Sponsored Content
Full Discussion: Disk Array
Top Forums UNIX for Advanced & Expert Users Disk Array Post 302810873 by pmoren on Wednesday 22nd of May 2013 04:04:44 PM
Old 05-22-2013
Disk Array

HI:

I have a DUAL redundant system running in HP-UX 10.20 ( 2 servers)
Both servers share an external SCSI disk array. Both server runs a Data base wich uses the disk array to write the data, and that is the way they share the information.

The way that the servers see the disk array, is like an internal device (/dev), and like an extra hard drive.

Now the disk array has broken, so I have to find a solution, so the servers can countinue to do this process and share the information.

So my questions are:

1) There are SCSI new disk array compatible with my servers HP-UX 10.20?
2) Can I use a disk array that comunicate via network and mounted it as a shared disk?
3) Or what other solution can you recommen me?
4) In other topics, have you ever run HP-UX 10.20 in a virtual machine? Can you tell me wich one ?

It is not possible to upgrade the OS, or to run the Data base as a service, because the application that servers run is not versatil.
 

10 More Discussions You Might Find Interesting

1. UNIX for Dummies Questions & Answers

Disk Array & Clustering

Sorry if this is not the right folder... I come across these terms.. -Disk Array -Clustering What are they? When and how will we use them? Please teach me. Thanks (1 Reply)
Discussion started by: champion
1 Replies

2. Solaris

pinout DB9 to RJ11 of T3 Array Disk?

Hello friends, i have a problem with the pinout of T3 Array Disk cuz i don't know to build this serial cable :( please anybody help me! (1 Reply)
Discussion started by: nikoxve
1 Replies

3. Solaris

storEDGE A5000 disk Array

Do you know how do I make my solaris 8 detect the storEDGE A5000?. I have problem making it recognise, without that I cannot install VxVM. Any ideas? (7 Replies)
Discussion started by: calsum
7 Replies

4. Solaris

A1000 Disk storage array

I am new to the unix world. I have SunBlade 100 and A1000 Disk storage array with 12 Hard drives. I used SCSI card and SCSI cables to connect. When I do the format command,I can see disk storage as one disk instead of 12 disks as below. Could anybody can explain why? What should I do in order... (1 Reply)
Discussion started by: Dulasi
1 Replies

5. UNIX for Advanced & Expert Users

3510 Disk Array Problem

I have a 3510 disk array attached to a T2000 server. The dmesg command shows disk error as follows and is generated a couple of times during the day Aug 18 03:35:51 myserver SUNWscsdMonitor: <rctrl6042> Standard General Event, CHL:2 ID:22 Drive NOTICE: Drive Recovered Error - 5F8E1F... (1 Reply)
Discussion started by: Tirmazi
1 Replies

6. Solaris

Managing disk array on A1000

I would want to ask on what software do i need to configure disk array for StorEdge A1000. (Sun Enterprise 450 - currently installed with SUN Solaris 9.) Is it using RAID Manager 6.22? And is it compatible with SUN Solaris 9 or 10? Thanks in advance for reading or replying my post. (2 Replies)
Discussion started by: beginningDBA
2 Replies

7. Solaris

Disk Array

So I have 2 solaris sun servers one with a disk array with 14 drives which I need to move to the other server. How do I move the disk array configured as a Raid 5 to another server without losing data? So far I know I'll connect the drive, run devfsadm, use format to verify the server see's... (5 Replies)
Discussion started by: Kjons76
5 Replies

8. UNIX for Dummies Questions & Answers

Raid0 array stresses only 1 disk out of 3

Hi there, I've setup a raid0 array of 3 identical disks using : mdadm --create --verbose /dev/md0 --level=stripe --raid-devices=3 /dev/sdb1 /dev/sdc1 /dev/sdd1I'm using dstat to monitor the disk activity : dstat --epoch -D sdb,sdc,sdd --disk-util 30The results show that the stress is not... (8 Replies)
Discussion started by: chebarbudo
8 Replies

9. Filesystems, Disks and Memory

DISK ARRAY PROTECTION SUSPENDED message displayed following disk replacement

Hello, On 4/20/2018, we performed a disk replacement on our IBM 8202 P7 server. After the disk was rebuilt, the SAS Disk Array sissas0 showed a status of degraded. However, the pdisks in the array all show a status of active. We did see a message in errpt. DISK ARRAY PROTECTION SUSPENDED. ... (1 Reply)
Discussion started by: terrya
1 Replies

10. AIX

DISK ARRAY PROTECTION SUSPENDED message following disk replacement

Hello, On 4/20/2018, we performed a disk replacement on our IBM 8202 P7 server. After the disk was rebuilt, the SAS Disk Array sissas0 showed a status of degraded. However, the pdisks in the array all show a status of active. We did see a message in errpt. DISK ARRAY PROTECTION SUSPENDED. ... (3 Replies)
Discussion started by: terrya
3 Replies
TAPSET::SCSI(3stap)													       TAPSET::SCSI(3stap)

NAME
tapset::scsi - systemtap scsi probe points DESCRIPTION
This family of probe points is used to probe the SCSI activities. It contains the following probe points: scsi.ioentry Fires when SCSI mid layer prepares a SCSI request Arguments: disk_major The major number of the disk disk_minor The minor number of the disk device_state The current state of the device. The possible values could be: SDEV_CREATED = 1, /* device created but not added to sysfs * Only internal commands allowed (for inq) */ SDEV_RUNNING = 2, /* device properly configured * All commands allowed */ SDEV_CANCEL = 3, /* beginning to delete device * Only error handler commands allowed */ SDEV_DEL = 4, /* device deleted * no commands allowed */ SDEV_QUIESCE = 5, /* Device quiescent. No block commands * will be accepted, only specials (which * originate in the mid-layer) */ SDEV_OFFLINE = 6, /* Device offlined (by error handling or * user request */ SDEV_BLOCK = 7, /* Device blocked by scsi lld. No scsi * commands from user or midlayer should be issued * to the scsi lld. */ scsi.iodispatching Fires when the SCSI mid layer dispatches a SCSI command to the low level driver Arguments: host_no The host number channel The channel number lun The lun number dev_id The scsi device id device_state The current state of the device. data_direction The data_direction specifies whether this command is from/to the device. The possible values could be: DMA_BIDIRECTIONAL = 0, DMA_TO_DEVICE = 1, DMA_FROM_DEVICE = 2, DMA_NONE = 3, request_buffer The request buffer address req_bufflen The request buffer length scsi.iodone Fires when a SCSI command is done by low level driver and enqueued into the done queue. Arguments: host_no The host number channel The channel number lun The lun number dev_id The scsi device id device_state The current state of the device data_direction The data_direction specifies whether this command is from/to the device. scsi.iocompleted Fires when SCSI mid layer runs the completion processing for block device I/O requests Arguments: host_no The host number channel The channel number lun The lun number dev_id The scsi device id device_state The current state of the device data_direction The data_direction specifies whether this command is from/to the device. goodbytes The bytes completed. SEE ALSO
stap(1), stapprobes(3stap) IBM
TAPSET::SCSI(3stap)
All times are GMT -4. The time now is 10:47 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy