No this is another set of server on which am testing the clone behaviors ..
Here what have did
# OS data alread in 1 mirrored state
# HAVE mirrored it to one more disk
# AND removed the third disk
# Then have run below script --Shirish
Last edited by methyl; 02-09-2012 at 10:56 AM..
Reason: please use code tags
Hi Experts,
I have configured A D40 Array. There is an faulty disk which is not part of an raid volume but shows fault in the diagnostics.
pdisk15 U0.1-P1-I1/Q1-W40AA83CC2400D
SSA160 Physical Disk Drive ( MB)
Is there a way to stop this... (2 Replies)
We have a filesystem which contains 8 hard disks but i am facing disk I/O issue becuase data is not spreading across all the disks.Is there any way i can check how data is spreading and any parameter we need to change to spread ata across all disks.
OS--AIX 5.3 (1 Reply)
Hi,
Recently i came across a disk that seems to be faulty and need help. I have gathered some information by running below commands and any help on how to solve this will be great.
# uname –a
SunOS XYZ 5.7 Generic_106541-16 sun4u sparc SUNW,Ultra-4
#df -k
Filesystem kbytes used... (3 Replies)
Hi,
Have mirrored the primary disk to 3 .
Server and OS:
# uname -a
HP-UX pdwp1s B.11.11 U 9000/800 118434630 unlimited-user license
# model
9000/800/L3000-7x
# strings /etc/lvmtab
/dev/vg00
+F@<
/dev/dsk/c1t2d0
/dev/dsk/c2t2d0
/dev/dsk/c2t0d0
But now I have only 1 disk... (5 Replies)
Hello,
I'm new to this forum and as you will see from my question I'm new to UNIX as well.
One of our costumers has HP rx4640 running on UNIX with two 300GB hot-swappable disks that are mirrored. They reported to us that one of the disks is faulty and they want us to take care of it. Below is... (16 Replies)
Hi Guys,
One of two disks in my solaris machine has failed, the name is disk0, this is SUN physical sparc machine
But I work remotely, so people working near that physical server are not that technical, so from OS command prompt can run some command to bink faulty disk at front panel of Server.... (9 Replies)
Hi guys,
I would like to ask your opinion about my theory, how to fix my broken LVM without risking any data loss.
I use Archlinux at home. I just love this distro, even it gives me a lots of work (particularly after system updates).
Basic system spec:
AMD FX(tm)-6100 Six-Core Processor... (1 Reply)
Scenario1:
VG00 lvm,not mirrored,2 disk of 36GB vg size
VG00 size is under 30G.
Is possible to remove a disk of 36GB and replace "on fly"
with a disk of 300GB on VG00?
Thanks (6 Replies)
I plugged both power cables in both power supply. When I unplugged each power cable one by one, the SPARC T4-1 machine keep running. However, show faulty command shows below message. (I have also attached the picture of both power supply)
-> show faulty
Target ... (1 Reply)
Discussion started by: z_haseeb
1 Replies
LEARN ABOUT PHP
pvck
PVCK(8) System Manager's Manual PVCK(8)NAME
pvck - check physical volume metadata
SYNOPSIS
pvck [-d|--debug] [-h|--help] [-v|--verbose] [--labelsector] PhysicalVolume [PhysicalVolume...]
DESCRIPTION
pvck checks physical volume LVM metadata for consistency.
OPTIONS
See lvm for common options.
--labelsector sector
By default, 4 sectors of PhysicalVolume are scanned for an LVM label, starting at sector 0. This parameter allows you to specify a
different starting sector for the scan and is useful for recovery situations. For example, suppose the partition table is corrupted
or lost on /dev/sda, but you suspect there was an LVM partition at approximately 100 MB. This area of the disk may be scanned by
using the --labelsector parameter with a value of 204800 (100 * 1024 * 1024 / 512 = 204800):
pvck --labelsector 204800 /dev/sda
Note that a script can be used with --labelsector to automate the process of finding LVM labels.
SEE ALSO lvm(8), pvcreate(8), pvscan(8)vgck(8)Sistina Software UK LVM TOOLS 2.02.95(2) (2012-03-06) PVCK(8)