Operating Systems AIX Problems with VIO O/S 2.2.3 Post 302891179 by -=XrAy=- on Tuesday 4th of March 2014 09:27:00 AM
Old 03-04-2014
Hi,

i use the IBM System Planning Tool to understand Your configuration and "problem".

1. Which Storage Backplane do you use (EJ0D, EJ0E or EJ0F) ?
2. In all cases max. 6 SFF Drives are possible - do you use a additional IO-Drawer?

The IBM System Planning Tool shows that P1-C18 points to the SAS Controller and P1-C8 to the GX++ Slot.

Regards
 

10 More Discussions You Might Find Interesting

1. AIX

Problems installing AIX on vio

I've been trying to get AIX 5.3 installed on a vio partition. I tried one partition that I created, and another one that already had AIX 5.3 on it. In both cases, the install seems to be successful, but when it tries to reboot, it gets to the kernel starting phase, I can see the kernel size, and... (0 Replies)
Discussion started by: Morella
0 Replies

2. AIX

Backup of VIO

I have a script running remotely using viosvrcmd command on hmc to back up the VIO servers. these are the steps involved 1. Mount the NFS directory on to the VIO server 2. run backupios command 3. un mount the directory I am stuck up in the 3rd step. I am not able to unmount the nfs... (6 Replies)
Discussion started by: balaji_prk
6 Replies

3. AIX

vio server and vio client

Hi, I want to know wheather partition size for installation of vio client can be specified on vio server example If I am installing vio server on blade with 2*300gb hard disk,after that I want to create 2 vio client (AIX Operating system) wheather I can specify hard disk size while... (1 Reply)
Discussion started by: manoj.solaris
1 Replies

4. AIX

vio related

In a dual vio, how will u know one lpar is in which vio? (1 Reply)
Discussion started by: shobhan.murthy
1 Replies

5. AIX

Vio Build

I am planning carving out dual VIO servers on a P750 based and would like to know how to allocate internal disks to the VIOS. This has 4 internal disks and I would to assign 2 disks to each VIO. This is what I was thinking of assigning . Any advise? vio1 U5802.001.9K8H757-P1-C1 PCI-E x8... (17 Replies)
Discussion started by: mk8570
17 Replies

6. AIX

sddpcm on vio

I have same lun (hdisk3) assigned to 2 vios server (dual vio server) and this is mapped to the client lpar. I have sddpcm on the VIO. On the VIOA, the attributes for fscsi1 and fscsi3 are set to fast_fail and dyntrk is set to yes Now, if I do a lqueryvg -Atp on the hdisk3, I get a "DISK... (4 Replies)
Discussion started by: mk8570
4 Replies

7. Red Hat

vio in linux

I am working in AIX. In a P series machine both aix and linux os can install.. specific command is there for aix to list out the vio servers details mapped in a frame(ie. lssrc "IBM.ManagementServer", like that..) is there any command is der to list out vio servers details in linux or how to find... (1 Reply)
Discussion started by: muralikrish
1 Replies

8. AIX

vio server ethernet to vio client ethernet(concepts confusing)

Hi In the vio server when I do # lsattr -El hdisk*, I get a PVID. The same PVID is also seen when I put the lspv command on the vio client partition. This way Im able to confirm the lun using the PVID. Similarly how does the vio client partition gets the virtual ethernet scsi client adapter... (1 Reply)
Discussion started by: newtoaixos
1 Replies

9. AIX

VIO Server

Hi, I am facing an issue in vio server. When I run bosboot -ad /dev/hdisk0 I am getting an error trustchk: Verification of attributes failed: /usr/sbin/bootinfo : accessauths regards, vjm Please use code tags next time for your code and data. (8 Replies)
Discussion started by: vjm
8 Replies

10. AIX

Reboot VIO - OK?

We've got two datacenters and in every datacenter 2 VIOs. The VIO manages the I/O of the LPARs. So: Is it possible to reboot the VIO without shuting down an LPAR:wall: (4 Replies)
Discussion started by: DiViN3
4 Replies
AAC(4)							   BSD Kernel Interfaces Manual 						    AAC(4)

NAME
aac -- Adaptec AdvancedRAID Controller driver SYNOPSIS
aac* at pci? dev ? function ? ld* at aac? unit ? DESCRIPTION
The aac driver provides support for the Adaptec AAC family of SCSI and SATA RAID controllers. These controllers support RAID 0, 1, 5, 10, and volume sets. They have four channels in the add-in version or 1-2 channels in the motherboard integrated version, and are most often found rebadged by Dell, Hewlett-Packard or IBM. Supported controllers include: o Adaptec AAC-364 o Adaptec SCSI RAID 2120S o Adaptec SCSI RAID 2200S o Adaptec SATA RAID 2410SA o Adaptec SATA RAID 3405 o Adaptec SCSI RAID 5400S o Dell PERC 2/Si o Dell PERC 2/QC o Dell PERC 3/Di o Dell PERC 3/Si o Dell PERC 320/DC o Dell CERC SATA RAID 1.5/6ch o HP NetRAID 4M o HP ML110 G2 (Adaptec SATA RAID 2610SA) o IBM ServeRAID 8k Access to RAID containers is available via the ld device driver. Individual drives cannot be accessed unless they are part of a container or volume set, and non-fixed disks cannot be accessed. Containers can be configured by using the on-board BIOS utility of the card. DIAGNOSTICS
The adapter can send status and alert messages asynchronously to the driver. These messages are printed on the system console. SEE ALSO
intro(4), ld(4) HISTORY
The aac driver first appeared in NetBSD 1.6, and was based on the FreeBSD driver of the same name. BUGS
This driver is not compatible with controllers that have version 1.x firmware. The firmware version is the same as the kernel version printed in the BIOS POST and driver attach messages. BSD
February 19, 2011 BSD
All times are GMT -4. The time now is 02:47 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy