Sponsored Content
Full Discussion: Disk controller reassignment
Operating Systems Solaris Disk controller reassignment Post 302818663 by hicksd8 on Saturday 8th of June 2013 06:54:08 AM
Old 06-08-2013
@bartus11....I agree with you but what possible explanation is there for Solaris to decide to mirror a 300GB drive to a 600GB drive, all on its own on a new build???

How does that possibly work???

The only way that I can think of is a pre-existing hardware RAID configuration.
 

10 More Discussions You Might Find Interesting

1. UNIX for Advanced & Expert Users

Controller Naming

Hello all, How does the Solaris identifies the controller subscript ? ( like c0txdxs0 or c1txdxsx ?? ) I have a unix box ( Ultra 30) running with 2.5.1. When I connected an external hard disk to the on-board scsi port, it got identified as c0t1dxsx... (... (1 Reply)
Discussion started by: shibz
1 Replies

2. Solaris

Controller target disk?

Hi, I am a newbie to Solaris. I want to know how to find out the controller target and disk number on a SunFire V890 box that has 6X72GB disks. The probe-scsi output is as shown below: /pci@8,600000/SUNW,qlc@2 LiD HA LUN --- Port WWN --- ----- Disk description ----- 0 0 0 ... (1 Reply)
Discussion started by: sudhir_shet
1 Replies

3. Solaris

changing controller name

Dear Solarizer, If i have a disk let say like this c1t0d0s0 How to change the controller to be come example : c3t0d0s0 Thanxs For your replay Regads, tpx (3 Replies)
Discussion started by: tpx99
3 Replies

4. SCO

Warning HD: no root disk controller was found

hi... i hav a problem to install sco unix while installing sco unix 5.0.5 in acer altos with hardware raid am getting error "Warning HD: no root disk controller was found system error 5: while getting fs type flushing controller: DAC960PRL cache done." i hav use the following... (18 Replies)
Discussion started by: mselvaprakash
18 Replies

5. HP-UX

[Joy Share] - Replace an unknown status controller on HP FC60 disk array

Replace an unknown status controller on HP FC60 disk array Author:JoyOnline JoyChangLu@gmail.com Trouble description: The users detected that the status of controller at A is unknown. Analysis and diagnostic: Physical observed all leds on enclosure of disk array is normal. The... (4 Replies)
Discussion started by: JoyOnLine
4 Replies

6. SCO

SCO 5.0.7 no root disk controller found error during install

I'm "attempting" to install SCO 5.0.7 on an HP ML370 G4 server and am ready to bash the keyboard with head now. I keep getting the error message "WARNING hd: no root disk controller found" when running the bootable install cd. I have a raid 5 array with an online spare created using 4 36.3 GB... (2 Replies)
Discussion started by: FrictionBurn
2 Replies

7. Solaris

Help needed to find out the disk controller for veritas disks

hi all i am using vxvm 5.1 on my sun blade 150 which is running with solaris 5.10. When i give the command "vxdisk list" it gives the following output # vxdisk list DEVICE TYPE DISK GROUP STATUS c0t0d0s2 auto:none - - online... (2 Replies)
Discussion started by: kingston
2 Replies

8. SCO

Change Disk controller in SCO 6.0.0

So today I tried to upgrade a customer from a Proliant with an HPSAS controller to an Intel server with a MEGASAS controller. First, I downloaded the megasas driver from SCO and installed it on the old system. Then I created a new Microlite Edge emergency boot cd with the new driver on it. I... (2 Replies)
Discussion started by: jgt
2 Replies

9. Solaris

Changed disk controller -> drops into GRUB?!

I changed disk controller. Unplugged every disk, inserted another controller card, an IBM M1015. The disks are recognized in BIOS, and the controller card's BIOS shows up. But after that, I drop into GRUB and a prompt. That is all. How shall I solve this problem? I am thinking of booting from... (2 Replies)
Discussion started by: kebabbert
2 Replies

10. Solaris

Sun Fire v440 Hard disk or controller broken? WARNING: /pci@1f,700000/scsi@2/sd@0,0 (sd1)

Hi, I have a Sun Fire V440 server that fails to boot up correctly. A lot of services are not started and the sytems acts really slow to commands. During boot I can see the following Error: WARNING: /pci@1f,700000/scsi@2/sd@0,0 (sd1): SCSI transport failed: reason 'reset': retrying... (15 Replies)
Discussion started by: oliwei
15 Replies
MFI(4)							   BSD Kernel Interfaces Manual 						    MFI(4)

NAME
mfi -- LSI Logic & Dell MegaRAID SAS RAID controller SYNOPSIS
mfi* at pci? dev ? function ? DESCRIPTION
The mfi driver provides support for the MegaRAID SAS family of RAID controllers, including: - Dell PERC 5/e, PERC 5/i, PERC 6/e, PERC 6/i - Intel RAID Controller SRCSAS18E, SRCSAS144E - LSI Logic MegaRAID SAS 8208ELP, MegaRAID SAS 8208XLP, MegaRAID SAS 8300XLP, MegaRAID SAS 8308ELP, MegaRAID SAS 8344ELP, MegaRAID SAS 8408E, MegaRAID SAS 8480E, MegaRAID SAS 8708ELP, MegaRAID SAS 8888ELP, MegaRAID SAS 8880EM2, MegaRAID SAS 9260-8i - IBM ServeRAID M1015, ServeRAID M5014 These controllers support RAID 0, RAID 1, RAID 5, RAID 6, RAID 10, RAID 50 and RAID 60 using either SAS or SATA II drives. Although the controllers are actual RAID controllers, the driver makes them look just like SCSI controllers. All RAID configuration is done through the controllers' BIOSes. mfi supports monitoring of the logical disks in the controller through the bioctl(8) and envstat(8) commands. EVENTS
The mfi driver is able to send events to powerd(8) if a logical drive in the controller is not online. The state-changed event will be sent to the /etc/powerd/scripts/sensor_drive script when such condition happens. SEE ALSO
intro(4), pci(4), scsi(4), sd(4), bioctl(8), envstat(8), powerd(8) HISTORY
The mfi driver first appeared in NetBSD 4.0. BSD
March 22, 2012 BSD
All times are GMT -4. The time now is 11:10 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.