Operating Systems AIX VIOS FC Mapping/NPIV questions Post 302728927 by kah00na on Thursday 8th of November 2012 05:15:30 PM
Old 11-08-2012
Did you check them when you were at the SMS menus? The LPAR has to be booted far enough along that the virtual fiber cards are started and you should see them connect to the VIO server. When the LPAR is down, the virtual fiber cards are gone and that is why you don't see them on the VIO server side.
 

10 More Discussions You Might Find Interesting

1. AIX

Problem mapping LUN disk from VIOS to the LPAR

Hello guys, It would be so nice of you if someone can provide me with these informations. 1) My SAN group assigned 51G of LUN space to the VIO server.I ran cfgdev to discover the newly added LUN. Unfortunately most of the disks that are in VIO server is 51G. How would I know which is the newly... (3 Replies)
Discussion started by: solaix14
3 Replies

2. AIX

VIOS to lpar Mapping

Hello, I have created mapping of 2 virtual adapters for Lpars using following command: mkvdev -vdev ipanalyzerlv1 -vadapter vhost11 mkvdev -vdev ipanalyzerlv -vadapter vhost13 The above two commands were succesfull but when I want to map the third virtual device to the same Lpar than... (3 Replies)
Discussion started by: Vit0_Corleone
3 Replies

3. AIX

Anyone using NPIV?

Is anyone here using NPIV with AIX? If you are, what type of switch are you connected to? Also, please share some impressions of NPIV over traditional port-to-port LUN assignments. We are looking to move to NPIV and need some convincing argume... I mean information. (2 Replies)
Discussion started by: kah00na
2 Replies

4. AIX

Migrating hdisks from vscsi to NPIV with powerpath

Hi All, I'm preparing to migrate some servers from vscsi to pass-thru NPIV. I am planning to have the SAN team move the exact LUNs from vio1/vio2 to those two VWWN through NPIV. My question is on the partition itself.. right now, let's say I have hdisk0/1/2/3/4 that are part of datavg. They... (2 Replies)
Discussion started by: lapfrank
2 Replies

5. AIX

Vscsi and npiv on same adapter

Hi, I want to change from vscsi to npiv. Is it possible to use both on the same adapter, so we can change the systems one by one, or must we place a second FC adapter in the VIO servers? Thanks, Ronald (2 Replies)
Discussion started by: ronaldm60
2 Replies

6. AIX

Few VIOS questions

Hi, I would like to ask you if you could help me to answer these questions. Please. How to check in vios, size all pv's and to what they are mapped to? How to chech on vios/hmc which PowerVM edition is used? Thank you. (7 Replies)
Discussion started by: phobus
7 Replies

7. AIX

NPIV mapping problem

Hello all I hope someone can help me with this. I have a single LPAR which is supplied a rootvg and datavg disk set from a dual VIO server configuration. I see dual path disks for all the datavg disks but only see one path for the rootvg disks. The client LPAR has the following: fcs0 ... (3 Replies)
Discussion started by: johnf
3 Replies

8. Shell Programming and Scripting

Creating unique mapping from multiple mapping

Hello, I do not know if this is the right title to use. I have a large dictionary database which has the following structure: where a b c d e are in English and p q r s t are in a target language., the two separated by the delimiter =. What I am looking for is a perl script which will take... (5 Replies)
Discussion started by: gimley
5 Replies

9. AIX

NPIV custom WWN

Hi All :) i would like to know if i can customize the WWN of the new VFC (NPIV). Or, if i must move the LPAR on another server with another FCS, i have to change the zoning?? Thanks in advance. Mario ---------- Post updated 09-21-12 at 02:51 AM ---------- Previous update was 09-20-12 at... (1 Reply)
Discussion started by: Zio Bill
1 Replies

10. AIX

VIOS IP address - separate vlan for vios servers ?

Hello, Lets say for simplicity that I do not use any vlan config inside my server - one lpar group use hea physical port1, another group hea physical port2. Physical port1 configured as vlan1 on external switch, physical port2 as vlan2. What is the common practice - should I isolate my vios... (0 Replies)
Discussion started by: vilius
0 Replies
roarvio(7)						System Manager's Manual: RoarAuido						roarvio(7)

NAME
libroar - RoarAudio sound library roarvio - RoarAudio virtual IO layer SYNOPSIS
#include <roaraudio.h> struct roar_vio_calls; DESCRIPTION
The RoarAudio VIO interface is RoarAudio's IO abstraction layer. It provides basic IO functions such as read and write independing on the underlaying IO. For Example can you open a plain or a gziped file via the VIO layer. After a successful open both objects behave the same, libroar takes care about the compression in the gzip case. TUTORIALS
Tutorials can be found in roartutvio(7). IMPORTANT FUNCTIONS
There are several important functions. This is a small list of the most important ones. Opening roar_vio_open_file(3), roar_vio_open_fh(3), roar_vio_open_stdio(3), roar_vio_open_dstr(3), roar_vio_open_proto(3). While there are a lot functions important for opening files the most important one is roar_vio_open_dstr(3). It opens a stream based on URLs that can point to local files or files on remote machines. It also can handle compression and encryption. Closing roar_vio_close(3), roar_vio_shutdown(3) Reading and writing roar_vio_read(3), roar_vio_write(3) Seeking and positioning roar_vio_lseek(3) Non-Blocking and Asyncron IO roar_vio_nonblock(3), roar_vio_sync(3), roar_vio_select(3) Networking and Sockets roar_vio_accept(3) String handling roar_vio_printf(3) BUGS
A lot... SEE ALSO
roar-config(1), roartypes(1), roartutvio(7), RoarAudio(7). RoarAudio May 2011 roarvio(7)
All times are GMT -4. The time now is 03:26 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy