Operating Systems HP-UX HP-UX server cloning Post 302596448 by Peasant on Tuesday 7th of February 2012 11:47:33 AM
Old 02-07-2012
Does the new (target) machine has FC ?

If it does :
Make a vgexport of SAN volume group (preview -p -m -s, it will not export).
Save the map file under /root filesystem (on OS source disks).
Take IGNITE backup of entire OS.
Restore IGNITE backup to new machine.
Make local disk setup (pvcreate, vgcreate etc.)
Depresent the SAN disks from source machine
Present same SAN disks to the new machine (verify you see all LUNS correctly)
Do a vgimport with map file (with neccesary steps taken before like mknod, check HPUX LVM.)
Use cp / rsync to copy the data from SAN disks to local disks.
Mount the local disk layout and check service.
This User Gave Thanks to Peasant For This Post:
 

9 More Discussions You Might Find Interesting

1. UNIX for Dummies Questions & Answers

Aix Cloning

Is there anyone out there who knows anything about aix cloning? I would be very grateful for any information at all. Thanking you in advance :) (4 Replies)
Discussion started by: annette
4 Replies

2. Filesystems, Disks and Memory

Unix Cloning

I'm looking for software that can clone Unix Partitions. (2 Replies)
Discussion started by: jimv2502893
2 Replies

3. SCO

Disk cloning

Hello everybody, :confused: I have to change the system disk on an old PC running SCO 5.0.5. The disk is up and running, this is a preventive action. My experience on UNIX is very limited and I look for the easyest solution to clone this unit. Is it possible with commands or through a clone... (2 Replies)
Discussion started by: mhachez
2 Replies

4. UNIX for Dummies Questions & Answers

HP10.20 Cloning

Good day all. So, here's the situation. I have (7x) B180L VISUALIZE WORKSTATION's with Transtec 5100 RAID (RAID 5, 9.1 GB HDD's) towers running of UNIX HP10.20. It's time to replace the RAID's with new ones, them being Fibrenetix FX606 5 bay SATA RAID, 5 bay SATA-SCSI desktop RAID including 80Gb... (1 Reply)
Discussion started by: Tony_dw
1 Replies

5. Red Hat

cloning a server

I wish to clone a RedHat EL5 server. What's the easiest way to do this? Thanks :) (4 Replies)
Discussion started by: wazzu62
4 Replies

6. Shell Programming and Scripting

Cloning

Hi, Is there disadvantages if we do AIX Serevr cloning to the new AIX server. Thanks in advance (0 Replies)
Discussion started by: kmsekhar
0 Replies

7. AIX

AIX Server Cloning

Hi, Is there disadvantages if we do AIX Serevr cloning to the new AIX server. Thanks in advance (2 Replies)
Discussion started by: kmsekhar
2 Replies

8. Ubuntu

dd cloning of whole disk

I am using 'dd' to clone an entire hard drive which only has Ubuntu 11.10 and some data with no special options. The disks are both 1Tb, However, I did re-partition the target disk with gparted successfully. The new partions are not the same size as the source disk. When starting 'dd' no partitions... (24 Replies)
Discussion started by: Royalist
24 Replies

9. Linux

Disk cloning ?

Dear All I needed to clone my disk to another hard drive . I did it as the following : #dd if=/dev/sdb of=/dev/sdc But after a while, the procedure ended with the "writing to /dev/sdc input/output error" message. Can you please let me know how can I overcome this as the fdisk now returns as "... (1 Reply)
Discussion started by: hadimotamedi
1 Replies
vgchgid(1M)															       vgchgid(1M)

NAME
vgchgid - modify the Volume Group ID (VGID) on a given set of physical devices SYNOPSIS
PhysicalVolumePath [PhysicalVolumePath] ... DESCRIPTION
The command is designed to change the LVM Volume Group ID (VGID) on a supplied set of disks. will work with any type of storage, but it is primarily targeted at disk arrays that are able to create "snapshots" or "clones" of mirrored LUNs. accepts a set of raw physical devices and ensures that they all belong to the same volume group, before altering the VGID (see section). The same VGID is set on all the disks and it should be noted that in cases of multi-PV volume groups, all the physical volumes should be supplied in a single invocation of the command. Options recognizes the following options and arguments: PhysicalVolumePath The raw devices path name of a physical volume. Background Some storage subsystems have a feature which allows a user to split off a set of mirror copies of physical storage (termed or just as LVM splits off logical volumes with the command. As the result of the "split," the split-off devices will have the same VGID as the original disks. is needed to modify the VGID on the BCV devices. Once the VGID has been altered, the BCV disks can be imported into a new volume group by using WARNINGS
Once the VGID has been changed, the original VGID is lost until a disk device is re-mirrored with the original devices. If is used on a subset of disk devices (for example, two out of four disk devices), the two groups of disk devices would not be able to be imported into the same volume group since they have different VGIDs on them. The solution is to re-mirror all four of the disk devices and re-run on all four BCV devices at the same time, and then use to import them into the same new volume group. If a disk is newly added to an existing volume group and no subsequent LVM operations has been performed to alter the structures (in other words, operations which perform an automated vgcfgbackup(1M)); then it is possible a subsequent will fail. It will report that the disk does not belong to the volume group. This may be overcome by performing a structure changing operation on the volume group (for example, using It is the system administrator's responsibility to make sure that the devices provided in the command line are all Business Copy volumes of the existing standard physical volumes and are in the ready state and writable. Mixing the standard and BC volumes in the same volume group can cause data corruption. RETURN VALUE
returns the following values: 0 VGID was modified with no error 1 VGID was not modified EXAMPLES
An example showing how might be used: 1. The system administrator uses the following commands to create the Business Continuity (BCV or BC) copy: 1) For EMC Symmetrix disks, the commands are and 2) For XP disk array, the commands are and Three BCV disks are created. 2. Change the VGID on the BCV disks. 3. Make a new volume group using the BCV disks. This step can be skipped as the group file will be created automatically. If the file is manually created it will have different major and minor numbers (see lvm(7)). 4. Import the BCV disks into the new volume group. 5. Activate the new volume group. 6. Backup the new volume group's LVM data structure. 7. Mount the associated logical volumes. SEE ALSO
vgimport(1M), vgscan(1M), vgcfgbackup(1M). vgchgid(1M)
All times are GMT -4. The time now is 06:45 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy