12-05-2011
try to change bs to 8MB and see if this did not improve write /read performance.
Those are local disks, san attached or VIO?
10 More Discussions You Might Find Interesting
1. Filesystems, Disks and Memory
Hi all!
Working on Oracle v8.1.7.0.0 with OS as Suse v8.0 Linux.
I had created LVM,linked raw devices to LVM as below:
# for binding raw devices
raw /dev/raw/raw1 /dev/oracle/sam_raw_system_251m
raw /dev/raw/raw2 /dev/oracle/sam_raw_users_26m
raw /dev/raw/raw3... (2 Replies)
Discussion started by: Amitstora
2 Replies
2. AIX
Hy
I have several logical volumes that are turned into raw devices used by Informix DB. I would like to add some more.
In /dev directory i see logical volumes as block files: lv_name1, lv_name2 ...
and
i see raw devices defined as character files:
rlv_name1, rlv_name2 ...
As i see,... (5 Replies)
Discussion started by: veccinho
5 Replies
3. UNIX for Advanced & Expert Users
Hello group,
Is it possible to use partition on a disk as a raw device? I have a LUN on a SAN which I would like to partition and use those partitions as raw device.
If it is feasable, how do I bind them to a device?
For example, say sdd has 3 partitions on it, sdd1, sdd2 and sdd3. Can I... (1 Reply)
Discussion started by: bfay
1 Replies
4. Solaris
Hi All ,
I would like to know the procedure for increasing shared volume space in sun cluster .
Currently the configuration is like these .
Main stripe
oradb1/d91 2 1 /dev/did/rdsk/d35s0 1 /dev/did/rdsk/d36s0 =Total 49 Gb
oradb1/d94 -p oradb1/d91 -o 88080480 -b 14680064 ==Total 7 GB... (4 Replies)
Discussion started by: sahil_shine
4 Replies
5. Red Hat
Hi,
I had a doubt regarding device mapper notations and their corresponding LVM volumes.
I have configured a volume group with two logical volumes in it as root and swap.
The entries in the /etc/fstab file show the dm notations namely,
/dev/mapper/VolGroup00-LogVol01... (2 Replies)
Discussion started by: kanna_geekworkz
2 Replies
6. Solaris
Hi,
I am using Sun Solaris 10 (Sparc 64 bit),
I have a meta device /dev/dsk/emcpower26a mounting on /u01. I want to make this metadeice as raw device.
Need solaris command to remove file system and make it as raw device ?.
Is there any solaris command to check raw devices ?.
Thanks (1 Reply)
Discussion started by: zeeshan047
1 Replies
7. Solaris
Hi,
I need to create 4 zones.
I have an array with a RAID5 volume. I have exported 4 LUNS from the array. Now my host see the 4 LUNS as raw devices.
I am partitioning each LUN using format then mounting each slice on the global zone. Then I am using each slice as a file system for my non... (3 Replies)
Discussion started by: general_lee
3 Replies
8. Solaris
Hi,
I'm trying to find out how to see used space on RAW device.
I tried with prtvtoc -f RAWdevice but for 3 different device I'm getting the same FREE_SIZE which look a bit impossible.
root@zg8cscfb1> prtvtoc -f /dev/md/redodg/rdsk/d300
FREE_START=0 FREE_SIZE=20352 FREE_COUNT=1 FREE_PART=... (2 Replies)
Discussion started by: MarioT
2 Replies
9. UNIX for Dummies Questions & Answers
HI,
I want to start Oracle on UNIX machine, now the , it is failing to startup because it cannot identify a raw device. Actually machine was rebooted and now we need to mount the devices, but i just want to know the command/way to mount or rather start/init a raw device. Please let me know. (2 Replies)
Discussion started by: Onkar Banerjee
2 Replies
10. Red Hat
Hi,
How to find the raw device/multipath details of the LUN used by the diskgroups of the database.
file system type -- ASM
Oracle -- 11.2.0.3.0
OS -- Linux
This is RAC database.
Regards,
Maddy (2 Replies)
Discussion started by: Maddy123
2 Replies
vgchgid(1M) vgchgid(1M)
NAME
vgchgid - modify the Volume Group ID (VGID) on a given set of physical devices
SYNOPSIS
PhysicalVolumePath [PhysicalVolumePath] ...
DESCRIPTION
The command is designed to change the LVM Volume Group ID (VGID) on a supplied set of disks. will work with any type of storage, but it is
primarily targeted at disk arrays that are able to create "snapshots" or "clones" of mirrored LUNs. accepts a set of raw physical devices
and ensures that they all belong to the same volume group, before altering the VGID (see section).
The same VGID is set on all the disks and it should be noted that in cases of multi-PV volume groups, all the physical volumes should be
supplied in a single invocation of the command.
Options
recognizes the following options and arguments:
PhysicalVolumePath The raw devices path name of a physical volume.
Background
Some storage subsystems have a feature which allows a user to split off a set of mirror copies of physical storage (termed or just as LVM
splits off logical volumes with the command. As the result of the "split," the split-off devices will have the same VGID as the original
disks. is needed to modify the VGID on the BCV devices. Once the VGID has been altered, the BCV disks can be imported into a new volume
group by using
WARNINGS
Once the VGID has been changed, the original VGID is lost until a disk device is re-mirrored with the original devices. If is used on a
subset of disk devices (for example, two out of four disk devices), the two groups of disk devices would not be able to be imported into
the same volume group since they have different VGIDs on them. The solution is to re-mirror all four of the disk devices and re-run on all
four BCV devices at the same time, and then use to import them into the same new volume group.
If a disk is newly added to an existing volume group and no subsequent LVM operations has been performed to alter the structures (in other
words, operations which perform an automated vgcfgbackup(1M)); then it is possible a subsequent will fail. It will report that the disk
does not belong to the volume group. This may be overcome by performing a structure changing operation on the volume group (for example,
using
It is the system administrator's responsibility to make sure that the devices provided in the command line are all Business Copy volumes of
the existing standard physical volumes and are in the ready state and writable. Mixing the standard and BC volumes in the same volume
group can cause data corruption.
RETURN VALUE
returns the following values:
0 VGID was modified with no error
1 VGID was not modified
EXAMPLES
An example showing how might be used:
1. The system administrator uses the following commands to create the Business Continuity (BCV or BC) copy:
1) For EMC Symmetrix disks, the commands are and
2) For XP disk array, the commands are and
Three BCV disks are created.
2. Change the VGID on the BCV disks.
3. Make a new volume group using the BCV disks.
This step can be skipped as the group file will be created automatically. If the file is manually created it will have different major
and minor numbers (see lvm(7)).
4. Import the BCV disks into the new volume group.
5. Activate the new volume group.
6. Backup the new volume group's LVM data structure.
7. Mount the associated logical volumes.
SEE ALSO
vgimport(1M), vgscan(1M), vgcfgbackup(1M).