Hi
I have 2 ZFS filesystems (Sun M3000 server connected to Clariion external storage vie 2 X HBA's) - ZFS filesytems (1 X mirror - 100GB X2) and the 2nd ZFS is 2 concatenated disks - 100GB + 50GB.
Both ZPOOLS are reporting CKSUM errors only - no READ or WRITE errors. I have cleared the errors a few times, but they re-appear soon after.
The /var/adm/messages has the following errors....
Any suggestions would be of great help!
thanks
Sam - Durban, South Africa
Last edited by radoulov; 09-05-2011 at 05:04 PM..
Reason: Code tags!
I know I can run the cksum command for multiple files in a directory and send the results to a new file.
EX.)
# cd /usr
# cksum *_ex* > /tmp/cksumusr.txt
But I can't figure out how to run this command on multiple files in all directories on drive. Is it possible to do this, without having... (2 Replies)
hello all.
I'm not asking about the algorithm - or how it goes about computing the checksum - I'm asking how it views/looks at the files it does the cksum on.
For instance:
Say you had a directory named "dir_A"
And within this directory you had some files.
So:
dir_A
- file1
-... (5 Replies)
Hi there,
I have a query about cksum. I'm running a script on the Unix box and in a script the cksum result differs from when I run it manually. As far as I can see the file is not being changed, is there any other times that the cksum would be different. (4 Replies)
Hi,
I have a working script, well it works on my machine but when I try it on others the cksum section does not work properly (I know the scripting is not of a high quality but I'm just trying to get it working)
Heres the script:
#!/bin/sh
case $# in
0) echo "usage: enshar filename... (7 Replies)
hi,
I am trying to use the cksum feature in unix. when i make a call to it i get returned something along the lines of:
4603435 14 file3
how do i get the first part of this response only; i.e:
4603435
I'm trying to use at a way without the use of sed and creating temp... (4 Replies)
Hi,
On what factors does the cksum depend.
If i build 2 machines exactly the same, then can i get the checksum of 2 compiled files same.
Thanks (3 Replies)
Hi guys,
I have a service directory with a lot of files in.
I have to cksum the whole directory and compare it to a release note document.
However the problem I have is the files are listed in different lines when running cksum as they are in the release doc. Therefore cksum shows... (1 Reply)
Hi,
I try to mount an external USB HD on a solaris 10 without any success.
Machine hardware: i86pc
OS version: 5.10
Processor type: i386
Hardware: i86pc
The HD is a zfs, but I installed this with a Ubuntu 8.10.
iostat -En displays this:
--> so the system... (0 Replies)
Hi all,
So I have a binary file and I need to generate an expected EEPROM checksum for it. Ideally, I would like to input the file (with the path) and output a computed checksum. Ive been using (cksum file1) with no avail and I was just curious as to whether there is such thing as EEPROM cksum,... (1 Reply)
Discussion started by: TeamUSA
1 Replies
LEARN ABOUT XFREE86
fp
fp(7d) Devices fp(7d)NAME
fp - Sun Fibre Channel port driver
DESCRIPTION
The fp driver is a Sun fibre channel nexus driver that enables fibre channel topology discovery, device discovery, fibre channel adapter
port management and other capabilities through well-defined fibre channel adapter driver interfaces.
The fp driver requires the presence of a fabric name server in fabric and public loop topologies to discover fibre channel devices. In pri-
vate loop topologies, the driver discovers devices by performing PLOGI to all valid AL_PAs, provided that devices do not participate in
LIRP and LILP stages of loop initialization.
CONFIGURATION
The fp driver is configured by defining properties in the fp.conf file. The fp driver supports the following properties:
mpxio-disable
Solaris I/O multipathing is enabled or disabled on fibre channel devices with the mpxio-disable property. Specifying mpxio-disable="no"
activates I/O multipathing, while mpxio-disable="yes" disables the feature.
Solaris I/O multipathing may be enabled or disabled on a per port basis. Per port settings override the global setting for the specified
ports. The following example shows how to disable multipathing on port 0 whose parent is /pci@8,600000/SUNW,qlc@4:
name="fp" parent="/pci@8,600000/SUNW,qlc@4" port=0
mpxio-disable="yes";
manual_configuration_only
Automatic configuration of SCSI devices in the fabric is enabled by default and thus allows all devices discovered in the SAN zone to be
enumerated in the kernel's device tree automatically. The manual_configuration_only property may be configured to disable the default
behavior and force the manual configuration of the devices in the SAN. Specifying manual_configuration_only=1 disables the automatic con-
figuration of devices.
FILES
/kernel/drv/fp
32-bit ELF kernel driver (x86)
/kernel/drv/amd64/fp
64-bit ELF kernel driver (x86)
/kernel/drv/sparcv9/fp
64-bit ELF kernel driver (SPARC)
/kernel/drv/fp.conf
fp driver configuration file.
ATTRIBUTES
See attributes(5) for descriptions of the following attributes:
+-----------------------------+-----------------------------+
| ATTRIBUTE TYPE | ATTRIBUTE VALUE |
+-----------------------------+-----------------------------+
|mpxio-disable |Unstable |
+-----------------------------+-----------------------------+
|manual_configuration_only |Obsolete |
+-----------------------------+-----------------------------+
|Availability |SUNWfctl |
+-----------------------------+-----------------------------+
SEE ALSO cfgadm_fp(1M), prtconf(1M), stmsboot(1M), driver.conf(4), attributes(5), fcp(7D), fctl(7D), scsi_vhci(7D)
Writing Device Drivers
Fibre Channel Physical and Signaling Interface (FC-PH) ANSI X3.230: 1994
Fibre Channel Generic Services (FC-GS-2) Project 1134-D
Fibre Channel Arbitrated Loop (FC-AL) ANSI X3.272-1996
Fibre Channel Protocol for SCSI (FCP) ANSI X3.269-1996
SCSI-3 Architecture Model (SAM) Fibre Channel Private Loop SCSI Direct Attach (FC-PLDA) ANSI X3.270-1996
SCSI Direct Attach (FC-PLDA) ANSI X3.270-1996
SCSI Direct Attach (FC-PLDA) NCITS TR-19:1998
Fabric Loop Attachment (FC-FLA), NCITS TR-20:1998
SunOS 5.10 2 Dec 2004 fp(7d)