hi,

map the disks to the lpar(s), and create the concurrent vg there

local vio-server disks, or external storage?




I would create the vg on one lpar, create all the filesystems etc. switch to concurrent mode
then varyoff and import on the other lpar, using the same vg major number

just ask if you need more details
This User Gave Thanks to funksen For This Post:
 

10 More Discussions You Might Find Interesting

1. AIX

Help urgent : vio server - add extral disk on virtual lpar

Hi, I define 2 new LV on the vio server and run a cfgmgr on the partition and see my 2 new hdisk (hdisk6 and hdisk7). I extend my vg vg000 (on the partition) and add the 2 hdisks. I had a filesystem on the vg000 and when I added the disk I would like to increase the filesystem. But I cannot do a... (0 Replies)
Discussion started by: touny
0 Replies

2. AIX

LPAR and vio disk mapping

We have a frame the uses 2 vios that assign disk storage to LPAR's. We have a LPAr with multiple disk and I want to know how do I tell which vio is serving the disk. For example the LPAr has hdisk 0, 1, 2, 3 all the same size. I want to know which vio is serving hdisk0, 1. (4 Replies)
Discussion started by: daveisme
4 Replies

3. AIX

vio server and vio client

Hi, I want to know wheather partition size for installation of vio client can be specified on vio server example If I am installing vio server on blade with 2*300gb hard disk,after that I want to create 2 vio client (AIX Operating system) wheather I can specify hard disk size while... (1 Reply)
Discussion started by: manoj.solaris
1 Replies

4. AIX

VIO Backing Disk LPAR how to find which one ?

hello Folks, my vio: $ lsmap -all SVSA Physloc Client Partition ID --------------- -------------------------------------------- ------------------ vhost0 U9117.MMA.6534BE4-V2-C11 0x00000003 VTD ... (0 Replies)
Discussion started by: filosophizer
0 Replies

5. AIX

LPAR and AIX VIO Disk Mappring for Linux Clients

VIO Server is managing both AIX Clients and Linux Clients. For AIX Clients, we could do a disk mapping from slot numbers to VIO and also uname -L to determine the lparid and serial number frame its running on. From a Linux Client, How do I know which IBM frame its running on? Any command to... (4 Replies)
Discussion started by: rpangulu
4 Replies

6. AIX

vio server's rootvg disk migratepv

Hi I need to do the migratepv for the rootvg disks of the vio servers ? The current rootvg disks are on DMX3 storage and the new disks will be given from VMAX. Our setup is dual vio servers with multipathing to the vio clients. What is the command to do the migratepv for the vio rootvg disks... (5 Replies)
Discussion started by: newtoaixos
5 Replies

7. AIX

vio server ethernet to vio client ethernet(concepts confusing)

Hi In the vio server when I do # lsattr -El hdisk*, I get a PVID. The same PVID is also seen when I put the lspv command on the vio client partition. This way Im able to confirm the lun using the PVID. Similarly how does the vio client partition gets the virtual ethernet scsi client adapter... (1 Reply)
Discussion started by: newtoaixos
1 Replies

8. AIX

Mirroring vio server

Hi, I would like to know installing vio server on local disk and mirroring rootvg, if I am creating AIX VIO CLIENT(lpar), and any of single local hard disk failuare. will it affect lpars? will lpars able to boot. what needs to be done? (1 Reply)
Discussion started by: manoj.solaris
1 Replies

9. AIX

VIO and LPAR disk/fcs communications

:wall::wall::wall: 1. I have created an LPAR in the HMC. 2. I have allocated the storage from an Hitachi AMS2500 and assigned it to the host group. 3. I have zoned the LPAR and Storage on a Brocade 5100. (The zone sees the AMS) Next I activated the LPAR in the HMC, SMS mode for the mksysb... (3 Replies)
Discussion started by: Dallasguy7
3 Replies

10. AIX

VIO Server

Hi, I am facing an issue in vio server. When I run bosboot -ad /dev/hdisk0 I am getting an error trustchk: Verification of attributes failed: /usr/sbin/bootinfo : accessauths regards, vjm Please use code tags next time for your code and data. (8 Replies)
Discussion started by: vjm
8 Replies
vgchgid(1M)															       vgchgid(1M)

NAME
vgchgid - modify the Volume Group ID (VGID) on a given set of physical devices SYNOPSIS
PhysicalVolumePath [PhysicalVolumePath] ... DESCRIPTION
The command is designed to change the LVM Volume Group ID (VGID) on a supplied set of disks. will work with any type of storage, but it is primarily targeted at disk arrays that are able to create "snapshots" or "clones" of mirrored LUNs. accepts a set of raw physical devices and ensures that they all belong to the same volume group, before altering the VGID (see section). The same VGID is set on all the disks and it should be noted that in cases of multi-PV volume groups, all the physical volumes should be supplied in a single invocation of the command. Options recognizes the following options and arguments: PhysicalVolumePath The raw devices path name of a physical volume. Background Some storage subsystems have a feature which allows a user to split off a set of mirror copies of physical storage (termed or just as LVM splits off logical volumes with the command. As the result of the "split," the split-off devices will have the same VGID as the original disks. is needed to modify the VGID on the BCV devices. Once the VGID has been altered, the BCV disks can be imported into a new volume group by using WARNINGS
Once the VGID has been changed, the original VGID is lost until a disk device is re-mirrored with the original devices. If is used on a subset of disk devices (for example, two out of four disk devices), the two groups of disk devices would not be able to be imported into the same volume group since they have different VGIDs on them. The solution is to re-mirror all four of the disk devices and re-run on all four BCV devices at the same time, and then use to import them into the same new volume group. If a disk is newly added to an existing volume group and no subsequent LVM operations has been performed to alter the structures (in other words, operations which perform an automated vgcfgbackup(1M)); then it is possible a subsequent will fail. It will report that the disk does not belong to the volume group. This may be overcome by performing a structure changing operation on the volume group (for example, using It is the system administrator's responsibility to make sure that the devices provided in the command line are all Business Copy volumes of the existing standard physical volumes and are in the ready state and writable. Mixing the standard and BC volumes in the same volume group can cause data corruption. RETURN VALUE
returns the following values: 0 VGID was modified with no error 1 VGID was not modified EXAMPLES
An example showing how might be used: 1. The system administrator uses the following commands to create the Business Continuity (BCV or BC) copy: 1) For EMC Symmetrix disks, the commands are and 2) For XP disk array, the commands are and Three BCV disks are created. 2. Change the VGID on the BCV disks. 3. Make a new volume group using the BCV disks. This step can be skipped as the group file will be created automatically. If the file is manually created it will have different major and minor numbers (see lvm(7)). 4. Import the BCV disks into the new volume group. 5. Activate the new volume group. 6. Backup the new volume group's LVM data structure. 7. Mount the associated logical volumes. SEE ALSO
vgimport(1M), vgscan(1M), vgcfgbackup(1M). vgchgid(1M)
All times are GMT -4. The time now is 02:39 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy