Sponsored Content
Operating Systems Solaris Do I need a pool before I can mirror my disks? Post 302556324 by CarlosP on Sunday 18th of September 2011 02:53:15 AM
Old 09-18-2011
This is the image. I forgot to attach it on the previous post. Sorry.
Do I need a pool before I can mirror my disks?-diskjpg
 

9 More Discussions You Might Find Interesting

1. UNIX for Advanced & Expert Users

sync mirror disks

Does anyone know how to force these rogue logical volumes to mirror to there respective disks? DISK:Logical Volumes 03:cw_p05,cw_p01_01,cw_p01_02,lv00 09:cw_p05,cw_p01_01,cw_p01_02 04:cw_p01_phyldbs,cw_p01_03,cw_op01_01,cw_od01 10:cw_p01_phyldbs,cw_p01_03,cw_op01_01 (1 Reply)
Discussion started by: Optimus_P
1 Replies

2. Solaris

Server - 2 disks - How to mirror

I hope I am posting in the correct forum. I have a server - which I am installing solaris 9 on. The server currently has 2 disks. I wish to run solaris 9 on one, and use the other as a mirror for the first one. ie. If the first one should ever fail, then I can swap to the mirror and just... (18 Replies)
Discussion started by: frustrated1
18 Replies

3. Solaris

ZFS Mirror versus Hardware Mirror

I've looked a little but haven't found a solid answer, assuming there is one. What's better, hardware mirroring or ZFS mirroring? Common practice for us was to use the raid controllers on the Sun x86 servers. Now we've been using ZFS mirroring since U6. Any performance difference? Any other... (3 Replies)
Discussion started by: Lespaul20
3 Replies

4. Infrastructure Monitoring

zfs - migrate from pool to pool

Here are the details. cnjr-opennms>root$ zfs list NAME USED AVAIL REFER MOUNTPOINT openpool 20.6G 46.3G 35.5K /openpool openpool/ROOT 15.4G 46.3G 18K legacy openpool/ROOT/rds 15.4G 46.3G 15.3G / openpool/ROOT/rds/var 102M ... (3 Replies)
Discussion started by: pupp
3 Replies

5. Solaris

What is mirror and sub mirror in RAID -1 SVM

Hi , I am new to SVM .when i try to learn RAID 1 , first they are creating two RAID 0 strips through metainit d51 1 1 c0t0d0s2 metainit d52 1 1 c1t0d0s2 In the next step metainit d50 -m d51 d50: Mirror is setup next step is metaattach d50 d52 d50 : submirror d52 is... (7 Replies)
Discussion started by: vr_mari
7 Replies

6. Solaris

ZFS - list of disks used in a pool

Hi guys, We had created a pool as follows: zpool create filing_pool raidz c1t2d0 c1t3d0 ........ Due to some requirement, we need to destroy the pool and re-create another one. We wish to know now which disks have been included in the filing_pool, how do we list the disks used to create... (2 Replies)
Discussion started by: frum
2 Replies

7. Solaris

not able to use pool

i have this pool1 on my sun4u sparc machine bash-3.00# zpool get all pool1 NAME PROPERTY VALUE SOURCE pool1 size 292G - pool1 used 76.5K - pool1 available 292G - pool1 capacity 0% -... (1 Reply)
Discussion started by: Sojourner
1 Replies

8. HP-UX

What is the difference between DRD and Root Mirror Disk using LVM mirror ?

what is the difference between DRD and Root Mirror Disk using LVM mirror ? (3 Replies)
Discussion started by: maxim42
3 Replies

9. Solaris

How to detach root mirror pool?

I have to do patching in single user mode in solaris 10 zfs root pool. Before that I have to detach the root mirror pool so that if patching fails then I can boot from detached root mirror pool. Please let me know how can I detach root pool bash-3.2# zpool status pool: rpool state: ONLINE... (5 Replies)
Discussion started by: hb00
5 Replies
vgchgid(1M)															       vgchgid(1M)

NAME
vgchgid - modify the Volume Group ID (VGID) on a given set of physical devices SYNOPSIS
PhysicalVolumePath [PhysicalVolumePath] ... DESCRIPTION
The command is designed to change the LVM Volume Group ID (VGID) on a supplied set of disks. will work with any type of storage, but it is primarily targeted at disk arrays that are able to create "snapshots" or "clones" of mirrored LUNs. accepts a set of raw physical devices and ensures that they all belong to the same volume group, before altering the VGID (see section). The same VGID is set on all the disks and it should be noted that in cases of multi-PV volume groups, all the physical volumes should be supplied in a single invocation of the command. Options recognizes the following options and arguments: PhysicalVolumePath The raw devices path name of a physical volume. Background Some storage subsystems have a feature which allows a user to split off a set of mirror copies of physical storage (termed or just as LVM splits off logical volumes with the command. As the result of the "split," the split-off devices will have the same VGID as the original disks. is needed to modify the VGID on the BCV devices. Once the VGID has been altered, the BCV disks can be imported into a new volume group by using WARNINGS
Once the VGID has been changed, the original VGID is lost until a disk device is re-mirrored with the original devices. If is used on a subset of disk devices (for example, two out of four disk devices), the two groups of disk devices would not be able to be imported into the same volume group since they have different VGIDs on them. The solution is to re-mirror all four of the disk devices and re-run on all four BCV devices at the same time, and then use to import them into the same new volume group. If a disk is newly added to an existing volume group and no subsequent LVM operations has been performed to alter the structures (in other words, operations which perform an automated vgcfgbackup(1M)); then it is possible a subsequent will fail. It will report that the disk does not belong to the volume group. This may be overcome by performing a structure changing operation on the volume group (for example, using It is the system administrator's responsibility to make sure that the devices provided in the command line are all Business Copy volumes of the existing standard physical volumes and are in the ready state and writable. Mixing the standard and BC volumes in the same volume group can cause data corruption. RETURN VALUE
returns the following values: 0 VGID was modified with no error 1 VGID was not modified EXAMPLES
An example showing how might be used: 1. The system administrator uses the following commands to create the Business Continuity (BCV or BC) copy: 1) For EMC Symmetrix disks, the commands are and 2) For XP disk array, the commands are and Three BCV disks are created. 2. Change the VGID on the BCV disks. 3. Make a new volume group using the BCV disks. This step can be skipped as the group file will be created automatically. If the file is manually created it will have different major and minor numbers (see lvm(7)). 4. Import the BCV disks into the new volume group. 5. Activate the new volume group. 6. Backup the new volume group's LVM data structure. 7. Mount the associated logical volumes. SEE ALSO
vgimport(1M), vgscan(1M), vgcfgbackup(1M). vgchgid(1M)