mnr
7 Replies

9. Solaris

Unrecognized option: sparc-sun-Solaris2.10/bin/as: unrecognized option `-m32'

Hi, I installed some packages required by an app built with python. But when I try python setup.py install, I get the following error: /opt/csw/lib/gcc/sparc-sun-solaris2.10/5.2.0/../../../../sparc-sun-solaris2.10/bin/as: unrecognized option `-m32' Could anyone tell me what's wrong... (4 Replies)
Discussion started by: Kimkun
4 Replies

10. What is on Your Mind?

PHP Fatal Errors During SSL Cert Management - PHP Fatal error: xc_fcntl_mutex failed

Today, I noticed some errors in our SSL cert renewal log files, mostly related to domains where the IP address had changed. Concerned about this, rebuilt out SSL cert, which normally goes well without a hiccup. However, for today, for some reason which I cannot explain, there was a PHP error... (0 Replies)
Discussion started by: Neo
0 Replies
vgchgid(1M)															       vgchgid(1M)

NAME
vgchgid - modify the Volume Group ID (VGID) on a given set of physical devices SYNOPSIS
PhysicalVolumePath [PhysicalVolumePath] ... DESCRIPTION
The command is designed to change the LVM Volume Group ID (VGID) on a supplied set of disks. will work with any type of storage, but it is primarily targeted at disk arrays that are able to create "snapshots" or "clones" of mirrored LUNs. accepts a set of raw physical devices and ensures that they all belong to the same volume group, before altering the VGID (see section). The same VGID is set on all the disks and it should be noted that in cases of multi-PV volume groups, all the physical volumes should be supplied in a single invocation of the command. Options recognizes the following options and arguments: PhysicalVolumePath The raw devices path name of a physical volume. Background Some storage subsystems have a feature which allows a user to split off a set of mirror copies of physical storage (termed or just as LVM splits off logical volumes with the command. As the result of the "split," the split-off devices will have the same VGID as the original disks. is needed to modify the VGID on the BCV devices. Once the VGID has been altered, the BCV disks can be imported into a new volume group by using WARNINGS
Once the VGID has been changed, the original VGID is lost until a disk device is re-mirrored with the original devices. If is used on a subset of disk devices (for example, two out of four disk devices), the two groups of disk devices would not be able to be imported into the same volume group since they have different VGIDs on them. The solution is to re-mirror all four of the disk devices and re-run on all four BCV devices at the same time, and then use to import them into the same new volume group. If a disk is newly added to an existing volume group and no subsequent LVM operations has been performed to alter the structures (in other words, operations which perform an automated vgcfgbackup(1M)); then it is possible a subsequent will fail. It will report that the disk does not belong to the volume group. This may be overcome by performing a structure changing operation on the volume group (for example, using It is the system administrator's responsibility to make sure that the devices provided in the command line are all Business Copy volumes of the existing standard physical volumes and are in the ready state and writable. Mixing the standard and BC volumes in the same volume group can cause data corruption. RETURN VALUE
returns the following values: 0 VGID was modified with no error 1 VGID was not modified EXAMPLES
An example showing how might be used: 1. The system administrator uses the following commands to create the Business Continuity (BCV or BC) copy: 1) For EMC Symmetrix disks, the commands are and 2) For XP disk array, the commands are and Three BCV disks are created. 2. Change the VGID on the BCV disks. 3. Make a new volume group using the BCV disks. This step can be skipped as the group file will be created automatically. If the file is manually created it will have different major and minor numbers (see lvm(7)). 4. Import the BCV disks into the new volume group. 5. Activate the new volume group. 6. Backup the new volume group's LVM data structure. 7. Mount the associated logical volumes. SEE ALSO
vgimport(1M), vgscan(1M), vgcfgbackup(1M). vgchgid(1M)
All times are GMT -4. The time now is 01:30 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy