First off, i wouldn't want to run HACMP 7.1.3 off an 6.1 LPAR. I strongly suggest to update to 7.1.3 SP3 from May. Do not forget the two necessary efixes.

Two probable causes for your problem come to mind: have you zoned the LUN for concurrent access? Second, Repository disks are supported via NPIV only if the storage is IBM (yes, thanks a lot, IBM, for that open system). As you use EMC storage (like me) you have to provide the disk via iSCSI, which means via the VIOS.

Please tell us how the Repo-disk is connected to the system, which driver suite you use for your FC adapters - in short, describe your system better.

Moderator's Comments:
Mod Comment by the way: we have an AIX board, so please write your AIX-related questions there. I move this thread over.


I hope this helps.

bakunin
 

10 More Discussions You Might Find Interesting

1. AIX

Oracle and SAP on AIX 6.1 + PowerHA resources ?

I was wondering if any one have any guides or documention regarding Oracle and SAP on AIX 6.1 + PowerHA setups in one guide step by step Thanks (2 Replies)
Discussion started by: h@foorsa.biz
2 Replies

2. AIX

PowerHA - assistant can't find network

I've configured multiple clusters using PowerHA 5.5, but never using the 'Two-node cluster configuration assistant'. I removed all the clusters, clean setup, and gave the assistant a try. I've filled in all the necessary options: Communication Path to Takeover Node Application Server ... (11 Replies)
Discussion started by: Koen87
11 Replies

3. AIX

PowerHA, same subnet for persistent and service ip

I am new in AIX and please forgive my poor english. I know that AIX allow same subnet IPs for different interfaces, which result in multipath routing / route striping. My question is, is there any best practice for the persistent and service IP with same subnet to stay on same interface, or... (5 Replies)
Discussion started by: skeyeung
5 Replies

4. AIX

PowerHA Disk on VIO Server

Hello AIX GURU's Can anybody tell me the steps to crate shared VG (enhanced concurent) for my Lpars from VIO server? my questions are: 1. Should I crate Enhanced Concurent VG in VIO and map it using virtual Scsi to Lpar? or 2. Can I just create virtual SCSI in VIO and map to Lpar and... (1 Reply)
Discussion started by: Vit0_Corleone
1 Replies

5. AIX

PowerHA with 3rd node for communication

Looking to find PowerHA with 3rd node used for communication (voting node) only. Does anyone use such configuration with IBM products? (2 Replies)
Discussion started by: gogogo
2 Replies

6. AIX

PowerHA HACMP on VIOS servers

Few questions regarding Power HA ( previously known as HACMP) and VIOS POWERVM IVM ( IBM Virtualization I/O Server ) Is it possible to create HACMP cluster between two VIOS servers Physical Machine_1 VIOS_SERVER_1 LPAR_1 SHARED_DISK_XX VIOS_SERVER_2 Physical Machine_2 LPAR_2... (6 Replies)
Discussion started by: filosophizer
6 Replies

7. AIX

PowerHA 5.5.0.4 on AIX 5.3 TL10 upgrade question

Hi all, I want to upgrade a clustered AIX 5.3 TL10 with PowerHA 5.5.0.4. To both AIX 6.1 and PowerHA 6.1 in an wasy way. Any guidelines or procedures in an easy way to accomplish this task safely? Note : fdown time is an acceptable option. (2 Replies)
Discussion started by: h@foorsa.biz
2 Replies

8. AIX

VXVM in POWERHA 6.1

I have created a VxVM disk group in AIX7.1. I have tried to added this VxVM disk group in powerHA 6.1. But in cluster VxVM DGs are not listing. Is there any other procedure to add vxvm diskgroup to hacmp. Please share me steps for adding vxvm diskgroup to hacmp. (6 Replies)
Discussion started by: sunnybee
6 Replies

9. AIX

PowerHa 7.1 Migration check failed

Hello Guys, I was trying to upgrade the PowerHA from 6.1.0.9 to 7.1.3 in prod cluster. Have snapshot migration and run climgcheck. 1. Run climgcheck on node1(kul1pqcmur01) and it success 2. Upgrade the cluster sw 3. Run climgcheck on node2(kul1pqcmur02) and it failed with below errors ... (6 Replies)
Discussion started by: novaothers
6 Replies

10. AIX

Upgrading PowerHA from 7.1.0 to 7.1.3

Hi All, As per the IBM upgrade/support matrix IBM Techdocs Technote: PowerHA for AIX Version Compatibility Matrix we can't do online upgrade or rolling migration from powerha v7.1.0 to v7.1.3. on AIX61_TL9_SP4, So we are following the steps as below ... 1 ) Bring down the cluster 2 )... (2 Replies)
Discussion started by: linux.amrit
2 Replies
vgchgid(1M)															       vgchgid(1M)

NAME
vgchgid - modify the Volume Group ID (VGID) on a given set of physical devices SYNOPSIS
PhysicalVolumePath [PhysicalVolumePath] ... DESCRIPTION
The command is designed to change the LVM Volume Group ID (VGID) on a supplied set of disks. will work with any type of storage, but it is primarily targeted at disk arrays that are able to create "snapshots" or "clones" of mirrored LUNs. accepts a set of raw physical devices and ensures that they all belong to the same volume group, before altering the VGID (see section). The same VGID is set on all the disks and it should be noted that in cases of multi-PV volume groups, all the physical volumes should be supplied in a single invocation of the command. Options recognizes the following options and arguments: PhysicalVolumePath The raw devices path name of a physical volume. Background Some storage subsystems have a feature which allows a user to split off a set of mirror copies of physical storage (termed or just as LVM splits off logical volumes with the command. As the result of the "split," the split-off devices will have the same VGID as the original disks. is needed to modify the VGID on the BCV devices. Once the VGID has been altered, the BCV disks can be imported into a new volume group by using WARNINGS
Once the VGID has been changed, the original VGID is lost until a disk device is re-mirrored with the original devices. If is used on a subset of disk devices (for example, two out of four disk devices), the two groups of disk devices would not be able to be imported into the same volume group since they have different VGIDs on them. The solution is to re-mirror all four of the disk devices and re-run on all four BCV devices at the same time, and then use to import them into the same new volume group. If a disk is newly added to an existing volume group and no subsequent LVM operations has been performed to alter the structures (in other words, operations which perform an automated vgcfgbackup(1M)); then it is possible a subsequent will fail. It will report that the disk does not belong to the volume group. This may be overcome by performing a structure changing operation on the volume group (for example, using It is the system administrator's responsibility to make sure that the devices provided in the command line are all Business Copy volumes of the existing standard physical volumes and are in the ready state and writable. Mixing the standard and BC volumes in the same volume group can cause data corruption. RETURN VALUE
returns the following values: 0 VGID was modified with no error 1 VGID was not modified EXAMPLES
An example showing how might be used: 1. The system administrator uses the following commands to create the Business Continuity (BCV or BC) copy: 1) For EMC Symmetrix disks, the commands are and 2) For XP disk array, the commands are and Three BCV disks are created. 2. Change the VGID on the BCV disks. 3. Make a new volume group using the BCV disks. This step can be skipped as the group file will be created automatically. If the file is manually created it will have different major and minor numbers (see lvm(7)). 4. Import the BCV disks into the new volume group. 5. Activate the new volume group. 6. Backup the new volume group's LVM data structure. 7. Mount the associated logical volumes. SEE ALSO
vgimport(1M), vgscan(1M), vgcfgbackup(1M). vgchgid(1M)