02-01-2015
Quote:
Originally Posted by
bartus11
If adding more disks is possible, then you could create mirrored vdevs, by attaching mirror disks to c3t5000CCA012B3E751d0 and c3t5000CCA012B39541d0. See manual for zpool attach command.
Why not just wipe out the zpool mirror that I just added and mirror using those? Pretty much out of disks at this point.
10 More Discussions You Might Find Interesting
1. Solaris
I had a pool which was exported and due to some issues on my SAN i was never able to import it again. Can anyone tell me how can i destroy the exported pool to free up the LUN. I tried to create a new pool on the same pool but it gives me following error
# zpool create emcpool4 emcpower0c... (0 Replies)
Discussion started by: fugitive
0 Replies
2. Solaris
I am not seeing anyway to remove a LUN from a Zpool...
Am I missing something? or do i have to destroy the zpool and recreate it? (2 Replies)
Discussion started by: BG_JrAdmin
2 Replies
3. Red Hat
Hi Everyone,
I have added new Virtual disk to OS. The main point is I need to bring this whole Disk into LVM control, is it necessary to partition the disk using fdisk command and assign partition type as '8e', or can I directly add that disk into LVM, by running pvcreate command with out... (2 Replies)
Discussion started by: bobby320
2 Replies
4. AIX
Hi
I have one of the disk missing in my NIMVG. My doubt is can I remove this hdisk2 online ? few of the file systems seems to be spread over 7 PV's. that's why i'm worried. Can someone suggest if I can replace this disk online. Also how to check if there is some data present in hdisk2 alone... (2 Replies)
Discussion started by: newtoaixos
2 Replies
5. Solaris
Hi ,
One of my zone went down and when i booted it up i could see the pool in degraded state with some check sum errors . we have brought the pool online after scrubbing. But few files are showing this error
Bad exchange descriptor
Please let me know how to remove these files (2 Replies)
Discussion started by: chidori
2 Replies
6. Solaris
Hi,
Quick question.
I have a data zpool that consists of 1 disk.
pool: data
state: ONLINE
scrub: none requested
config:
NAME STATE READ WRITE CKSUM
data ONLINE 0 0 0
c0t50002AC0014B06BEd0 ONLINE... (2 Replies)
Discussion started by: general_lee
2 Replies
7. AIX
Dear All,
I created a new partition through "Integrated Virtualization Manager" but there have an error when I added a new disk to the partition. The disk already created without any issue,
Below error is to add the disk to the partition
An error occured while modifying the assignments... (5 Replies)
Discussion started by: lckdanny
5 Replies
8. Solaris
Hello,
I need some help in recovering ZFS pool. Here is scenerio. There are two disks -
c0t0d0 - This is good disk. I cloned it from other server and boot server from this disk.
c0t1d0 - This is original disk of this server, having errors. I am able to mount it on /mnt. So that I can copy... (1 Reply)
Discussion started by: solaris_1977
1 Replies
9. Solaris
issue,
I had a zpool which was full
pool_temp1 199G 197G 1.56G 99% ONLINE -
pool_temp2 199G 196G 3.09G 98% ONLINE -
as you can see, full
so I replaced with a larger disk.
zpool replace pool_temp1 c3t600144F0FF8BA036000058CC1DB80008d0s0... (2 Replies)
Discussion started by: rrodgers
2 Replies
10. Solaris
On an OmniOS server, I removed a single-disk pool I was using for testing.
Now, when I run zpool import it will show it as FAULTED, since that single disk not available anymore.
# zpool import
pool: fido
id: 7452075738474086658
state: FAULTED
status: The pool was last... (11 Replies)
Discussion started by: priyadarshan
11 Replies
vgchgid(1M) vgchgid(1M)
NAME
vgchgid - modify the Volume Group ID (VGID) on a given set of physical devices
SYNOPSIS
PhysicalVolumePath [PhysicalVolumePath] ...
DESCRIPTION
The command is designed to change the LVM Volume Group ID (VGID) on a supplied set of disks. will work with any type of storage, but it is
primarily targeted at disk arrays that are able to create "snapshots" or "clones" of mirrored LUNs. accepts a set of raw physical devices
and ensures that they all belong to the same volume group, before altering the VGID (see section).
The same VGID is set on all the disks and it should be noted that in cases of multi-PV volume groups, all the physical volumes should be
supplied in a single invocation of the command.
Options
recognizes the following options and arguments:
PhysicalVolumePath The raw devices path name of a physical volume.
Background
Some storage subsystems have a feature which allows a user to split off a set of mirror copies of physical storage (termed or just as LVM
splits off logical volumes with the command. As the result of the "split," the split-off devices will have the same VGID as the original
disks. is needed to modify the VGID on the BCV devices. Once the VGID has been altered, the BCV disks can be imported into a new volume
group by using
WARNINGS
Once the VGID has been changed, the original VGID is lost until a disk device is re-mirrored with the original devices. If is used on a
subset of disk devices (for example, two out of four disk devices), the two groups of disk devices would not be able to be imported into
the same volume group since they have different VGIDs on them. The solution is to re-mirror all four of the disk devices and re-run on all
four BCV devices at the same time, and then use to import them into the same new volume group.
If a disk is newly added to an existing volume group and no subsequent LVM operations has been performed to alter the structures (in other
words, operations which perform an automated vgcfgbackup(1M)); then it is possible a subsequent will fail. It will report that the disk
does not belong to the volume group. This may be overcome by performing a structure changing operation on the volume group (for example,
using
It is the system administrator's responsibility to make sure that the devices provided in the command line are all Business Copy volumes of
the existing standard physical volumes and are in the ready state and writable. Mixing the standard and BC volumes in the same volume
group can cause data corruption.
RETURN VALUE
returns the following values:
0 VGID was modified with no error
1 VGID was not modified
EXAMPLES
An example showing how might be used:
1. The system administrator uses the following commands to create the Business Continuity (BCV or BC) copy:
1) For EMC Symmetrix disks, the commands are and
2) For XP disk array, the commands are and
Three BCV disks are created.
2. Change the VGID on the BCV disks.
3. Make a new volume group using the BCV disks.
This step can be skipped as the group file will be created automatically. If the file is manually created it will have different major
and minor numbers (see lvm(7)).
4. Import the BCV disks into the new volume group.
5. Activate the new volume group.
6. Backup the new volume group's LVM data structure.
7. Mount the associated logical volumes.
SEE ALSO
vgimport(1M), vgscan(1M), vgcfgbackup(1M).