Operating Systems Solaris Disk controller reassignment Post 302818663 by hicksd8 on Saturday 8th of June 2013 06:54:08 AM
Old 06-08-2013
@bartus11....I agree with you but what possible explanation is there for Solaris to decide to mirror a 300GB drive to a 600GB drive, all on its own on a new build???

How does that possibly work???

The only way that I can think of is a pre-existing hardware RAID configuration.
 

10 More Discussions You Might Find Interesting

1. UNIX for Advanced & Expert Users

Controller Naming

Hello all, How does the Solaris identifies the controller subscript ? ( like c0txdxs0 or c1txdxsx ?? ) I have a unix box ( Ultra 30) running with 2.5.1. When I connected an external hard disk to the on-board scsi port, it got identified as c0t1dxsx... (... (1 Reply)
Discussion started by: shibz
1 Replies

2. Solaris

Controller target disk?

Hi, I am a newbie to Solaris. I want to know how to find out the controller target and disk number on a SunFire V890 box that has 6X72GB disks. The probe-scsi output is as shown below: /pci@8,600000/SUNW,qlc@2 LiD HA LUN --- Port WWN --- ----- Disk description ----- 0 0 0 ... (1 Reply)
Discussion started by: sudhir_shet
1 Replies

3. Solaris

changing controller name

Dear Solarizer, If i have a disk let say like this c1t0d0s0 How to change the controller to be come example : c3t0d0s0 Thanxs For your replay Regads, tpx (3 Replies)
Discussion started by: tpx99
3 Replies

4. SCO

Warning HD: no root disk controller was found

hi... i hav a problem to install sco unix while installing sco unix 5.0.5 in acer altos with hardware raid am getting error "Warning HD: no root disk controller was found system error 5: while getting fs type flushing controller: DAC960PRL cache done." i hav use the following... (18 Replies)
Discussion started by: mselvaprakash
18 Replies

5. HP-UX

[Joy Share] - Replace an unknown status controller on HP FC60 disk array

Replace an unknown status controller on HP FC60 disk array Author:JoyOnline JoyChangLu@gmail.com Trouble description: The users detected that the status of controller at A is unknown. Analysis and diagnostic: Physical observed all leds on enclosure of disk array is normal. The... (4 Replies)
Discussion started by: JoyOnLine
4 Replies

6. SCO

SCO 5.0.7 no root disk controller found error during install

I'm "attempting" to install SCO 5.0.7 on an HP ML370 G4 server and am ready to bash the keyboard with head now. I keep getting the error message "WARNING hd: no root disk controller found" when running the bootable install cd. I have a raid 5 array with an online spare created using 4 36.3 GB... (2 Replies)
Discussion started by: FrictionBurn
2 Replies

7. Solaris

Help needed to find out the disk controller for veritas disks

hi all i am using vxvm 5.1 on my sun blade 150 which is running with solaris 5.10. When i give the command "vxdisk list" it gives the following output # vxdisk list DEVICE TYPE DISK GROUP STATUS c0t0d0s2 auto:none - - online... (2 Replies)
Discussion started by: kingston
2 Replies

8. SCO

Change Disk controller in SCO 6.0.0

So today I tried to upgrade a customer from a Proliant with an HPSAS controller to an Intel server with a MEGASAS controller. First, I downloaded the megasas driver from SCO and installed it on the old system. Then I created a new Microlite Edge emergency boot cd with the new driver on it. I... (2 Replies)
Discussion started by: jgt
2 Replies

9. Solaris

Changed disk controller -> drops into GRUB?!

I changed disk controller. Unplugged every disk, inserted another controller card, an IBM M1015. The disks are recognized in BIOS, and the controller card's BIOS shows up. But after that, I drop into GRUB and a prompt. That is all. How shall I solve this problem? I am thinking of booting from... (2 Replies)
Discussion started by: kebabbert
2 Replies

10. Solaris

Sun Fire v440 Hard disk or controller broken? WARNING: /pci@1f,700000/scsi@2/sd@0,0 (sd1)

Hi, I have a Sun Fire V440 server that fails to boot up correctly. A lot of services are not started and the sytems acts really slow to commands. During boot I can see the following Error: WARNING: /pci@1f,700000/scsi@2/sd@0,0 (sd1): SCSI transport failed: reason 'reset': retrying... (15 Replies)
Discussion started by: oliwei
15 Replies
dpt(7D) 							      Devices								   dpt(7D)

NAME
dpt - DPT ServeRAID IV SCSI host bus adapter and RAID adapter driver DESCRIPTION
The dpt driver is a driver for the DPT (Distributed Processing Technology) family of SmartRAID IV SCSI HBA and RAID adapters. The following HBA adapters are supported: PM2024, PM2044UW, PM2044W, PM2124, PM2124W, PM2144UW, and PM2144W. The following RAID adapters are supported: PM3224, PM3224W, PM3334UW, and PM3334W. PRECONFIGURATION
o DPT PM3224 only: Only EPROM 7A and later versions are supported. o DPT PM2024 and PM2124 only: Only EPROM 6D4 and later versions are supported. o Use adapters with SmartROM version 3.B or later versions only. o Be sure that the controller board is installed in a PCI bus-mastering slot. o Disable PCI parity checking if your firmware version is earlier than version 7A, if your system memory is ECC, or if your system does not check parity. Known Problems and Limitations During system boot, a message may be displayed saying a DPT controller driver cannot be installed. This message indicates that the mother- board installed in your system may contain ECC memory or may not check parity. If you see this message is displayed, disable PCI parity checking. Supported Settings o I/O Address: Auto CONFIGURATION
Auto-configuration code determines whether the adapter is present at the configured address and what types of devices are attached to it. The DPT ServeRAID is primarily used as a disk array (system drive) controller. To configure the attached disk arrays, you must configure the controller (using the configuration utilities provided by the hardware manu- facturer) before you boot the Solaris operating environment. You use the configuration utilities to set RAID levels, stripe parameters, cache mechanisms and perform other functions. For more information, see the user manual supplied with your hardware. FILES
/kernel/drv/dpt.conf dpt configuration file /dev/dsk/cndn[s|p]n block device /dev/rdsk/cndn[s|p]n raw device where: cn controller n dn LUN n (0-7) sn UNIX system slice n (0-15) pn fdisk(1M) partition(0) ATTRIBUTES
See attributes(5) for descriptions of the following attributes: +-----------------------------------------------------------+ |ATTRIBUTE TYPE ATTRIBUTE VALUE | |Architecture x86 | +-----------------------------------------------------------+ SEE ALSO
fdisk(1M), attributes(5), cmdk(7D) SunOS 5.11 27 November 2000 dpt(7D)
All times are GMT -4. The time now is 05:05 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy