Sponsored Content
Full Discussion: transport errors in iostat
Top Forums UNIX for Dummies Questions & Answers transport errors in iostat Post 302592963 by dyavuzy1 on Wednesday 25th of January 2012 10:18:00 AM
Old 01-25-2012
yes, both disks are mirrored, metareplace was invoked and problematic disk was resycned from its sub mirror..

Metastat does not return any message pointing disk need any maintenance process..but there is still some hard and transport errors on it, these errors are not incremented though..
 

10 More Discussions You Might Find Interesting

1. Solaris

PLOGI failed state=Packet Transport error

Someone who can help me. the following error occur, what does it mean, and any possible solution you can give.thanks syslog: fp: NOTICE: fp(2): PLOGI to d5900 failed state=Packet Transport error , reason=No Connection (Database) $cat /var/adm/messages Nov 3 05:16:21 vfaus279 fp: ... (7 Replies)
Discussion started by: o_m_g
7 Replies

2. Shell Programming and Scripting

Transport to another server within a script.

I'm not sure how to phrase this... We currently have a server that we have to load a special kind of file onto, to do this we have a script that someone on my team wrote years ago called emm <file>. We recently added another server to our system, so every file that's added on one has to be added... (2 Replies)
Discussion started by: DeCoTwc
2 Replies

3. Solaris

iostat -nE with Hard Errors

iostat -nE returns the followings I want to know what is happening to my StorEDGE A1000? Can someone help me? It is a critical device. (1 Reply)
Discussion started by: nickychung
1 Replies

4. UNIX for Advanced & Expert Users

Transport Error

Dear Friends, I am using Solaris 10 on Sun Sparc T5120 with 4 HDD(Raid).I am getting transport error in one of my mirrored HDD c1t2d0. Below is a screen shot. I have replaced the HDD with new one but still the same. Any one can help???? c1t2d0 Soft Errors: 0 Hard Errors: 0... (1 Reply)
Discussion started by: solaris5.10
1 Replies

5. Solaris

SC3.2 issue - cluster transport configuration not right - resulting fail

I am trying to set up a two host cluster. trouble is with the cluster transport configuration. i'm using e1000g2 and g3 for the cluster transport. global0 and global1 are my two nodes, and I am running the scinstall from global1. i think i should be expecting, is this: The following... (19 Replies)
Discussion started by: frustin
19 Replies

6. Solaris

What is the difference between softerrors,harderrors,transport errors?

what is the difference between softerrors,harderrors,transport errors? (3 Replies)
Discussion started by: tv.praveenkumar
3 Replies

7. Solaris

iostat -En errors

I all, I would like to know what are the causes of : -soft error -harderror -transport error and how to avoid and repare them. I got the iostat out put below: atng-mm01% iostat -En | grep -i hard c0t0d0 Soft Errors: 1 Hard Errors: 0 Transport Errors: 0 c0t0d1 ... (3 Replies)
Discussion started by: zaza
3 Replies

8. Programming

Problem transport endpoint is not connected

i've made a simple program that change a string from lowercase to uppercase and from uppercase to lowercase. Server works until start client, after client run server give this error: "recv server fallita: Transport endpoint is not connected" why? i think that stream closed too soon or not? below... (1 Reply)
Discussion started by: tafazzi87
1 Replies

9. Solaris

getpeername: Transport endpoint is not connected

Hi Folks, I am getting the following error in /var/adm/messages. Can any one help me out on this? ZXXXXXA:/# tail /var/adm/messages Oct 26 00:13:04 ZXXXXXA ftpd: setsockopt SO_KEEPALIVE Invalid argument Oct 26 00:13:04 ZXXXXXA ftpd: setsockopt (SO_OOBINLINE): Invalid argument Oct 26... (3 Replies)
Discussion started by: vivek.goel.piet
3 Replies

10. Solaris

Sense key unit attention & iostat hardware and transport errors on SAN disks

Hello, I'm trying to get to the bottom of SAN disk errors we've been seeing. Server is Sun Fire X4270 M2 running Solaris 10 8/11 u10 X86 since April 2012. SAN HBAs are SG-PCIE2FC-QF8-Z-Sun-branded Qlogic. SAN storage system is Hitachi VSP. We have 32 LUNs in use and another 8 LUNs not brought... (4 Replies)
Discussion started by: TKD
4 Replies
vgchgid(1M)															       vgchgid(1M)

NAME
vgchgid - modify the Volume Group ID (VGID) on a given set of physical devices SYNOPSIS
PhysicalVolumePath [PhysicalVolumePath] ... DESCRIPTION
The command is designed to change the LVM Volume Group ID (VGID) on a supplied set of disks. will work with any type of storage, but it is primarily targeted at disk arrays that are able to create "snapshots" or "clones" of mirrored LUNs. accepts a set of raw physical devices and ensures that they all belong to the same volume group, before altering the VGID (see section). The same VGID is set on all the disks and it should be noted that in cases of multi-PV volume groups, all the physical volumes should be supplied in a single invocation of the command. Options recognizes the following options and arguments: PhysicalVolumePath The raw devices path name of a physical volume. Background Some storage subsystems have a feature which allows a user to split off a set of mirror copies of physical storage (termed or just as LVM splits off logical volumes with the command. As the result of the "split," the split-off devices will have the same VGID as the original disks. is needed to modify the VGID on the BCV devices. Once the VGID has been altered, the BCV disks can be imported into a new volume group by using WARNINGS
Once the VGID has been changed, the original VGID is lost until a disk device is re-mirrored with the original devices. If is used on a subset of disk devices (for example, two out of four disk devices), the two groups of disk devices would not be able to be imported into the same volume group since they have different VGIDs on them. The solution is to re-mirror all four of the disk devices and re-run on all four BCV devices at the same time, and then use to import them into the same new volume group. If a disk is newly added to an existing volume group and no subsequent LVM operations has been performed to alter the structures (in other words, operations which perform an automated vgcfgbackup(1M)); then it is possible a subsequent will fail. It will report that the disk does not belong to the volume group. This may be overcome by performing a structure changing operation on the volume group (for example, using It is the system administrator's responsibility to make sure that the devices provided in the command line are all Business Copy volumes of the existing standard physical volumes and are in the ready state and writable. Mixing the standard and BC volumes in the same volume group can cause data corruption. RETURN VALUE
returns the following values: 0 VGID was modified with no error 1 VGID was not modified EXAMPLES
An example showing how might be used: 1. The system administrator uses the following commands to create the Business Continuity (BCV or BC) copy: 1) For EMC Symmetrix disks, the commands are and 2) For XP disk array, the commands are and Three BCV disks are created. 2. Change the VGID on the BCV disks. 3. Make a new volume group using the BCV disks. This step can be skipped as the group file will be created automatically. If the file is manually created it will have different major and minor numbers (see lvm(7)). 4. Import the BCV disks into the new volume group. 5. Activate the new volume group. 6. Backup the new volume group's LVM data structure. 7. Mount the associated logical volumes. SEE ALSO
vgimport(1M), vgscan(1M), vgcfgbackup(1M). vgchgid(1M)
All times are GMT -4. The time now is 03:50 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy