Sponsored Content
Operating Systems HP-UX FAULTY DISK replacement HP rx4640 Post 302644183 by gjk on Monday 21st of May 2012 11:54:15 AM
Old 05-21-2012
Thank you for your help VBE and you are not blind but I don't know the OS version. As i have very limited access to the costumer site only tonight i will be able to find out the OS version and more about the disk. What i have confirmed is that it is a boot disk. With what i know from costumer the system is connected to msl6030 tape library and they do backups of configuration every day. Unfortunately I'm not familiar with diagnose tool but I'll try my best to get as much info as possible and post.
Thank you very very much
 

10 More Discussions You Might Find Interesting

1. Solaris

Disk replacement with svm

I dont even know what raid level this is, but its raid 5 mirrored from the looks of it. I have a failed disk (t12) within this mirror. What is the best way to replace this disk? 2 things concern me, isn't there a command to prepare the disk for a hot swap? and what should i do with the... (3 Replies)
Discussion started by: BG_JrAdmin
3 Replies

2. AIX

Removing Faulty Disk SSA

Hi Experts, I have configured A D40 Array. There is an faulty disk which is not part of an raid volume but shows fault in the diagnostics. pdisk15 U0.1-P1-I1/Q1-W40AA83CC2400D SSA160 Physical Disk Drive ( MB) Is there a way to stop this... (2 Replies)
Discussion started by: vuppala360
2 Replies

3. Solaris

Help with faulty Disk on Sun OS

Hi, Recently i came across a disk that seems to be faulty and need help. I have gathered some information by running below commands and any help on how to solve this will be great. # uname –a SunOS XYZ 5.7 Generic_106541-16 sun4u sparc SUNW,Ultra-4 #df -k Filesystem kbytes used... (3 Replies)
Discussion started by: phanidhar6039
3 Replies

4. HP-UX

Remove Faulty disk from HP-UX LVM VG

Requirement to remove a faulty mirrored disk from hp-ux LVM <root@pdwp1s>/etc # vgdisplay -v /dev/vg00 vgdisplay: Warning: couldn't query physical volume "/dev/dsk/c2t0d0": The specified path does not correspond to physical volume attached to this volume group vgdisplay: Warning: couldn't... (9 Replies)
Discussion started by: Shirishlnx
9 Replies

5. HP-UX

Remove faulty disk LV from VG

Hi, Have mirrored the primary disk to 3 . Server and OS: # uname -a HP-UX pdwp1s B.11.11 U 9000/800 118434630 unlimited-user license # model 9000/800/L3000-7x # strings /etc/lvmtab /dev/vg00 +F@< /dev/dsk/c1t2d0 /dev/dsk/c2t2d0 /dev/dsk/c2t0d0 But now I have only 1 disk... (5 Replies)
Discussion started by: Shirishlnx
5 Replies

6. Solaris

[solved] How to blink faulty disk in Solaris hardware?

Hi Guys, One of two disks in my solaris machine has failed, the name is disk0, this is SUN physical sparc machine But I work remotely, so people working near that physical server are not that technical, so from OS command prompt can run some command to bink faulty disk at front panel of Server.... (9 Replies)
Discussion started by: manalisharmabe
9 Replies

7. AIX

Disk replacement on SharedVG.

Hi, One of my disk is in 'disk missing state'. It is a sharedVG and cluster nodes. The errpt keeps reporting stale partition error. lvs are in open/stale state. In this sceanario is replacing the disk the best practice? When i do a lsdev the disk is labelled as below. hdisk3 Available ... (2 Replies)
Discussion started by: ElizabethPJ
2 Replies

8. Filesystems, Disks and Memory

DISK ARRAY PROTECTION SUSPENDED message displayed following disk replacement

Hello, On 4/20/2018, we performed a disk replacement on our IBM 8202 P7 server. After the disk was rebuilt, the SAS Disk Array sissas0 showed a status of degraded. However, the pdisks in the array all show a status of active. We did see a message in errpt. DISK ARRAY PROTECTION SUSPENDED. ... (1 Reply)
Discussion started by: terrya
1 Replies

9. AIX

DISK ARRAY PROTECTION SUSPENDED message following disk replacement

Hello, On 4/20/2018, we performed a disk replacement on our IBM 8202 P7 server. After the disk was rebuilt, the SAS Disk Array sissas0 showed a status of degraded. However, the pdisks in the array all show a status of active. We did see a message in errpt. DISK ARRAY PROTECTION SUSPENDED. ... (3 Replies)
Discussion started by: terrya
3 Replies

10. UNIX for Beginners Questions & Answers

Show faulty shows PS1 faulty

I plugged both power cables in both power supply. When I unplugged each power cable one by one, the SPARC T4-1 machine keep running. However, show faulty command shows below message. (I have also attached the picture of both power supply) -> show faulty Target ... (1 Reply)
Discussion started by: z_haseeb
1 Replies
bootconf(4)						     Kernel Interfaces Manual						       bootconf(4)

NAME
bootconf - boot device configuration table DESCRIPTION
The file contains the address and disk layout type of the system's boot devices or lif volumes. It is used by the and HP-UX kernel control scripts (fileset to determine how and where to update the initial boot loader. Normally the kernel's script queries the system's hardware and creates the file. In rare cases when either the system configuration cannot be automatically determined or additional and/or alternate boot devices should be automatically updated, the administrator must edit the file manually. There is one line in the file for each boot device. Each line contains the following blank-separated fields in the order shown: disk type A flag indicating how the file system(s) on the disk are laid out. The flag must be one of the following: Indicates that the root disk is in LVM or VERITAS Volume Manager (VxVM) format. If LVM or VxVM mirrors are used, then each of the "mirrors" must have its own line in the file. Indicates that the root disk is in the "whole disk" format with no partitions, but boot and swap space are reserved outside the file system. device file The absolute path of the device special file that accesses the physical device where the boot area is located. For LVM root disks, the device special file is the physical volume(s) returned by the command. For "whole disks" this is the device file that references the entire disk. Blank lines are permitted. Any line beginning with a is considered to be a comment. DIAGNOSTICS
The Software Distributor log file contains diagnostic messages under the fileset if the file is incorrect. Most of the messages are self- explanatory; a few warrant additional explanation: If there are no other messages about the file is probably empty. Otherwise, the file is not in the proper format, and the other messages will explain what the problem is. The specified device file does not point to a disk where there is a lif which contains the file Some character other than or is in the first field of a line. As of release 10.0, the boot areas in must all be on the same type of disk layout. There are characters after the device file specification. EXAMPLES
The boot area is on an LVM root disk: l /dev/disk/disk7_p2 The boot area is on a whole disk layout: w /dev/disk/disk7 WARNINGS
All of the boot devices in the file must have the same disk layout. AUTHOR
was developed by the Hewlett-Packard Company. FILES
SEE ALSO
mediainit(1), hpux(1M), hpux.efi(1M), mkboot(1M), vgdisplay(1M), lif(4), intro(7). documentation. bootconf(4)
All times are GMT -4. The time now is 04:19 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.