12-10-2012
I would say the controllers you are talking about might be on a disk storage which has normally 2 controllers on it.
Cheers,
This User Gave Thanks to Joseph_TKLee For This Post:
5 More Discussions You Might Find Interesting
1. Solaris
Previously , i remove the disk by
#vxdg -g testdg -k rmdisk testdg02
But i got error when i -k adddisk
bash-2.03# vxdisk list
DEVICE TYPE DISK GROUP STATUS
c0t0d0s2 auto:none - - online invalid
c0t1d0s2 auto:none ... (1 Reply)
Discussion started by: waibabe
1 Replies
2. Linux
Hi,
Am doing an enhancements related to monitoring a Linux disk I/O statistics.
The /proc/diskstats file is used to get the each disk I/O statistics. But, It returns the raw value.
How to calculate the Disk Queue Length and Disk Busy time from the raw values.
Guide me. (1 Reply)
Discussion started by: maruthu
1 Replies
3. Solaris
I have a solaris 10 system configured using NetApp as its storage, and the file systems are already configured as you can see from the example below:
root@moneta # df -h
Filesystem size used avail capacity Mounted on
/dev/md/dsk/d0 9.8G 513M 9.3G 6% /
... (0 Replies)
Discussion started by: fretagi
0 Replies
4. Filesystems, Disks and Memory
Hello,
On 4/20/2018, we performed a disk replacement on our IBM 8202 P7 server. After the disk was rebuilt, the SAS Disk Array sissas0 showed a status of degraded. However, the pdisks in the array all show a status of active.
We did see a message in errpt. DISK ARRAY PROTECTION SUSPENDED.
... (1 Reply)
Discussion started by: terrya
1 Replies
5. AIX
Hello,
On 4/20/2018, we performed a disk replacement on our IBM 8202 P7 server. After the disk was rebuilt, the SAS Disk Array sissas0 showed a status of degraded. However, the pdisks in the array all show a status of active.
We did see a message in errpt. DISK ARRAY PROTECTION SUSPENDED.
... (3 Replies)
Discussion started by: terrya
3 Replies
LEARN ABOUT NETBSD
hptide
HPTIDE(4) BSD Kernel Interfaces Manual HPTIDE(4)
NAME
hptide -- Triones/Highpoint IDE disk controllers driver
SYNOPSIS
hptide* at pci? dev ? function ? flags 0x0000
DESCRIPTION
The hptide driver supports the Triones/Highpoint HPT366, HPT370, HPT370A, HPT372 and HPT374 IDE controllers, and provides the interface with
the hardware for the ata(4) driver.
The 0x0002 flag forces the hptide driver to disable DMA on chipsets for which DMA would normally be enabled. This can be used as a debugging
aid, or to work around problems where the IDE controller is wired up to the system incorrectly.
SEE ALSO
ata(4), atapi(4), intro(4), pci(4), pciide(4), wd(4), wdc(4)
BUGS
The timings used for the PIO and DMA modes for controllers listed above are for a PCI bus running at 30 or 33 MHz. This driver may not work
properly on overclocked systems.
BSD